Evaluation of the applicability of GARDskin to predict skin sensitizers in extracts from medical device materials

IF 4.7 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-03-12 DOI:10.3389/ftox.2024.1320367
Rose-Marie Jenvert, O. Larne, A. Johansson, Mattias Berglin, Emma Pedersen, Henrik Johansson
{"title":"Evaluation of the applicability of GARDskin to predict skin sensitizers in extracts from medical device materials","authors":"Rose-Marie Jenvert, O. Larne, A. Johansson, Mattias Berglin, Emma Pedersen, Henrik Johansson","doi":"10.3389/ftox.2024.1320367","DOIUrl":null,"url":null,"abstract":"Biocompatibility testing of medical devices is governed by the ISO 10993 series of standards and includes evaluation of skin sensitization potential of the final product. A majority of all medical devices are tested using in vivo methods, largely due to the lack of in vitro methods validated within the applicability domain of solid materials. The GARDskin method for assessment of chemical skin sensitizers is a validated method included in the OECD Test Guideline 442E, based on evaluation of transcriptional patterns of an endpoint-specific genomic biomarker signature in a dendritic cell-like cell, following test chemical exposure. The current study aimed to evaluate the applicability of GARDskin for the purpose of testing solid materials by incorporation of extraction procedures described in ISO 10993-12:2021, as well as to demonstrate the functionality of the proposed protocols, by testing of custom-made materials spiked with sensitizing agents. It was shown that GARDskin is compatible with both polar and non-polar extraction vehicles frequently used for the purpose of medical device biological testing. Further, exploring three different material types spiked with up to four different sensitizing agents, as well as three unspiked control materials and commercial reference products, it was shown that the method correctly classified all evaluated test materials. Taken together, the data presented suggest that GARDskin may constitute a valid alternative to in vivo experimentation for the purpose of skin sensitization assessment of medical devices.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"85 6","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/ftox.2024.1320367","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Biocompatibility testing of medical devices is governed by the ISO 10993 series of standards and includes evaluation of skin sensitization potential of the final product. A majority of all medical devices are tested using in vivo methods, largely due to the lack of in vitro methods validated within the applicability domain of solid materials. The GARDskin method for assessment of chemical skin sensitizers is a validated method included in the OECD Test Guideline 442E, based on evaluation of transcriptional patterns of an endpoint-specific genomic biomarker signature in a dendritic cell-like cell, following test chemical exposure. The current study aimed to evaluate the applicability of GARDskin for the purpose of testing solid materials by incorporation of extraction procedures described in ISO 10993-12:2021, as well as to demonstrate the functionality of the proposed protocols, by testing of custom-made materials spiked with sensitizing agents. It was shown that GARDskin is compatible with both polar and non-polar extraction vehicles frequently used for the purpose of medical device biological testing. Further, exploring three different material types spiked with up to four different sensitizing agents, as well as three unspiked control materials and commercial reference products, it was shown that the method correctly classified all evaluated test materials. Taken together, the data presented suggest that GARDskin may constitute a valid alternative to in vivo experimentation for the purpose of skin sensitization assessment of medical devices.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估 GARDskin 预测医疗器械材料提取物中皮肤致敏物质的适用性
医疗器械的生物相容性测试由 ISO 10993 系列标准规定,包括最终产品的皮肤致敏可能性评估。大部分医疗器械都采用体内方法进行测试,这主要是由于缺乏在固体材料适用范围内经过验证的体外方法。用于评估化学皮肤致敏物质的 GARDskin 方法是一种经过验证的方法,已列入《经合组织测试指南 442E》,该方法基于对测试化学品暴露后树突状细胞样细胞中端点特异性基因组生物标记特征转录模式的评估。目前的研究旨在评估 GARDskin 的适用性,以便通过纳入 ISO 10993-12:2021 中描述的提取程序来测试固体材料,并通过测试添加了致敏剂的定制材料来证明所建议方案的功能性。结果表明,GARDskin 可与医疗器械生物测试中常用的极性和非极性萃取载体兼容。此外,在对添加了多达四种不同致敏剂的三种不同材料类型以及三种未添加致敏剂的对照材料和商业参考产品进行检测后,结果表明该方法能正确分类所有被评估的测试材料。综上所述,所提供的数据表明,GARDskin 可作为体内实验的有效替代方法,用于医疗器械的皮肤过敏评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Publication Information Issue Editorial Masthead High-Performance Humidity Sensor Based on Ion–Electron Synergistic Composite Gel Fabrication and Characterization of Piezoelectric Behaviors of Directionally Well-Aligned Chitosan/Glycine Biodegradable Composite Fiber Sensors Tailoring Crystalline Morphology in Polypropylene via Ethylene Sequence Engineering for Enhanced DC Breakdown Strength
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1