Performance tests of a portable thyroid radioiodine meter

Q1 Health Professions Radiation Medicine and Protection Pub Date : 2024-03-01 DOI:10.1016/j.radmp.2024.02.002
Zeshu Li , Zhijie Yang , Fei Tuo , Shuo Wang , Qianqian Zhou , Juncheng Liang
{"title":"Performance tests of a portable thyroid radioiodine meter","authors":"Zeshu Li ,&nbsp;Zhijie Yang ,&nbsp;Fei Tuo ,&nbsp;Shuo Wang ,&nbsp;Qianqian Zhou ,&nbsp;Juncheng Liang","doi":"10.1016/j.radmp.2024.02.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To evaluate the effectiveness of a portable thyroid radioiodine meter in on-site monitoring to enhance the monitoring precision of radioiodine inhaled by nuclear medicine staff and patients.</p></div><div><h3>Methods</h3><p>A portable thyroid radioiodine meter was developed to measure the <sup>131</sup>I activity in the thyroid. Performance tests of the portable thyroid radioiodine meter were conducted using calibration sources and testing methodologies adhering to national metrological standards.</p></div><div><h3>Results</h3><p>The thyroid radioiodine meter exhibited integral non-linearity, 8-h measurement stability, measurement linearity, and an energy resolution of 0.42%, 1.05%, 1.56%, and 7.11%, respectively for <sup>137</sup>Cs at 661.66 ​keV. Additionally, its minimum detectable activity for <sup>131</sup>I at 364.49 ​keV was approximately 22 Bq (10 ​min).</p></div><div><h3>Conclusion</h3><p>The developed thyroid radioiodine meter features elevated performance and great potential for application in nuclear medicine and monitoring of responses to nuclear or radiological emergencies.</p></div>","PeriodicalId":34051,"journal":{"name":"Radiation Medicine and Protection","volume":"5 1","pages":"Pages 53-58"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666555724000042/pdfft?md5=5c420579f044ef0186d9423aed45557f&pid=1-s2.0-S2666555724000042-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Medicine and Protection","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666555724000042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluate the effectiveness of a portable thyroid radioiodine meter in on-site monitoring to enhance the monitoring precision of radioiodine inhaled by nuclear medicine staff and patients.

Methods

A portable thyroid radioiodine meter was developed to measure the 131I activity in the thyroid. Performance tests of the portable thyroid radioiodine meter were conducted using calibration sources and testing methodologies adhering to national metrological standards.

Results

The thyroid radioiodine meter exhibited integral non-linearity, 8-h measurement stability, measurement linearity, and an energy resolution of 0.42%, 1.05%, 1.56%, and 7.11%, respectively for 137Cs at 661.66 ​keV. Additionally, its minimum detectable activity for 131I at 364.49 ​keV was approximately 22 Bq (10 ​min).

Conclusion

The developed thyroid radioiodine meter features elevated performance and great potential for application in nuclear medicine and monitoring of responses to nuclear or radiological emergencies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
便携式甲状腺放射性碘测定仪的性能测试
目的 评价便携式甲状腺放射性碘测量仪在现场监测中的有效性,以提高对核医学工作人员和患者吸入的放射性碘的监测精度。方法 研发了一种便携式甲状腺放射性碘测量仪,用于测量甲状腺中的131I活度。结果甲状腺放射性碘仪在 661.66 keV 的 137Cs 测量中表现出积分非线性、8 h 测量稳定性、测量线性和能量分辨率分别为 0.42%、1.05%、1.56% 和 7.11%。此外,该仪器在 364.49 keV 波长下对 131I 的最小检测活度约为 22 Bq(10 分钟)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Medicine and Protection
Radiation Medicine and Protection Health Professions-Emergency Medical Services
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
103 days
期刊最新文献
Dosimetry of automatic non-coplanar volumetric-modulated arc therapy for nasopharyngeal carcinoma Radioactivity concentration of 14C in the air of 14C urea breath test rooms and the resulting internal dose to medical staff Study on the detection efficiencies of liquid 99Tcm, 131I, and 18F in a well-type NaI(Tl) gamma spectrometer Role of heat shock protein in radiation-induced effect and related potential clinical application Artificial intelligence for chest X-ray image enhancement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1