Htay Htay, Jason Chon Jun Choo, Dorothy Hannah Huang, Mathini Jayaballa, David W Johnson, Riece Koniman, Elizabeth Ley Oei, Tan Chieh Suai, Sin Yan Wu, Marjorie Wai Yin Foo
{"title":"Rapid point-of-care test for diagnosis of peritonitis in peritoneal dialysis patients.","authors":"Htay Htay, Jason Chon Jun Choo, Dorothy Hannah Huang, Mathini Jayaballa, David W Johnson, Riece Koniman, Elizabeth Ley Oei, Tan Chieh Suai, Sin Yan Wu, Marjorie Wai Yin Foo","doi":"10.1177/08968608241234728","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Periplex<sup>®</sup> is a rapid point-of-care test based on the detection of interleukin-6 (IL-6) or matrix metalloproteinase-8 (MMP-8) to diagnose peritonitis in peritoneal dialysis (PD) patients.</p><p><strong>Methods: </strong>This single-centre study was conducted in Singapore General Hospital from 2019 to 2022. The study recruited PD patients suspected of having peritonitis. Periplex was performed at the presentation and recovery of peritonitis. Primary outcomes were sensitivity and specificity of Periplex at presentation. The positive and negative predictive values of tests were also performed.</p><p><strong>Results: </strong>A total of 120 patients were included in the study. The mean age was 60.9 ± 14.9 years, 53% were male, 79% were Chinese and 47.5% had diabetes mellitus. Periplex was positive in all patients with peritonitis (<i>n</i> = 114); sensitivity of 100%; 95% confidence interval (CI): 100-100%. Periplex was falsely positive in three patients with non-infective eosinophilic peritonitis, resulting in a low specificity of 50%; 95% CI: 41.1-59.0%. Periplex had a positive predictive value of 97.4% and a negative predictive value of 100%. During recovery from peritonitis, Periplex had high specificity (93.6%) and negative predictive value (98.7%) to indicate the resolution of infection. MMP-8 was more sensitive than IL-6 in detecting peritonitis. Periplex was positive in all patients with peritonitis regardless of the types of PD solutions used.</p><p><strong>Conclusions: </strong>Periplex had high sensitivity, and positive and negative predictive values in the diagnosis of peritonitis can be considered as a screening tool for peritonitis. Given its high specificity and negative predictive value, it may also be used to document the resolution of peritonitis.</p>","PeriodicalId":19969,"journal":{"name":"Peritoneal Dialysis International","volume":" ","pages":"413-418"},"PeriodicalIF":2.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Peritoneal Dialysis International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08968608241234728","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Periplex® is a rapid point-of-care test based on the detection of interleukin-6 (IL-6) or matrix metalloproteinase-8 (MMP-8) to diagnose peritonitis in peritoneal dialysis (PD) patients.
Methods: This single-centre study was conducted in Singapore General Hospital from 2019 to 2022. The study recruited PD patients suspected of having peritonitis. Periplex was performed at the presentation and recovery of peritonitis. Primary outcomes were sensitivity and specificity of Periplex at presentation. The positive and negative predictive values of tests were also performed.
Results: A total of 120 patients were included in the study. The mean age was 60.9 ± 14.9 years, 53% were male, 79% were Chinese and 47.5% had diabetes mellitus. Periplex was positive in all patients with peritonitis (n = 114); sensitivity of 100%; 95% confidence interval (CI): 100-100%. Periplex was falsely positive in three patients with non-infective eosinophilic peritonitis, resulting in a low specificity of 50%; 95% CI: 41.1-59.0%. Periplex had a positive predictive value of 97.4% and a negative predictive value of 100%. During recovery from peritonitis, Periplex had high specificity (93.6%) and negative predictive value (98.7%) to indicate the resolution of infection. MMP-8 was more sensitive than IL-6 in detecting peritonitis. Periplex was positive in all patients with peritonitis regardless of the types of PD solutions used.
Conclusions: Periplex had high sensitivity, and positive and negative predictive values in the diagnosis of peritonitis can be considered as a screening tool for peritonitis. Given its high specificity and negative predictive value, it may also be used to document the resolution of peritonitis.
期刊介绍:
Peritoneal Dialysis International (PDI) is an international publication dedicated to peritoneal dialysis. PDI welcomes original contributions dealing with all aspects of peritoneal dialysis from scientists working in the peritoneal dialysis field around the world.
Peritoneal Dialysis International is included in Index Medicus and indexed in Current Contents/Clinical Practice, the Science Citation Index, and Excerpta Medica (Nephrology/Urology Core Journal). It is also abstracted and indexed in Chemical Abstracts (CA), as well as being indexed in Embase as a priority journal.