[Determination of dimethyl oxalate and diethyl oxalate in workplace air by high performance liquid chromatography].

Z L Chen, M Wang, J F Jiang, W L Song
{"title":"[Determination of dimethyl oxalate and diethyl oxalate in workplace air by high performance liquid chromatography].","authors":"Z L Chen, M Wang, J F Jiang, W L Song","doi":"10.3760/cma.j.cn121094-20230209-00039","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To establish a high performance liquid chromatography method for the simultaneous determination of dimethyl oxalate (DMO) and diethyl oxalate (DEO) in workplace air. <b>Methods:</b> From January 2022 to January 2023, air samples were collected by silica gel tubes, desorbed by acetonitrile, separated by C18 chromatographic column, detected by photo-array detector, and retention time was used to characterize and peak area was used to quantify at 210 nm wavelength. <b>Results:</b> The linear relationships of DMO and DEO were good, <i>r</i>>0.999. The detection limits of DMO and DEO were 0.39 and 0.52 μg/ml, respectively. The quantitative limit was 1.28 μg/ml for DMO and 1.72 μg/ml for DEO. Average desorption efficiency for DMO was 82.40%-92.72%, and DEO was 94.13%-97.69%. The intra-assay precision of DMO was 1.87%-6.18%, and DEO was 2.25%-3.31%. Inter-assay precision of DMO was 3.29%-5.73%, and DEO was 1.38%-2.94%. Average sampling efficiencies were 100% for both DMO and DEO. Breakthrough capacity of DMO was 37.61 mg (200 mg solid adsorbent), DEO was >28.11 mg (200 mg solid adsorbent). Samples should be stored at 4 ℃ for at least 7 days. <b>Conclusion:</b> This method is easy to operate and has strong practicability. All indicators meet the requirements of the specification, and it is suitable for the simultaneous determination of DMO and DEO in the workplace air.</p>","PeriodicalId":23958,"journal":{"name":"中华劳动卫生职业病杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华劳动卫生职业病杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121094-20230209-00039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To establish a high performance liquid chromatography method for the simultaneous determination of dimethyl oxalate (DMO) and diethyl oxalate (DEO) in workplace air. Methods: From January 2022 to January 2023, air samples were collected by silica gel tubes, desorbed by acetonitrile, separated by C18 chromatographic column, detected by photo-array detector, and retention time was used to characterize and peak area was used to quantify at 210 nm wavelength. Results: The linear relationships of DMO and DEO were good, r>0.999. The detection limits of DMO and DEO were 0.39 and 0.52 μg/ml, respectively. The quantitative limit was 1.28 μg/ml for DMO and 1.72 μg/ml for DEO. Average desorption efficiency for DMO was 82.40%-92.72%, and DEO was 94.13%-97.69%. The intra-assay precision of DMO was 1.87%-6.18%, and DEO was 2.25%-3.31%. Inter-assay precision of DMO was 3.29%-5.73%, and DEO was 1.38%-2.94%. Average sampling efficiencies were 100% for both DMO and DEO. Breakthrough capacity of DMO was 37.61 mg (200 mg solid adsorbent), DEO was >28.11 mg (200 mg solid adsorbent). Samples should be stored at 4 ℃ for at least 7 days. Conclusion: This method is easy to operate and has strong practicability. All indicators meet the requirements of the specification, and it is suitable for the simultaneous determination of DMO and DEO in the workplace air.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[利用高效液相色谱法测定工作场所空气中的草酸二甲酯和草酸二乙酯]。
目的建立一种同时测定工作场所空气中草酸二甲酯(DMO)和草酸二乙酯(DEO)含量的高效液相色谱法。方法:自 2022 年 1 月至 2023 年 1 月,采用硅胶管采集空气样品,乙腈解吸,C18 色谱柱分离,光电阵列检测器检测,在 210 nm 波长下以保留时间定性,以峰面积定量。结果表明DMO和DEO的线性关系良好,r>0.999。DMO 和 DEO 的检出限分别为 0.39 和 0.52 μg/ml。DMO 和 DEO 的定量限分别为 1.28 μg/ml 和 1.72 μg/ml。DMO 和 DEO 的平均解吸效率分别为 82.40%-92.72% 和 94.13%-97.69% 。DMO 的测定内精密度为 1.87%-6.18%,DEO 为 2.25%-3.31%。DMO 的测定间精密度为 3.29%-5.73%,DEO 为 1.38%-2.94%。DMO 和 DEO 的平均取样效率均为 100%。DMO 的突破容量为 37.61 毫克(200 毫克固体吸附剂),DEO 的突破容量大于 28.11 毫克(200 毫克固体吸附剂)。样品应在 4 ℃ 下保存至少 7 天。结论该方法操作简便,实用性强。各项指标均符合规范要求,适用于工作场所空气中 DMO 和 DEO 的同时测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华劳动卫生职业病杂志
中华劳动卫生职业病杂志 Medicine-Medicine (all)
CiteScore
1.00
自引率
0.00%
发文量
9764
期刊介绍:
期刊最新文献
[Comparative study on the immune surveillance injury of blood cerebrospinal fluid barrier induced by exposure to lead acetate and nano-lead sulfide]. [Delphi method investigation and research on the revision of Diagnosis of Occupational Arsenic Poisoning (GBZ 83-2013)]. [Determination of 22 elements in whole blood by inductively coupled plasma mass spectrometry]. [Expression changes of miRNAs and EMT-related genes in human mesothelial cells induced by long-term exposure to asbestos]. [Influencing factors of occupational health of clinical nuclear medical staff].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1