Fast 5-minute shoulder MRI protocol with accelerated TSE-sequences and deep learning image reconstruction for the assessment of shoulder pain at 1.5 and 3 Tesla

IF 1.8 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING European Journal of Radiology Open Pub Date : 2024-03-08 DOI:10.1016/j.ejro.2024.100557
Judith Herrmann , You-Shan Feng , Sebastian Gassenmaier , Jan-Peter Grunz , Gregor Koerzdoerfer , Andreas Lingg , Haidara Almansour , Dominik Nickel , Ahmed E. Othman , Saif Afat
{"title":"Fast 5-minute shoulder MRI protocol with accelerated TSE-sequences and deep learning image reconstruction for the assessment of shoulder pain at 1.5 and 3 Tesla","authors":"Judith Herrmann ,&nbsp;You-Shan Feng ,&nbsp;Sebastian Gassenmaier ,&nbsp;Jan-Peter Grunz ,&nbsp;Gregor Koerzdoerfer ,&nbsp;Andreas Lingg ,&nbsp;Haidara Almansour ,&nbsp;Dominik Nickel ,&nbsp;Ahmed E. Othman ,&nbsp;Saif Afat","doi":"10.1016/j.ejro.2024.100557","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol.</p></div><div><h3>Methods</h3><p>Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSE<sub>S</sub>) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSE<sub>DL</sub>). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols.</p></div><div><h3>Results</h3><p>A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSE<sub>DL</sub> versus TSE<sub>S</sub> (p&lt;0.001). Noise and edge sharpness were evaluated to be significantly superior in TSE<sub>DL</sub> versus TSE<sub>S</sub> (noise: p&lt;0.001, edge sharpness: p&lt;0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p&gt;0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences.</p></div><div><h3>Conclusions</h3><p>A fast 5-minute TSE<sub>DL</sub> MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSE<sub>S</sub> protocol.</p></div>","PeriodicalId":38076,"journal":{"name":"European Journal of Radiology Open","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352047724000121/pdfft?md5=df816e81c966501a976ddf7cd8c5db21&pid=1-s2.0-S2352047724000121-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352047724000121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The objective of this study was to implement a 5-minute MRI protocol for the shoulder in routine clinical practice consisting of accelerated 2D turbo spin echo (TSE) sequences with deep learning (DL) reconstruction at 1.5 and 3 Tesla, and to compare the image quality and diagnostic performance to that of a standard 2D TSE protocol.

Methods

Patients undergoing shoulder MRI between October 2020 and June 2021 were prospectively enrolled. Each patient underwent two MRI examinations: first a standard, fully sampled TSE (TSES) protocol reconstructed with a standard reconstruction followed by a second fast, prospectively undersampled TSE protocol with a conventional parallel imaging undersampling pattern reconstructed with a DL reconstruction (TSEDL). Image quality and visualization of anatomic structures as well as diagnostic performance with respect to shoulder lesions were assessed using a 5-point Likert-scale (5 = best). Interchangeability analysis, Wilcoxon signed-rank test and kappa statistics were performed to compare the two protocols.

Results

A total of 30 participants was included (mean age 50±15 years; 15 men). Overall image quality was evaluated to be superior in TSEDL versus TSES (p<0.001). Noise and edge sharpness were evaluated to be significantly superior in TSEDL versus TSES (noise: p<0.001, edge sharpness: p<0.05). No difference was found concerning qualitative diagnostic confidence, assessability of anatomical structures (p>0.05), and quantitative diagnostic performance for shoulder lesions when comparing the two sequences.

Conclusions

A fast 5-minute TSEDL MRI protocol of the shoulder is feasible in routine clinical practice at 1.5 and 3 T, with interchangeable results concerning the diagnostic performance, allowing a reduction in scan time of more than 50% compared to the standard TSES protocol.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用加速 TSE 序列和深度学习图像重建的 5 分钟快速肩部 MRI 方案,在 1.5 和 3 特斯拉下评估肩部疼痛
本研究的目的是在常规临床实践中实施一种 5 分钟肩部 MRI 方案,该方案由加速二维涡轮自旋回波 (TSE) 序列和深度学习 (DL) 重建组成,频率为 1.5 和 3 特斯拉,并将图像质量和诊断性能与标准二维 TSE 方案进行比较。每位患者都接受了两次核磁共振成像检查:首先是标准、全采样 TSE(TSES)方案,采用标准重建,然后是第二个快速、前瞻性欠采样 TSE 方案,采用传统平行成像欠采样模式,采用 DL 重建(TSEDL)。图像质量、解剖结构的可视化以及肩部病变的诊断性能采用 5 点李克特量表进行评估(5 = 最佳)。通过互换性分析、Wilcoxon符号秩检验和kappa统计来比较两种方案。经评估,TSEDL 的整体图像质量优于 TSES(p<0.001)。经评估,TSEDL 的噪声和边缘锐利度明显优于 TSES(噪声:p<0.001,边缘锐利度:p<0.05)。结论 在 1.5 T 和 3 T 下,肩部 5 分钟快速 TSEDL MRI 方案在常规临床实践中是可行的,其诊断效果可互换,与标准 TSES 方案相比,扫描时间可缩短 50%以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Journal of Radiology Open
European Journal of Radiology Open Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.10
自引率
5.00%
发文量
55
审稿时长
51 days
期刊最新文献
Deep learning model for diagnosis of thyroid nodules with size less than 1 cm: A multicenter, retrospective study MRI-based radiomics machine learning model to differentiate non-clear cell renal cell carcinoma from benign renal tumors Post-deployment performance of a deep learning algorithm for normal and abnormal chest X-ray classification: A study at visa screening centers in the United Arab Emirates Study on the classification of benign and malignant breast lesions using a multi-sequence breast MRI fusion radiomics and deep learning model True cost estimation of common imaging procedures for cost-effectiveness analysis - insights from a Singapore hospital emergency department
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1