Where does perceived control come from? A survey of a dormitory building across different operation modes in summer

IF 3.2 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Indoor and Built Environment Pub Date : 2024-02-14 DOI:10.1177/1420326x241232590
Dongyu Lu, Haiyan Yan, Guodong Yuan, Weichao Wang
{"title":"Where does perceived control come from? A survey of a dormitory building across different operation modes in summer","authors":"Dongyu Lu, Haiyan Yan, Guodong Yuan, Weichao Wang","doi":"10.1177/1420326x241232590","DOIUrl":null,"url":null,"abstract":"Prior studies have attributed the heightened positive thermal response during summer to perceived control. The process through which perceived control is cultivated in the built environment has been scarcely explored. A field study was conducted in a dormitory building operating successively in natural ventilation and mixed-mode in the cold region of China. A total of 922 valid samples were obtained. The data analysis indicated that the building’s operation mode impacted both perceived control and its influencing factors. In natural ventilation mode, occupants perceived less control than in mixed-mode, and perceived control was shaped by both thermal stimulus and exercised control. Conversely, in mixed-mode, the occupants’ perceived control was solely influenced by exercised control. Reflecting on this result, this study is the first to suggest a method for determining ‘perceived effectiveness’ by assessing occupants’ thermal sensations and preferences. Only air conditioning was perceived as effective, amplifying occupants’ perceived control, while other controls diminished it. In mixed-mode, control combinations incorporating air conditioning were judged to have perceived effectiveness. On this basis, further combining psychological adaptation with behavioural adaptation, active and passive technology was used to play the role of behavioural adaptation, and the upper limit of acceptable temperature for occupants was increased to 31.1°C.","PeriodicalId":13578,"journal":{"name":"Indoor and Built Environment","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor and Built Environment","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/1420326x241232590","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Prior studies have attributed the heightened positive thermal response during summer to perceived control. The process through which perceived control is cultivated in the built environment has been scarcely explored. A field study was conducted in a dormitory building operating successively in natural ventilation and mixed-mode in the cold region of China. A total of 922 valid samples were obtained. The data analysis indicated that the building’s operation mode impacted both perceived control and its influencing factors. In natural ventilation mode, occupants perceived less control than in mixed-mode, and perceived control was shaped by both thermal stimulus and exercised control. Conversely, in mixed-mode, the occupants’ perceived control was solely influenced by exercised control. Reflecting on this result, this study is the first to suggest a method for determining ‘perceived effectiveness’ by assessing occupants’ thermal sensations and preferences. Only air conditioning was perceived as effective, amplifying occupants’ perceived control, while other controls diminished it. In mixed-mode, control combinations incorporating air conditioning were judged to have perceived effectiveness. On this basis, further combining psychological adaptation with behavioural adaptation, active and passive technology was used to play the role of behavioural adaptation, and the upper limit of acceptable temperature for occupants was increased to 31.1°C.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
感知控制从何而来?对一栋宿舍楼夏季不同运行模式的调查
先前的研究将夏季积极热反应的增强归因于感知控制。但对于建筑环境中感知控制的形成过程却鲜有探讨。我们在中国寒冷地区的一栋先后采用自然通风和混合模式的宿舍楼中进行了实地研究。共获得 922 个有效样本。数据分析表明,楼宇的运行模式对感知控制及其影响因素均有影响。在自然通风模式下,居住者感知到的控制比混合模式下少,感知到的控制受热刺激和运动控制的影响。相反,在混合模式下,居住者的控制感知仅受行使控制的影响。考虑到这一结果,本研究首次提出了通过评估居住者的热感觉和偏好来确定 "感知有效性 "的方法。只有空调被认为是有效的,扩大了居住者的感知控制,而其他控制则降低了居住者的感知控制。在混合模式中,包含空调的控制组合被认为具有感知效果。在此基础上,进一步将心理适应与行为适应相结合,利用主动和被动技术发挥行为适应的作用,将居住者可接受的温度上限提高到 31.1°C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor and Built Environment
Indoor and Built Environment 环境科学-工程:环境
CiteScore
6.40
自引率
25.00%
发文量
130
审稿时长
2.6 months
期刊介绍: Indoor and Built Environment publishes reports on any topic pertaining to the quality of the indoor and built environment, and how these might effect the health, performance, efficiency and comfort of persons living or working there. Topics range from urban infrastructure, design of buildings, and materials used to laboratory studies including building airflow simulations and health effects. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics Synthesis and performance study of biomass-based suppressant and its application in radioactive aerosol sedimentation Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1