{"title":"Radiation levels outside a patient undergoing<sup>177</sup>Lu-PSMA radioligand therapy.","authors":"Huan Li, Haikuan Liu, Weiyuan Zhang, Xin Lin, Zhiling Li, Weihai Zhuo","doi":"10.1088/1361-6498/ad3835","DOIUrl":null,"url":null,"abstract":"<p><p>Understanding the spatial distribution of radiation levels outside of a patient undergoing<sup>177</sup>Lu radioligand therapy is not only helpful for conducting correct tests for patient release, but also useful for estimation of its potential exposure to healthcare workers, caregivers, family members, and the general public. In this study, by mimicking the<sup>177</sup>Lu-labeled prostate-specific membrane antigen radioligand therapy for prostate cancers in an adult male, the spatial distribution of radiation levels outside of the phantom was simulated based on the Monte Carlo software of Particle and Heavy Ion Transport System, and verified by a series of measurements. Moreover, the normalized dose rates were further formulized on the three transverse planes representing the heights of pelvis, abdomen and chest. The results showed that the distributions of radiation levels were quite complex. Multi-directional and multi-height measurements are needed to ensure the external dose rate to meet the release criteria. In general, the radiation level was higher at the horizontal plane where the source was located, and the levels in front and behind of the body were higher than those of the left and right sides at the same height. The ratio of simulated dose rates to measured ones ranged from 0.82 to 1.19 within 1 m away from the body surface in all directions. Based on the established functions, the relative root mean square deviation between the calculated and simulated values were 0.21, 0.25 and 0.23 within a radius of 1 m on the pelvis, abdomen and chest transverse planes, respectively. It is expected that the results of this study would be helpful for guiding the test of extracorporeal radiation to determine the patient's release, and of benefit to estimate the radiation exposure to others.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad3835","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Understanding the spatial distribution of radiation levels outside of a patient undergoing177Lu radioligand therapy is not only helpful for conducting correct tests for patient release, but also useful for estimation of its potential exposure to healthcare workers, caregivers, family members, and the general public. In this study, by mimicking the177Lu-labeled prostate-specific membrane antigen radioligand therapy for prostate cancers in an adult male, the spatial distribution of radiation levels outside of the phantom was simulated based on the Monte Carlo software of Particle and Heavy Ion Transport System, and verified by a series of measurements. Moreover, the normalized dose rates were further formulized on the three transverse planes representing the heights of pelvis, abdomen and chest. The results showed that the distributions of radiation levels were quite complex. Multi-directional and multi-height measurements are needed to ensure the external dose rate to meet the release criteria. In general, the radiation level was higher at the horizontal plane where the source was located, and the levels in front and behind of the body were higher than those of the left and right sides at the same height. The ratio of simulated dose rates to measured ones ranged from 0.82 to 1.19 within 1 m away from the body surface in all directions. Based on the established functions, the relative root mean square deviation between the calculated and simulated values were 0.21, 0.25 and 0.23 within a radius of 1 m on the pelvis, abdomen and chest transverse planes, respectively. It is expected that the results of this study would be helpful for guiding the test of extracorporeal radiation to determine the patient's release, and of benefit to estimate the radiation exposure to others.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.