A Study of High-Frequency Noise for Microplastics Classification Using Raman Spectroscopy and Machine Learning.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-06-01 Epub Date: 2024-03-11 DOI:10.1177/00037028241233304
David Plazas, Francesco Ferranti, Qing Liu, Mehrdad Lotfi Choobbari, Heidi Ottevaere
{"title":"A Study of High-Frequency Noise for Microplastics Classification Using Raman Spectroscopy and Machine Learning.","authors":"David Plazas, Francesco Ferranti, Qing Liu, Mehrdad Lotfi Choobbari, Heidi Ottevaere","doi":"10.1177/00037028241233304","DOIUrl":null,"url":null,"abstract":"<p><p>Given the growing urge for plastic management and regulation in the world, recent studies have investigated the problem of plastic material identification for correct classification and disposal. Recent works have shown the potential of machine learning techniques for successful microplastics classification using Raman signals. Classification techniques from the machine learning area allow the identification of the type of microplastic from optical signals based on Raman spectroscopy. In this paper, we investigate the impact of high-frequency noise on the performance of related classification tasks. It is well-known that classification based on Raman is highly dependent on peak visibility, but it is also known that signal smoothing is a common step in the pre-processing of the measured signals. This raises a potential trade-off between high-frequency noise and peak preservation that depends on user-defined parameters. The results obtained in this work suggest that a linear discriminant analysis model cannot generalize properly in the presence of noisy signals, whereas an error-correcting output codes model is better suited to account for inherent noise. Moreover, principal components analysis (PCA) can become a must-do step for robust classification models, given its simplicity and natural smoothing capabilities. Our study on the high-frequency noise, the possible trade-off between pre-processing the high-frequency noise and the peak visibility, and the use of PCA as a noise reduction technique in addition to its dimensionality reduction functionality are the fundamental aspects of this work.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/00037028241233304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Given the growing urge for plastic management and regulation in the world, recent studies have investigated the problem of plastic material identification for correct classification and disposal. Recent works have shown the potential of machine learning techniques for successful microplastics classification using Raman signals. Classification techniques from the machine learning area allow the identification of the type of microplastic from optical signals based on Raman spectroscopy. In this paper, we investigate the impact of high-frequency noise on the performance of related classification tasks. It is well-known that classification based on Raman is highly dependent on peak visibility, but it is also known that signal smoothing is a common step in the pre-processing of the measured signals. This raises a potential trade-off between high-frequency noise and peak preservation that depends on user-defined parameters. The results obtained in this work suggest that a linear discriminant analysis model cannot generalize properly in the presence of noisy signals, whereas an error-correcting output codes model is better suited to account for inherent noise. Moreover, principal components analysis (PCA) can become a must-do step for robust classification models, given its simplicity and natural smoothing capabilities. Our study on the high-frequency noise, the possible trade-off between pre-processing the high-frequency noise and the peak visibility, and the use of PCA as a noise reduction technique in addition to its dimensionality reduction functionality are the fundamental aspects of this work.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用拉曼光谱和机器学习进行微塑料分类的高频噪声研究。
鉴于全球对塑料管理和监管的要求越来越高,最近的研究对塑料材料的识别问题进行了调查,以便进行正确的分类和处置。最近的研究表明,机器学习技术具有利用拉曼信号成功进行微塑料分类的潜力。机器学习领域的分类技术可以根据拉曼光谱从光学信号中识别微塑料的类型。本文研究了高频噪声对相关分类任务性能的影响。众所周知,基于拉曼光谱的分类高度依赖于峰值可见度,但同样众所周知的是,信号平滑是测量信号预处理中的一个常见步骤。这就需要在高频噪声和峰值保护之间进行权衡,而这取决于用户定义的参数。这项工作所取得的结果表明,线性判别分析模型无法在存在噪声信号的情况下进行适当的泛化,而误差校正输出编码模型则更适合考虑固有噪声。此外,鉴于主成分分析(PCA)的简单性和天然平滑能力,它可以成为稳健分类模型的必做步骤。我们对高频噪声的研究、预处理高频噪声与峰值可见度之间可能的权衡,以及将 PCA 用作除降维功能之外的降噪技术,是这项工作的基本方面。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1