[Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens].

Q3 Medicine Vestnik oftalmologii Pub Date : 2024-01-01 DOI:10.17116/oftalma202414001111
K S Avetisov, E A Chizhonkova, S E Avetisov, D V Andzhelova
{"title":"[Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens].","authors":"K S Avetisov, E A Chizhonkova, S E Avetisov, D V Andzhelova","doi":"10.17116/oftalma202414001111","DOIUrl":null,"url":null,"abstract":"<p><p>Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM).</p><p><strong>Purpose: </strong>This study assesses the state of the anatomical complex of the lens in MS using UBM.</p><p><strong>Material and methods: </strong>The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle.</p><p><strong>Results: </strong>There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens.</p><p><strong>Conclusion: </strong>UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.</p>","PeriodicalId":23529,"journal":{"name":"Vestnik oftalmologii","volume":"140 1","pages":"11-18"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vestnik oftalmologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/oftalma202414001111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM).

Purpose: This study assesses the state of the anatomical complex of the lens in MS using UBM.

Material and methods: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle.

Results: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens.

Conclusion: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal» values of UBM indicators of the anatomical complex of the lens.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[马凡氏综合征眼球的结构和功能特征。报告 2.晶状体解剖结构的变化]。
分析马凡氏综合症(MS)患者晶状体的变化,除了评估晶状体本身的位置外,还应该包括检查其支撑和容纳成分(睫状体带和睫状体),或者可以称之为晶状体的整个解剖复合物。由于虹膜不透明,研究眼球前段结构的光学方法只能分析晶状体在自然或医学上放大的瞳孔宽度内的状态。目的:本研究使用超声生物显微镜(UBM)评估多发性硬化症患者晶状体解剖结构的状况:本研究使用的是我们以前用于分析多发性硬化症患者眼部纤维膜变化的临床材料。在第一阶段,组成主要组(19 名多发性硬化症患者,38 只眼)和对照组(24 名近视患者,48 只眼)进行比较评估。根据患者的年龄和眼轴长度对两组进行标准化。在第二阶段,多发性硬化症患者根据生物显微镜下是否存在晶状体异位的迹象被分为不同的亚组(分别为 22 眼和 16 眼)。UBM 采用扫描频率为 50 MHz 的超声线性传感器(Aviso 设备,Quantel Medical,法国)。测定了 UBM 的各种生物计量指标:晶状体厚度、晶状体直径、晶状体轴长系数、虹膜-晶状体角、虹膜-晶状体接触距离、后房深度、睫状体带纤维长度、睫状体厚度、巩膜-睫状体角:多发性硬化症患者晶状体的解剖结构整体(晶状体本身、睫状体小体和睫状体)发生了变化,其特点是晶状体厚度增加,直径减小,睫状体小体纤维长度增加,睫状体厚度减小。同时,光学生物显微镜检测到的晶状体移位(晶状体外翻)可被视为晶状体解剖结构变化的晚期阶段:在诊断和监测多发性硬化症的变化方面,UBM 为全面观察晶状体解剖结构的所有组成部分提供了可能。将这种方法纳入眼部表现诊断算法以验证 MS 是否可取的问题仍未解决。可能存在的障碍一方面与需要特殊和昂贵的设备有关,另一方面与缺乏普遍接受的晶状体解剖综合体 UBM 指标的 "正常 "值有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Vestnik oftalmologii
Vestnik oftalmologii Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
129
期刊介绍: The journal publishes materials on the diagnosis and treatment of eye diseases, hygiene of vision, prevention of ophthalmic affections, history of Russian ophthalmology, organization of ophthalmological aid to the population, as well as the problems of special equipment. Original scientific articles and surveys on urgent problems of theory and practice of Russian and foreign ophthalmology are published. The journal contains book reviews on ophthalmology, information on the activities of ophthalmologists" scientific societies, chronicle of congresses and conferences.The journal is intended for ophthalmologists and scientific workers dealing with clinical problems of diseases of the eye and physiology of vision.
期刊最新文献
[Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens]. [Subfamily of betaherpesviruses as a cause of epithelial and stromal keratitis]. [Terson syndrome and acute myeloid leukemia (case report)]. [The association between myopia and glaucoma]. [The effect of pleoptic treatment on the stability of visual fixation in children and adolescents with amblyopia of various degrees].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1