Stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional finite element analysis.

IF 1.8 Q3 MEDICINE, RESEARCH & EXPERIMENTAL European Journal of Translational Myology Pub Date : 2024-02-16 DOI:10.4081/ejtm.2024.12170
Faeze Masoomi, Farhang Mahboub
{"title":"Stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional finite element analysis.","authors":"Faeze Masoomi, Farhang Mahboub","doi":"10.4081/ejtm.2024.12170","DOIUrl":null,"url":null,"abstract":"<p><p>Success/failure of dental implants depends on stress transfer and distribution at the bone-implant interface. This study aimed to assess the stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional (3D) finite element analysis (FEA). In this FEA, a geometric model of an edentulous maxilla, Zimmer screw-vent tantalum and solid titanium implants were modelled. Four models with the all-on-four concept were designed. The fifth model had 6 vertical implants (all-on-six). Two different implant types (porous tantalum and solid titanium) were modelled to yield a total of 10 models, and subjected to 200 N bilateral vertical load. Pattern of stress distribution and maximum von Mises stress values in cancellous and cortical bones around implants were analysed. In tantalum models, the effect of increasing the distal tilting of posterior implants was comparable to the effect of increasing the number of implants to 6 on von Mises stress values in cortical bone. However, in cancellous bone, the effect of increasing the tilting of posterior implants on stress was slightly greater than the effect of increasing the number of implants to 6. In solid titanium models, the effect of both of the abovementioned parameters was comparable on stress in cancellous bone; but in cortical bone, the effect of increasing the implant number was slightly greater on stress reduction. Despite similar pattern of stress distribution in bone around implants, higher maximum von Mises stress values around tantalum implants indicate higher stress transfer capacity of this type of implant to the adjacent bone, compared with solid titanium implants.</p>","PeriodicalId":46459,"journal":{"name":"European Journal of Translational Myology","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11017177/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Translational Myology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/ejtm.2024.12170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

Success/failure of dental implants depends on stress transfer and distribution at the bone-implant interface. This study aimed to assess the stress distribution pattern in all-on-four maxillary restorations supported by porous tantalum and solid titanium implants using three-dimensional (3D) finite element analysis (FEA). In this FEA, a geometric model of an edentulous maxilla, Zimmer screw-vent tantalum and solid titanium implants were modelled. Four models with the all-on-four concept were designed. The fifth model had 6 vertical implants (all-on-six). Two different implant types (porous tantalum and solid titanium) were modelled to yield a total of 10 models, and subjected to 200 N bilateral vertical load. Pattern of stress distribution and maximum von Mises stress values in cancellous and cortical bones around implants were analysed. In tantalum models, the effect of increasing the distal tilting of posterior implants was comparable to the effect of increasing the number of implants to 6 on von Mises stress values in cortical bone. However, in cancellous bone, the effect of increasing the tilting of posterior implants on stress was slightly greater than the effect of increasing the number of implants to 6. In solid titanium models, the effect of both of the abovementioned parameters was comparable on stress in cancellous bone; but in cortical bone, the effect of increasing the implant number was slightly greater on stress reduction. Despite similar pattern of stress distribution in bone around implants, higher maximum von Mises stress values around tantalum implants indicate higher stress transfer capacity of this type of implant to the adjacent bone, compared with solid titanium implants.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用三维有限元分析法研究由多孔钽和实心钛种植体支撑的全牙列上颌修复体的应力分布模式。
牙科种植体的成败取决于骨-种植体界面的应力传递和分布。本研究旨在利用三维(3D)有限元分析(FEA)评估由多孔钽和实心钛种植体支撑的上颌全牙列修复体的应力分布模式。在该有限元分析中,对无牙上颌骨的几何模型、Zimmer 螺钉孔钽和固态钛种植体进行了建模。设计了四种具有 "全对四 "概念的模型。第五个模型有 6 个垂直种植体(全对六)。对两种不同类型的种植体(多孔钽和固态钛)共 10 个模型进行建模,并承受 200 N 的双侧垂直负荷。分析了植入物周围松质骨和皮质骨的应力分布模式和最大 von Mises 应力值。在钽模型中,增加后植入体远端倾斜度对皮质骨中 von Mises 应力值的影响与增加植入体数量至 6 个对皮质骨中 von Mises 应力值的影响相当。然而,在松质骨中,增加后植入体倾斜度对应力的影响略大于增加植入体数量至 6 个的影响。在固体钛模型中,上述两个参数对松质骨应力的影响相当;但在皮质骨中,增加植入体数量对应力降低的影响略大。尽管种植体周围骨质的应力分布模式相似,但钽种植体周围的最大冯米塞斯应力值较高,这表明与固态钛种植体相比,这种类型的种植体向邻近骨质传递应力的能力更强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Journal of Translational Myology
European Journal of Translational Myology MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
3.30
自引率
27.30%
发文量
74
审稿时长
10 weeks
期刊最新文献
Comparing Percutaneous Coronary Intervention and Coronary Artery Bypass Graft in Treatment of Non-ST-segment Elevation Acute Coronary Syndromes: A Systematic Review and Meta-Analysis Study. Low level laser therapy and rheumatoid arthritis: a systematic review and meta-analysis study. Vitamin D receptor gene polymorphisms in patients with relapsing multiple sclerosis. Efficacy of electrical stimulation of the zygomaticus muscle in complete facial paralysis: evidence from facial grading and automated image analysis. Deceleration of denervated facial muscle atrophy through functional electrical stimulation: a sonographic quantification in patients with facial nerve paralysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1