A Coil Rectenna Array Design to Harvest All H-Field Components for Lateral Misalignment Tolerant Wireless Powering of Bio-Medical Implant Devices

IF 3 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology Pub Date : 2024-01-22 DOI:10.1109/JERM.2024.3351751
Vivek Kumar Srivastava;Ashwani Sharma
{"title":"A Coil Rectenna Array Design to Harvest All H-Field Components for Lateral Misalignment Tolerant Wireless Powering of Bio-Medical Implant Devices","authors":"Vivek Kumar Srivastava;Ashwani Sharma","doi":"10.1109/JERM.2024.3351751","DOIUrl":null,"url":null,"abstract":"This paper presents a coil rectenna array design to address the lateral misalignment problem in near-field wireless powering of biomedical implants and wearable devices. For this purpose, the proposed design comprises three non-identical orthogonal coil antennas optimized to harvest three orthogonal H-field components efficiently. The rectified energy generated by these antenna units is utilized to supply power to the load by combining the individual rectified output voltages. Out of the two distinct combining techniques, DC and AC combining, DC combining proved advantageous in effectively harnessing the lateral field components. The design parameters of the orthogonal coil rectennas are optimized to enhance the lateral misalignment tolerance area. To realize the proposed rectenna array, a multi-layer PCB technology is employed, resulting in a compact, robust, and cost-effective solution for wireless powering of biomedical implanted and wearable devices. Experimental validation of the analytical results demonstrates that the proposed design has the potential to significantly mitigate the lateral misalignment problem in a 2D plane, achieving a uniformity percentage of \n<inline-formula><tex-math>$\\boldsymbol{38.18}$</tex-math></inline-formula>\n% for a misalignment tolerance range of \n<inline-formula><tex-math>$60\\times 60$</tex-math></inline-formula>\n mm\n<inline-formula><tex-math>$^{2}$</tex-math></inline-formula>\n.","PeriodicalId":29955,"journal":{"name":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","volume":"8 1","pages":"59-67"},"PeriodicalIF":3.0000,"publicationDate":"2024-01-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10410846/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a coil rectenna array design to address the lateral misalignment problem in near-field wireless powering of biomedical implants and wearable devices. For this purpose, the proposed design comprises three non-identical orthogonal coil antennas optimized to harvest three orthogonal H-field components efficiently. The rectified energy generated by these antenna units is utilized to supply power to the load by combining the individual rectified output voltages. Out of the two distinct combining techniques, DC and AC combining, DC combining proved advantageous in effectively harnessing the lateral field components. The design parameters of the orthogonal coil rectennas are optimized to enhance the lateral misalignment tolerance area. To realize the proposed rectenna array, a multi-layer PCB technology is employed, resulting in a compact, robust, and cost-effective solution for wireless powering of biomedical implanted and wearable devices. Experimental validation of the analytical results demonstrates that the proposed design has the potential to significantly mitigate the lateral misalignment problem in a 2D plane, achieving a uniformity percentage of $\boldsymbol{38.18}$ % for a misalignment tolerance range of $60\times 60$ mm $^{2}$ .
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
线圈整流天线阵列设计可收集所有 H 场成分,实现生物医学植入设备的侧向错位容错无线供电
本文介绍了一种线圈矩形天线阵列设计,以解决生物医学植入物和可穿戴设备近场无线供电中的横向错位问题。为此,所提出的设计由三个非相同的正交线圈天线组成,经过优化后可有效收集三个正交的 H 场分量。利用这些天线单元产生的整流能量,通过组合各个整流输出电压为负载供电。在直流和交流两种不同的组合技术中,直流组合被证明在有效利用横向场分量方面具有优势。对正交线圈整流天线的设计参数进行了优化,以提高横向偏差容限。为实现所提出的矩形天线阵列,采用了多层印刷电路板技术,从而为生物医学植入式和可穿戴设备的无线供电提供了一种紧凑、坚固且经济高效的解决方案。分析结果的实验验证表明,所提出的设计具有显著缓解二维平面横向偏差问题的潜力,在偏差公差范围为 60/times 60$ mm$^{2}$ 的情况下,均匀性百分比达到了 $/boldsymbol{38.18}$%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
9.40%
发文量
58
期刊最新文献
Front Cover Table of Contents IEEE Journal of Electromagnetics, RF, and Microwaves in Medicine and Biology About this Journal IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology Publication Information Models of Melanoma Growth for Assessment of Microwave-Based Diagnostic Tools
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1