{"title":"Application of Hilbert-differential phase contrast to scanning transmission electron microscopy.","authors":"Haruka Iga, Toshiki Shimizu, Hiroki Minoda","doi":"10.1093/jmicro/dfae015","DOIUrl":null,"url":null,"abstract":"<p><p>We report a novel class of scanning transmission electron microscopy with Hilbert-differential phase contrast (HDP-STEM) that displays nanostructures of thin samples in a topographical manner. A semicircular π-phase plate (PP) was used as an optical device for manipulating electron waves in HDP-STEM. This is the different design from the Zernike PP used in our previous phase plate STEM (P-STEM), but both must be placed in the front focal plane of the condenser lens. HDP-STEM images of multiwalled carbon nanotubes showed higher contrast than those obtained by conventional bright-field STEM. As the PP of the HDP-STEM is nonsymmetrical, several different images were obtained by changing the detection conditions. A two-dimensional electron detector was also used to remove the scattering contrast component in the same way as with the Zernike PP and obtain an image containing only (differential) phase contrast.</p>","PeriodicalId":74193,"journal":{"name":"Microscopy (Oxford, England)","volume":" ","pages":"414-421"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy (Oxford, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jmicro/dfae015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We report a novel class of scanning transmission electron microscopy with Hilbert-differential phase contrast (HDP-STEM) that displays nanostructures of thin samples in a topographical manner. A semicircular π-phase plate (PP) was used as an optical device for manipulating electron waves in HDP-STEM. This is the different design from the Zernike PP used in our previous phase plate STEM (P-STEM), but both must be placed in the front focal plane of the condenser lens. HDP-STEM images of multiwalled carbon nanotubes showed higher contrast than those obtained by conventional bright-field STEM. As the PP of the HDP-STEM is nonsymmetrical, several different images were obtained by changing the detection conditions. A two-dimensional electron detector was also used to remove the scattering contrast component in the same way as with the Zernike PP and obtain an image containing only (differential) phase contrast.