Felix L. Guljé DDS, PhD, Gerry M. Raghoebar DDS, MD, PhD, Barzi Gareb DDS, MD, PhD, Arjan Vissink DDS, MD, PhD, Henny J. A. Meijer DDS, PhD
{"title":"Single crown restorations supported by 6-mm implants in the resorbed posterior mandible: A 10-year prospective case series","authors":"Felix L. Guljé DDS, PhD, Gerry M. Raghoebar DDS, MD, PhD, Barzi Gareb DDS, MD, PhD, Arjan Vissink DDS, MD, PhD, Henny J. A. Meijer DDS, PhD","doi":"10.1111/cid.13326","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To assess marginal bone level changes, implant and restoration survival, condition of the peri-implant mucosa, and the patient's satisfaction with the single restoration supported by a 6-mm long implant in the posterior mandible after 10 years in function.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Twenty-one consecutive patients missing premolars or molars in the posterior mandible, with a bone volume consisting of a width of at least 6 mm and an estimated height of 8 mm between the top of the ridge and alveolar nerve, were included. Each patient received one or more 6-mm implants. After 3 months, the implants were restored with custom-made titanium abutments and cemented zirconia-based porcelain crowns. The clinical examination and radiograph data were assessed at restoration placement and after 12, 60, and 120 months. The patients answered a questionnaire to score their satisfaction before treatment and after 12, 60, and 120 months with the restoration in function.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A total of 31 implants were placed. Implant survival was 100%. The 10-year mean marginal bone loss was 0.18 mm (SE: 0.08). The plaque, calculus, gingiva, and bleeding indices scores were low as was the mean pocket probing depth. The patients' satisfaction was high.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The 10-year follow-up data of this limited case series study reveal that 6-mm dental implants inserted in the resorbed posterior mandible provide a solid basis for single tooth restorations.</p>\n </section>\n </div>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 3","pages":"642-650"},"PeriodicalIF":3.7000,"publicationDate":"2024-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cid.13326","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13326","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To assess marginal bone level changes, implant and restoration survival, condition of the peri-implant mucosa, and the patient's satisfaction with the single restoration supported by a 6-mm long implant in the posterior mandible after 10 years in function.
Materials and Methods
Twenty-one consecutive patients missing premolars or molars in the posterior mandible, with a bone volume consisting of a width of at least 6 mm and an estimated height of 8 mm between the top of the ridge and alveolar nerve, were included. Each patient received one or more 6-mm implants. After 3 months, the implants were restored with custom-made titanium abutments and cemented zirconia-based porcelain crowns. The clinical examination and radiograph data were assessed at restoration placement and after 12, 60, and 120 months. The patients answered a questionnaire to score their satisfaction before treatment and after 12, 60, and 120 months with the restoration in function.
Results
A total of 31 implants were placed. Implant survival was 100%. The 10-year mean marginal bone loss was 0.18 mm (SE: 0.08). The plaque, calculus, gingiva, and bleeding indices scores were low as was the mean pocket probing depth. The patients' satisfaction was high.
Conclusion
The 10-year follow-up data of this limited case series study reveal that 6-mm dental implants inserted in the resorbed posterior mandible provide a solid basis for single tooth restorations.
期刊介绍:
The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal.
The range of topics covered by the journals will include but be not limited to:
New scientific developments relating to bone
Implant surfaces and their relationship to the surrounding tissues
Computer aided implant designs
Computer aided prosthetic designs
Immediate implant loading
Immediate implant placement
Materials relating to bone induction and conduction
New surgical methods relating to implant placement
New materials and methods relating to implant restorations
Methods for determining implant stability
A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.