The effect of macular visual field test density on central structure-function concordance in glaucoma.

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY Clinical and Experimental Optometry Pub Date : 2025-03-01 Epub Date: 2024-03-14 DOI:10.1080/08164622.2024.2319767
Daniel Rafla, Michael Kalloniatis, Jack Phu
{"title":"The effect of macular visual field test density on central structure-function concordance in glaucoma.","authors":"Daniel Rafla, Michael Kalloniatis, Jack Phu","doi":"10.1080/08164622.2024.2319767","DOIUrl":null,"url":null,"abstract":"<p><strong>Clinical relevance: </strong>Central visual field (VF) testing often requires focussed high-density test grids. The critical number of test locations for maximising structure-function concordance in the macula is not known.</p><p><strong>Purpose: </strong>The aim of this work is to determine the impact of the number of test locations in the central VF on binarized structure-function concordance in glaucoma.</p><p><strong>Methods: </strong>Humphrey Field Analyser (HFA) 10-2 test grid and Cirrus optical coherence tomography Ganglion Cell Analysis (GCA) results from one eye of 155 glaucoma patients were extracted. Following anatomical correction for retinal ganglion cell displacement, the pointwise results of the central 36 locations of the 10-2 pattern deviation map and their corresponding locations within the GCA deviation map were recorded. The number of test locations was systematically reduced from 36 (4 locations per step) and added from 1 (1 location per step) and binarized structure-function concordance (<i>p</i> < 0.05 for both) at each step was evaluated. Eleven test point subtraction and addition models were developed. Concordance rates (proportion) were plotted as a function of number of test locations, and were fitted using segmental nonlinear regression to identify the critical point of inflection at which concordance was maximised and discordance minimised.</p><p><strong>Results: </strong>Subtractive and additive approaches returned two-way estimates of the critical number, with, on average 8-14 test locations being the range at which structure-function concordance was optimised in the present cohort across all models. A randomised approach to subtracting or adding test locations returned critical numbers that were similar to systematic and empirical models, suggesting that specific test location was not as critical in optimising structure-function concordance compared to the number of test locations.</p><p><strong>Conclusion: </strong>There is a potential critical number (8-14) in macular visual field testing where binarized structure-function concordance is optimised, providing a framework for guiding the development of integrated macular test locations in VF testing for glaucoma.</p>","PeriodicalId":10214,"journal":{"name":"Clinical and Experimental Optometry","volume":" ","pages":"142-151"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Optometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08164622.2024.2319767","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Clinical relevance: Central visual field (VF) testing often requires focussed high-density test grids. The critical number of test locations for maximising structure-function concordance in the macula is not known.

Purpose: The aim of this work is to determine the impact of the number of test locations in the central VF on binarized structure-function concordance in glaucoma.

Methods: Humphrey Field Analyser (HFA) 10-2 test grid and Cirrus optical coherence tomography Ganglion Cell Analysis (GCA) results from one eye of 155 glaucoma patients were extracted. Following anatomical correction for retinal ganglion cell displacement, the pointwise results of the central 36 locations of the 10-2 pattern deviation map and their corresponding locations within the GCA deviation map were recorded. The number of test locations was systematically reduced from 36 (4 locations per step) and added from 1 (1 location per step) and binarized structure-function concordance (p < 0.05 for both) at each step was evaluated. Eleven test point subtraction and addition models were developed. Concordance rates (proportion) were plotted as a function of number of test locations, and were fitted using segmental nonlinear regression to identify the critical point of inflection at which concordance was maximised and discordance minimised.

Results: Subtractive and additive approaches returned two-way estimates of the critical number, with, on average 8-14 test locations being the range at which structure-function concordance was optimised in the present cohort across all models. A randomised approach to subtracting or adding test locations returned critical numbers that were similar to systematic and empirical models, suggesting that specific test location was not as critical in optimising structure-function concordance compared to the number of test locations.

Conclusion: There is a potential critical number (8-14) in macular visual field testing where binarized structure-function concordance is optimised, providing a framework for guiding the development of integrated macular test locations in VF testing for glaucoma.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
黄斑视野测试密度对青光眼中央结构-功能一致性的影响。
临床意义中心视野(VF)测试通常需要聚焦的高密度测试网格。目的:本研究旨在确定中心视野中测试位置的数量对青光眼二值化结构-功能一致性的影响。方法:从 155 名青光眼患者的一只眼睛中提取汉弗莱视野分析仪(HFA)10-2 测试网格和 Cirrus 光学相干断层扫描神经节细胞分析(GCA)结果。在对视网膜神经节细胞位移进行解剖校正后,记录了 10-2 模式偏差图中央 36 个位置及其在 GCA 偏差图中相应位置的点状结果。测试位置的数量从 36 个(每步 4 个位置)开始有计划地减少,从 1 个(每步 1 个位置)开始有计划地增加,并对结构-功能一致性(p 结果)进行二值化:减法和加法得出了临界数的双向估计值,平均而言,8-14 个测试点是本队列中所有模型中结构-功能一致性达到最佳的范围。采用随机方法减去或增加测试位置,得到的临界值与系统模型和经验模型相似,这表明与测试位置的数量相比,特定测试位置在优化结构-功能一致性方面并不那么关键:结论:在黄斑视野测试中存在一个潜在的临界值(8-14),在这个临界值中,二值化结构-功能一致性达到最佳,为指导青光眼黄斑视野测试中综合黄斑测试位置的开发提供了一个框架。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.10
自引率
5.30%
发文量
132
审稿时长
6-12 weeks
期刊介绍: Clinical and Experimental Optometry is a peer reviewed journal listed by ISI and abstracted by PubMed, Web of Science, Scopus, Science Citation Index and Current Contents. It publishes original research papers and reviews in clinical optometry and vision science. Debate and discussion of controversial scientific and clinical issues is encouraged and letters to the Editor and short communications expressing points of view on matters within the Journal''s areas of interest are welcome. The Journal is published six times annually.
期刊最新文献
The effect of near work on the anterior eye and associations with myopia: a narrative review. Re: 'Using ChatGPT-4 in visual field test assessment'. The use of transepithelial photorefractive keratectomy for the management of severe irregular corneal astigmatism. Manhattan Vision Screening and Follow-up Study (NYC-SIGHT): Vision and refractive error results. The effect of macular visual field test density on central structure-function concordance in glaucoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1