S. G. Gür Özcan, Nezih Zengin, Burak Bi̇li̇r, Nurcan KAÇMAZ KAT, D. Durak
{"title":"Assessment of hiatus defect size in hiatal hernia patients using computed tomography","authors":"S. G. Gür Özcan, Nezih Zengin, Burak Bi̇li̇r, Nurcan KAÇMAZ KAT, D. Durak","doi":"10.18621/eurj.1392696","DOIUrl":null,"url":null,"abstract":"Objectives: The aim of this study is to investigate the hiatus defect diameter by measuring on multi-detector computed tomography images in hiatal hernia patients.\nMethods: The multi-detector computed tomography images of 50 patients and 50 individuals in control group included in this study were investigated. The hiatus surface area (cm²), hiatus antero-posterior and transverse diameters (cm), and the thickness of both diaphragmatic crura (mm) were measured by reformatting contrast-enhanced thoraco-abdomino-pelvic computed tomography images using the region of interest method.\nResults: In this study, a significant difference was obtained among groups according to hiatus surface area, hiatus antero-posterior, and transverse diameter measurements, and both left and right diaphragmatic crural thickness measurements (P<0.001). In the patient group, the cut-off values were determined by using ROC analysis, and the values above these cut-off values enabled a hernia diagnosis with high sensitivity and specificity.\nConclusions: Measuring the hiatus surface area on multi-detector computed tomography images could serve as a supplementary criterion for diagnosing of hiatal hernia.","PeriodicalId":22571,"journal":{"name":"The European Research Journal","volume":"79 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18621/eurj.1392696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: The aim of this study is to investigate the hiatus defect diameter by measuring on multi-detector computed tomography images in hiatal hernia patients.
Methods: The multi-detector computed tomography images of 50 patients and 50 individuals in control group included in this study were investigated. The hiatus surface area (cm²), hiatus antero-posterior and transverse diameters (cm), and the thickness of both diaphragmatic crura (mm) were measured by reformatting contrast-enhanced thoraco-abdomino-pelvic computed tomography images using the region of interest method.
Results: In this study, a significant difference was obtained among groups according to hiatus surface area, hiatus antero-posterior, and transverse diameter measurements, and both left and right diaphragmatic crural thickness measurements (P<0.001). In the patient group, the cut-off values were determined by using ROC analysis, and the values above these cut-off values enabled a hernia diagnosis with high sensitivity and specificity.
Conclusions: Measuring the hiatus surface area on multi-detector computed tomography images could serve as a supplementary criterion for diagnosing of hiatal hernia.