Michael T.M. Wang , Jay J. Meyer , Ally L. Xue , Barry Power , Jennifer P. Craig
{"title":"Predictive performance of corneal and lid margin sensitivity for dry eye disease: An investigator-masked, prospective, prognostic accuracy study","authors":"Michael T.M. Wang , Jay J. Meyer , Ally L. Xue , Barry Power , Jennifer P. Craig","doi":"10.1016/j.jtos.2024.03.010","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To evaluate the prognostic ability of non-contact esthesiometry corneal and lid margin sensitivity measurements in detecting symptoms and signs of dry eye disease, as defined by the global consensus TFOS DEWS II criteria.</p></div><div><h3>Methods</h3><p>A total of 87 community residents (58 females; mean ± SD age, 53 ± 16 years) were recruited in an investigator-masked, prospective, prognostic accuracy study. Dry eye symptomology, tear film parameters, and ocular surface characteristics were evaluated in a single clinical session, and non-contact esthesiometry corneal and lid margin sensitivity measurements performed by an independent masked assessor.</p></div><div><h3>Results</h3><p>Overall, 49 (56%) participants fulfilled the TFOS DEWS II criteria for dry eye disease, while 57 (66%) exhibited clinical symptoms, and 67 (77%) had positive signs. The prognostic abilities of corneal and lid margin sensitivity measurements were significantly greater than chance for the detection dry eye signs (both p ≤ 0.03), but not for symptoms or overall disease diagnosis (all p > 0.10). The Youden-optimal prognostic cut-offs for corneal and lid margin sensitivity thresholds were both ≥0.8 mbar for the detection of clinical dry eye signs. Lid margin sensitivity demonstrated marginally higher predictive performance than corneal sensitivity (C-statistic, 0.688 versus 0.658), and was significantly correlated with tear film stability, corneal, conjunctival and lid wiper staining (all p < 0.05).</p></div><div><h3>Conclusions</h3><p>Corneal and lid margin sensitivity demonstrated moderate prognostic utility for detecting clinical dry eye signs. Future research is warranted to investigate the utility of incorporating non-contact esthesiometry in the workup for dry eye disease and neurotrophic keratopathy.</p></div>","PeriodicalId":54691,"journal":{"name":"Ocular Surface","volume":"33 ","pages":"Pages 11-15"},"PeriodicalIF":5.9000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1542012424000399/pdfft?md5=ce0dce8ce6a262c8e730cd050187ca48&pid=1-s2.0-S1542012424000399-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ocular Surface","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1542012424000399","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To evaluate the prognostic ability of non-contact esthesiometry corneal and lid margin sensitivity measurements in detecting symptoms and signs of dry eye disease, as defined by the global consensus TFOS DEWS II criteria.
Methods
A total of 87 community residents (58 females; mean ± SD age, 53 ± 16 years) were recruited in an investigator-masked, prospective, prognostic accuracy study. Dry eye symptomology, tear film parameters, and ocular surface characteristics were evaluated in a single clinical session, and non-contact esthesiometry corneal and lid margin sensitivity measurements performed by an independent masked assessor.
Results
Overall, 49 (56%) participants fulfilled the TFOS DEWS II criteria for dry eye disease, while 57 (66%) exhibited clinical symptoms, and 67 (77%) had positive signs. The prognostic abilities of corneal and lid margin sensitivity measurements were significantly greater than chance for the detection dry eye signs (both p ≤ 0.03), but not for symptoms or overall disease diagnosis (all p > 0.10). The Youden-optimal prognostic cut-offs for corneal and lid margin sensitivity thresholds were both ≥0.8 mbar for the detection of clinical dry eye signs. Lid margin sensitivity demonstrated marginally higher predictive performance than corneal sensitivity (C-statistic, 0.688 versus 0.658), and was significantly correlated with tear film stability, corneal, conjunctival and lid wiper staining (all p < 0.05).
Conclusions
Corneal and lid margin sensitivity demonstrated moderate prognostic utility for detecting clinical dry eye signs. Future research is warranted to investigate the utility of incorporating non-contact esthesiometry in the workup for dry eye disease and neurotrophic keratopathy.
期刊介绍:
The Ocular Surface, a quarterly, a peer-reviewed journal, is an authoritative resource that integrates and interprets major findings in diverse fields related to the ocular surface, including ophthalmology, optometry, genetics, molecular biology, pharmacology, immunology, infectious disease, and epidemiology. Its critical review articles cover the most current knowledge on medical and surgical management of ocular surface pathology, new understandings of ocular surface physiology, the meaning of recent discoveries on how the ocular surface responds to injury and disease, and updates on drug and device development. The journal also publishes select original research reports and articles describing cutting-edge techniques and technology in the field.
Benefits to authors
We also provide many author benefits, such as free PDFs, a liberal copyright policy, special discounts on Elsevier publications and much more. Please click here for more information on our author services.
Please see our Guide for Authors for information on article submission. If you require any further information or help, please visit our Support Center