An In Vitro Comparative Study of the Push-out Bond Strengths of Various Endodontic Sealers to Radicular Dentin

Mohamed Abdelaziz El Sayed, Safiya Saeed Alderei
{"title":"An In Vitro Comparative Study of the Push-out Bond Strengths of Various Endodontic Sealers to Radicular Dentin","authors":"Mohamed Abdelaziz El Sayed, Safiya Saeed Alderei","doi":"10.4103/ijdr.ijdr_708_22","DOIUrl":null,"url":null,"abstract":"\n \n \n The bond strength of an endodontic sealer to the root dentin is an important factor in maintaining the integrity of the root canal seal. The present study aimed to assess the push-out bond strength of three endodontic sealers used with the single-cone obturation technique.\n \n \n \n The root canals of 40 central maxillary incisors were instrumented using ProTaper Universal NiTi rotary files. The roots were divided into 4 groups (N = 10) according to the type of root canal sealers: Group 1 (control group): AH Plus/Gutta-percha lateral condensation technique (LC); Group 2: AH Plus/Gutta-percha single-cone technique (SC); Group 3: GuttaFlow 2/SC; Group 4: Realseal SE/SC. After obturation, each tooth was prepared for push-out assessment. The total and sectional push-out bond strengths were measured and statistically analysed. Furthermore, failure modes were identified microscopically.\n \n \n \n The results indicated that samples in the first group showed the highest total and sectional bond strengths. Samples from other groups showed statistically similar total bond strengths. The highest sectional bond strength was found mainly in the apical root sections. Cohesive failure was predominant for the first group, whereas adhesive failure was predominant in the other groups.\n \n \n \n It could be concluded that the dentin bond strengths of the tested sealers used with the single-cone technique were nearly similar but lower than those of AH Plus/LC. The highest sectional bond strength was observed in the apical thirds. The failure mode was mostly cohesive for AH Plus/LC and adhesive for sealers used with the single-cone obturation technique.\n","PeriodicalId":13311,"journal":{"name":"Indian Journal of Dental Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ijdr.ijdr_708_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

The bond strength of an endodontic sealer to the root dentin is an important factor in maintaining the integrity of the root canal seal. The present study aimed to assess the push-out bond strength of three endodontic sealers used with the single-cone obturation technique. The root canals of 40 central maxillary incisors were instrumented using ProTaper Universal NiTi rotary files. The roots were divided into 4 groups (N = 10) according to the type of root canal sealers: Group 1 (control group): AH Plus/Gutta-percha lateral condensation technique (LC); Group 2: AH Plus/Gutta-percha single-cone technique (SC); Group 3: GuttaFlow 2/SC; Group 4: Realseal SE/SC. After obturation, each tooth was prepared for push-out assessment. The total and sectional push-out bond strengths were measured and statistically analysed. Furthermore, failure modes were identified microscopically. The results indicated that samples in the first group showed the highest total and sectional bond strengths. Samples from other groups showed statistically similar total bond strengths. The highest sectional bond strength was found mainly in the apical root sections. Cohesive failure was predominant for the first group, whereas adhesive failure was predominant in the other groups. It could be concluded that the dentin bond strengths of the tested sealers used with the single-cone technique were nearly similar but lower than those of AH Plus/LC. The highest sectional bond strength was observed in the apical thirds. The failure mode was mostly cohesive for AH Plus/LC and adhesive for sealers used with the single-cone obturation technique.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
各种牙髓密封剂与根管牙本质的推出粘接强度体外比较研究
根管封闭剂与根部牙本质的粘结强度是保持根管封闭完整性的一个重要因素。本研究旨在评估与单锥封闭技术一起使用的三种牙髓封闭剂的推出粘接强度。 使用 ProTaper 通用镍钛旋转锉对 40 颗上颌中切牙的根管进行了器械治疗。根据根管封闭剂的类型,牙根被分为 4 组(N = 10):第 1 组(对照组)第 1 组(对照组):AH Plus/Gutta-percha 侧向冷凝技术(LC);第 2 组:AH Plus/Gutta-percha 单向冷凝技术(LC):第 3 组:GuttaFlow 2/SC;第 4 组:Realseal SE/SC。封固后,准备对每颗牙齿进行推力评估。测量并统计分析了总的和断面的推出粘接强度。此外,还对失效模式进行了显微鉴定。 结果表明,第一组样品的总粘结强度和断面粘结强度最高。其他组的样品在统计上显示出相似的总粘结强度。断面粘接强度最高的主要是根尖部分。第一组主要是内聚失效,而其他组主要是粘合失效。 由此可以得出结论,使用单锥技术测试的封闭剂的牙本质粘接强度几乎相似,但低于 AH Plus/LC。根尖三分之二处的断面粘结强度最高。AH Plus/LC 的失效模式主要是内聚性的,而使用单锥封闭技术的封闭剂的失效模式主要是粘结性的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indian Journal of Dental Research
Indian Journal of Dental Research Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
80
审稿时长
38 weeks
期刊介绍: Indian Journal of Dental Research (IJDR) is the official publication of the Indian Society for Dental Research (ISDR), India section of the International Association for Dental Research (IADR), published quarterly. IJDR publishes scientific papers on well designed and controlled original research involving orodental sciences. Papers may also include reports on unusual and interesting case presentations and invited review papers on significant topics.
期刊最新文献
Effect of Bisoctrizole on Ultraviolet (UV) Absorption Properties of Silicone and Effect on Surface Roughness - An In Vitro Study. Effect of Densah Burs on Primary and Secondary Stability of Immediately Loaded Implants in Addition to Crestal Bone Loss and Gingival Probing Depth - An Evaluative Study. Effect of Fluoride-releasing Resin Cement on the Development of White Spot Lesions Around Orthodontic Brackets - A Retrospective Study. Effect of Reduced-Step Polishing Systems on Color Stability of Nanocomposites Submitted to Thermocycling Staining with Common Beverages - An In Vitro Study. Evaluation of Stresses Generated with Two Different Self-Ligating Orthodontic Bracket Systems - A Finite Element Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1