[Bond strength of metal brackets to enamel with a Russian adhesive complex: an in vitro study].

Q4 Medicine Stomatologiya Pub Date : 2024-01-01 DOI:10.17116/stomat20241030115
N S Tuturov, A M Khasan, F S Rusanov, I Katbeh, D S Bulycheva, A Saleh
{"title":"[Bond strength of metal brackets to enamel with a Russian adhesive complex: an in vitro study].","authors":"N S Tuturov, A M Khasan, F S Rusanov, I Katbeh, D S Bulycheva, A Saleh","doi":"10.17116/stomat20241030115","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The era of using adhesives to fix brackets began in the 70s of the last century. There are eight generations of foreign-made adhesive systems for the restoration of teeth. However, until now, in orthodontics, the development of domestic adhesive systems with improved properties of adhesion of brackets to tooth enamel still important, especially in the posterior teeth.</p><p><strong>Objective: </strong>The purpose of this work was to study the shear strength of fifth generation domestic adhesive between metal brackets and the enamel of molar teeth in laboratory conditions.</p><p><strong>Material and methods: </strong>The study included 17 specimens of extracted maxillary molars embedded in acrylic resin blocks. Brackets from G&H Orthodontics (G&H Wire Company, USA) were fixed to the tooth enamel using the domestic Compofix (ortho) set. The enamel was treated with etching gel (37% phosphoric acid) for 30 seconds. Then the gel was washed off with water and the surface of the enamel was thoroughly dried. A primer was applied to the prepared surface with an applicator, inflated with a weak air flow for 5-10 seconds and photopolymerized for 20 seconds. The surface of the bracket was treated with degreaser, then a thin layer of adhesive was applied, and the sample was fixed to the enamel. Excess material was removed with an applicator. The samples were photopolymerized for 20 sec. Then, the shear bond strength of the adhesive was determined according to the method of GOST 31574-2012 on a (Zwick/Roell Z010 testing machine, Zwick, Germany).</p><p><strong>Results: </strong>The shear strength of the adhesive joint obtained during the test is 13.54±1.01 MPa, the average value of the index of adhesive residues on the surface of the bracket was 23%±4%, which corresponds to the standard average values according to GOST.</p><p><strong>Conclusion: </strong>The tested domestic adhesive system of the fifth generation can be recommended for the practical work of an orthodontist.</p>","PeriodicalId":35887,"journal":{"name":"Stomatologiya","volume":"103 1","pages":"5-7"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stomatologiya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/stomat20241030115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The era of using adhesives to fix brackets began in the 70s of the last century. There are eight generations of foreign-made adhesive systems for the restoration of teeth. However, until now, in orthodontics, the development of domestic adhesive systems with improved properties of adhesion of brackets to tooth enamel still important, especially in the posterior teeth.

Objective: The purpose of this work was to study the shear strength of fifth generation domestic adhesive between metal brackets and the enamel of molar teeth in laboratory conditions.

Material and methods: The study included 17 specimens of extracted maxillary molars embedded in acrylic resin blocks. Brackets from G&H Orthodontics (G&H Wire Company, USA) were fixed to the tooth enamel using the domestic Compofix (ortho) set. The enamel was treated with etching gel (37% phosphoric acid) for 30 seconds. Then the gel was washed off with water and the surface of the enamel was thoroughly dried. A primer was applied to the prepared surface with an applicator, inflated with a weak air flow for 5-10 seconds and photopolymerized for 20 seconds. The surface of the bracket was treated with degreaser, then a thin layer of adhesive was applied, and the sample was fixed to the enamel. Excess material was removed with an applicator. The samples were photopolymerized for 20 sec. Then, the shear bond strength of the adhesive was determined according to the method of GOST 31574-2012 on a (Zwick/Roell Z010 testing machine, Zwick, Germany).

Results: The shear strength of the adhesive joint obtained during the test is 13.54±1.01 MPa, the average value of the index of adhesive residues on the surface of the bracket was 23%±4%, which corresponds to the standard average values according to GOST.

Conclusion: The tested domestic adhesive system of the fifth generation can be recommended for the practical work of an orthodontist.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[金属托架与珐琅质与俄罗斯复合粘合剂的粘合强度:体外研究]。
背景:使用粘合剂固定托槽的时代始于上世纪 70 年代。国外生产的牙齿修复用粘合剂系统已有八代。然而,直到现在,在正畸学中,开发具有更好的托槽与牙釉质粘附性能的国产粘接剂系统仍然很重要,尤其是在后牙方面:这项工作的目的是在实验室条件下研究第五代国产粘合剂在金属支架和磨牙珐琅质之间的剪切强度:这项研究包括 17 个嵌入丙烯酸树脂块的上颌臼齿拔牙标本。使用国产 Compofix(ortho)套装将 G&H Orthodontics(美国 G&H Wire Company)公司生产的托槽固定在牙釉质上。用蚀刻凝胶(37% 磷酸)处理牙釉质 30 秒钟。然后用水洗掉凝胶,彻底干燥珐琅质表面。用涂抹器在制备好的表面涂上底漆,用弱气流充气 5-10 秒,然后光聚合 20 秒。用脱脂剂处理支架表面,然后涂上一层薄薄的粘合剂,将样品固定在珐琅质上。用涂抹器去除多余的材料。样品经过 20 秒的光聚合。然后,根据 GOST 31574-2012 方法,在一台(Zwick/Roell Z010 试验机,德国 Zwick 公司)上测定粘合剂的剪切粘接强度:结果:试验中获得的粘接强度为 13.54±1.01 MPa,支架表面粘合剂残留指数的平均值为 23%±4%,符合 GOST 标准的平均值:经测试的第五代国产粘合剂系统可推荐用于正畸医生的实际工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Stomatologiya
Stomatologiya Medicine-Medicine (all)
CiteScore
0.40
自引率
0.00%
发文量
93
期刊最新文献
[A clinical case of piloleiomyoma]. [Bond strength of metal brackets to enamel with a Russian adhesive complex: an in vitro study]. [Elimination of defects in the Schneiderian membrane during sinus lift operations]. [Evaluation of the efficiency of the method of biological feedback in complex therapy of patients with hypertonus of the chewing muscles]. [Features of medical care provision in the profile «Maxillofacial surgery» in the Southern Federal District of the Russian Federation].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1