EESIS-FR. French eCLIPs™ Efficacy and Safety Investigation of eCLIPs devices for intracranial Bifurcation Aneurysms. Mid Enrolment results.

IF 3 3区 医学 Q2 CLINICAL NEUROLOGY Journal of Neuroradiology Pub Date : 2024-02-24 DOI:10.1016/j.neurad.2024.01.078
Raphaël Blanc, on behalf on the EESIS-FR study group
{"title":"EESIS-FR. French eCLIPs™ Efficacy and Safety Investigation of eCLIPs devices for intracranial Bifurcation Aneurysms. Mid Enrolment results.","authors":"Raphaël Blanc,&nbsp;on behalf on the EESIS-FR study group","doi":"10.1016/j.neurad.2024.01.078","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and Methods</h3><p>eCLIPs eB is a unique device designed to retain coils and divert flow at a bifurcation aneurysm with 4 sizes to accommodate neck lengths to 12mm. French eCLIPs™ Efficacy and Safety Investigation (EESIS-FR) is an open label, prospective, historically controlled (vs. optimal performance criteria), multicentre, single-arm study trial partly funded by French HAS under its Forfait Innovation program to demonstrate safety and efficacy of eCLIPs for saccular, intracranial aneurysms, unruptured or previously ruptured (≥1 month since rupture and neurologically stable), arising at a bifurcation of Basilar Tip (BT) or Carotid Terminus (CT), with a minimal diameter of 5mm and a maximal diameter &lt;25mm, has a neck length of ≥4mm or dome:neck ratio &lt;2, branch artery diameters in the range of 1.5mm to 3.25mm.</p></div><div><h3>Results</h3><p>We report the first 60 patients (of a goal of 119) enrolled at 13 sites (opened on 26 particpating sites). Aneurysm characteristics: 26 BT, 34 CT, 15 recurrent after prior treatment, 9 previously ruptured. Aneurysm metrics are as follows (Table1):</p></div><div><h3>Safety</h3><p>Two patients (3.3%) had procedural safety events: one had small subarachnoid hemorrhage (microcatheter manipulation) at the bifurcation and 1 had spinal ischemia due to access-catheter trauma to vertebral artery. Thirty-eight patients have follow-up at 6 months, 11 patients ≥12 months. No subsequent safety events occurred through follow-up; only 1 patient (noted above) had MRS &gt;2.</p></div><div><h3>Efficacy</h3><p>modified Raymond Roy Occlusion Classification (mRROC) at each follow-up:</p></div><div><h3>Conclusion</h3><p>EESIS-FR is the first prospective analysis of eCLIPs eB, showing in preliminary results acceptable safety and efficacy profiles. The complete results of the full cohort of 119 patients are necessary to finalize these conclusions.</p></div>","PeriodicalId":50115,"journal":{"name":"Journal of Neuroradiology","volume":"51 2","pages":"Page 115"},"PeriodicalIF":3.0000,"publicationDate":"2024-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0150986124000889","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and Methods

eCLIPs eB is a unique device designed to retain coils and divert flow at a bifurcation aneurysm with 4 sizes to accommodate neck lengths to 12mm. French eCLIPs™ Efficacy and Safety Investigation (EESIS-FR) is an open label, prospective, historically controlled (vs. optimal performance criteria), multicentre, single-arm study trial partly funded by French HAS under its Forfait Innovation program to demonstrate safety and efficacy of eCLIPs for saccular, intracranial aneurysms, unruptured or previously ruptured (≥1 month since rupture and neurologically stable), arising at a bifurcation of Basilar Tip (BT) or Carotid Terminus (CT), with a minimal diameter of 5mm and a maximal diameter <25mm, has a neck length of ≥4mm or dome:neck ratio <2, branch artery diameters in the range of 1.5mm to 3.25mm.

Results

We report the first 60 patients (of a goal of 119) enrolled at 13 sites (opened on 26 particpating sites). Aneurysm characteristics: 26 BT, 34 CT, 15 recurrent after prior treatment, 9 previously ruptured. Aneurysm metrics are as follows (Table1):

Safety

Two patients (3.3%) had procedural safety events: one had small subarachnoid hemorrhage (microcatheter manipulation) at the bifurcation and 1 had spinal ischemia due to access-catheter trauma to vertebral artery. Thirty-eight patients have follow-up at 6 months, 11 patients ≥12 months. No subsequent safety events occurred through follow-up; only 1 patient (noted above) had MRS >2.

Efficacy

modified Raymond Roy Occlusion Classification (mRROC) at each follow-up:

Conclusion

EESIS-FR is the first prospective analysis of eCLIPs eB, showing in preliminary results acceptable safety and efficacy profiles. The complete results of the full cohort of 119 patients are necessary to finalize these conclusions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EESIS-FR。法国 eCLIPs™ eCLIPs 装置治疗颅内分叉动脉瘤的疗效和安全性调查。中期注册结果。
简介和方法seCLIPs eB 是一种独特的装置,设计用于在分叉动脉瘤处保留线圈和分流血流,有 4 种尺寸,可适应长达 12 毫米的动脉瘤颈。法国 eCLIPs™ 疗效和安全性调查(EESIS-FR)是一项开放标签、前瞻性、历史对照(与最佳性能标准对比)、多中心研究。法国 eCLIPs™ 疗效和安全性调查(EESIS-FR)是一项开放标签、前瞻性、历史对照(与最佳性能标准对比)、多中心、单臂研究试验,由法国 HAS 在其 Forfait Innovation 计划下提供部分资金,以证明 eCLIPs 治疗颅内囊状动脉瘤的安全性和有效性;25毫米,颈长≥4毫米或圆顶:颈部比值为 2,分支动脉直径在 1.5mm 至 3.25mm 之间。结果我们报告了在 13 个地点(在 26 个参与地点开刀)登记的首批 60 名患者(目标人数为 119 名)的情况。动脉瘤特征:26 个 BT,34 个 CT,15 个先前治疗后复发,9 个先前破裂。动脉瘤指标如下(表1):安全性2名患者(3.3%)发生了手术安全事件:1名患者在分叉处发生了小量蛛网膜下腔出血(微导管操作),1名患者由于入路导管创伤椎动脉而导致脊髓缺血。38名患者随访6个月,11名患者随访≥12个月。每次随访时的疗效改良雷蒙德-罗伊闭塞分类(mRROC):结论EESIS-FR是对eCLIPs eB进行的首次前瞻性分析,初步结果显示安全性和疗效均可接受。要得出最终结论,还需要 119 例患者的完整结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Neuroradiology
Journal of Neuroradiology 医学-核医学
CiteScore
6.10
自引率
5.70%
发文量
142
审稿时长
6-12 weeks
期刊介绍: The Journal of Neuroradiology is a peer-reviewed journal, publishing worldwide clinical and basic research in the field of diagnostic and Interventional neuroradiology, translational and molecular neuroimaging, and artificial intelligence in neuroradiology. The Journal of Neuroradiology considers for publication articles, reviews, technical notes and letters to the editors (correspondence section), provided that the methodology and scientific content are of high quality, and that the results will have substantial clinical impact and/or physiological importance.
期刊最新文献
MRI management of NMOSD and MOGAD: Proposals from the French Expert Group NOMADMUS. Impact of cerebral collateral recycle status on clinical outcomes in elderly patients with endovascular stroke treatment. The ARIANES initiative: A vision for a structured regional MRI network in the Hauts-de-France. The art and agony of AI in neuroradiology. White matter hyperintensities regress at a high rate at three months after minor ischemic stroke or transient ischemic attack.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1