Thermohydraulic performance parameter based experimental investigation of frustum shaped roughened solar air heater

Dharam Singh, Vikash Kumar
{"title":"Thermohydraulic performance parameter based experimental investigation of frustum shaped roughened solar air heater","authors":"Dharam Singh, Vikash Kumar","doi":"10.1177/09576509241227754","DOIUrl":null,"url":null,"abstract":"An outdoor experimental investigation was conducted to explore the thermohydraulic characteristic (Nusselt no. and friction factor) of artificial roughened solar air heater (ARSAH) having frustrum shaped roughened element on absorber plate. Data were recorded and further processed to generate Nusselt number and friction factor correlation to predict the effect of flow and roughness parameter on performance of ARSAH. The investigation was conducted by varying Reynolds number in range of 2500–12,500. Dimensionless parameter for Frustrum shaped roughness was relative frustum height (e/D<jats:sub>h</jats:sub>) from 0.013 to 0.054, relative frustum pitch (p/e) from 8 to 14, Relative frustum height to base diameter (e/d<jats:sub>1</jats:sub>) from 0.37 to 0.75, relative frustum diametral ratio (d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub>) from 1 to 3. Maximum performance for ARSAH was obtained corresponding to the optimum value of flow and geometric parameter. The geometric orientation of the proposed roughness geometry produced tremendous rise in Nu with an acceptable rise in friction (f). Maximum enhancement in Nu for varying p/e, e/D<jats:sub>h</jats:sub>, e/d<jats:sub>1</jats:sub>, and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> was, 4.58, 5.21, 6.62 and 6.09 times and that of friction was 5.59, 4.69, 4.92 and 4.66 times respectively over conventional SAH. Maximum Thermohydraulic performance was 3.7, 3.6, 3.9 and 3.8 at p/e = 12, e/D<jats:sub>h</jats:sub> = 0.054, e/d<jats:sub>1</jats:sub> = 0.75 and d<jats:sub>1</jats:sub>/d<jats:sub>2</jats:sub> = 3.","PeriodicalId":20705,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09576509241227754","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An outdoor experimental investigation was conducted to explore the thermohydraulic characteristic (Nusselt no. and friction factor) of artificial roughened solar air heater (ARSAH) having frustrum shaped roughened element on absorber plate. Data were recorded and further processed to generate Nusselt number and friction factor correlation to predict the effect of flow and roughness parameter on performance of ARSAH. The investigation was conducted by varying Reynolds number in range of 2500–12,500. Dimensionless parameter for Frustrum shaped roughness was relative frustum height (e/Dh) from 0.013 to 0.054, relative frustum pitch (p/e) from 8 to 14, Relative frustum height to base diameter (e/d1) from 0.37 to 0.75, relative frustum diametral ratio (d1/d2) from 1 to 3. Maximum performance for ARSAH was obtained corresponding to the optimum value of flow and geometric parameter. The geometric orientation of the proposed roughness geometry produced tremendous rise in Nu with an acceptable rise in friction (f). Maximum enhancement in Nu for varying p/e, e/Dh, e/d1, and d1/d2 was, 4.58, 5.21, 6.62 and 6.09 times and that of friction was 5.59, 4.69, 4.92 and 4.66 times respectively over conventional SAH. Maximum Thermohydraulic performance was 3.7, 3.6, 3.9 and 3.8 at p/e = 12, e/Dh = 0.054, e/d1 = 0.75 and d1/d2 = 3.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于热水力学性能参数的挫面粗化太阳能空气加热器实验研究
通过室外实验研究,探索了在吸收板上具有沮渠形粗糙元件的人工粗糙化太阳能空气加热器(ARSAH)的热液压特性(努塞尔特数和摩擦因数)。对数据进行记录和进一步处理,生成相关的努塞尔特数和摩擦因数,以预测流动和粗糙度参数对 ARSAH 性能的影响。研究在 2500-12500 雷诺数范围内进行。相对挫面高度 (e/Dh) 从 0.013 到 0.054,相对挫面间距 (p/e) 从 8 到 14,相对挫面高度与底面直径 (e/d1) 从 0.37 到 0.75,相对挫面直径比 (d1/d2) 从 1 到 3。所建议的粗糙度几何形状的几何方向产生了巨大的 Nu 值增长,同时摩擦力 (f) 也有可接受的增长。与传统的 SAH 相比,在 p/e、e/Dh、e/d1 和 d1/d2 变化时,Nu 的最大提升分别为 4.58、5.21、6.62 和 6.09 倍,摩擦的最大提升分别为 5.59、4.69、4.92 和 4.66 倍。当 p/e = 12、e/Dh = 0.054、e/d1 = 0.75 和 d1/d2 = 3 时,最大热液压性能分别为 3.7、3.6、3.9 和 3.8。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.30
自引率
5.90%
发文量
114
审稿时长
5.4 months
期刊介绍: The Journal of Power and Energy, Part A of the Proceedings of the Institution of Mechanical Engineers, is dedicated to publishing peer-reviewed papers of high scientific quality on all aspects of the technology of energy conversion systems.
期刊最新文献
Studies on fuels and engine attributes powered by bio-diesel and bio-oil derived from stone apple seed (Aegle marmelos) for bioenergy Analysis of the aerothermal performance of modern commercial high-pressure turbine rotors using different levels of fidelity Analytical modeling and performance improvement of an electric two-stage centrifugal compressor for fuel cell vehicles Investigations into rubbing wear behavior of honeycomb land against labyrinth fin with periodic-cell model Secondary air induced flow structures and their interplay with the temperature field in fixed bed combustors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1