{"title":"Surgeon Preference Regarding Wound Dressing Management in Lumbar Fusion Surgery: An AO Spine Global Cross-Sectional Study","authors":"L. Ambrosio, G. Vadalà, Javad Tavakoli, L. Scaramuzzo, G. B. Brodano, Stephen J Lewis, So Kato, Samuel K. Cho, S. T. Yoon, Ho-Joong Kim, Matthew F. Gary, Vincenzo Denaro","doi":"10.14245/ns.2347168.584","DOIUrl":null,"url":null,"abstract":"Objective To evaluate the global practice pattern of wound dressing use after lumbar fusion for degenerative conditions. Methods A survey issued by AO Spine Knowledge Forums Deformity and Degenerative was sent out to AO Spine members. The type of postoperative dressing employed, timing of initial dressing removal, and type of subsequent dressing applied were investigated. Differences in the type of surgery and regional distribution of surgeons’ preferences were analyzed. Results Right following surgery, 60.6% utilized a dry dressing, 23.2% a plastic occlusive dressing, 5.7% glue, 6% a combination of glue and polyester mesh, 2.6% a wound vacuum, and 1.2% other dressings. The initial dressing was removed on postoperative day 1 (11.6%), 2 (39.2%), 3 (20.3%), 4 (1.7%), 5 (4.3%), 6 (0.4%), 7 or later (12.5%), or depending on drain removal (9.9%). Following initial dressing removal, 75.9% applied a dry dressing, 17.7% a plastic occlusive dressing, and 1.3% glue, while 12.1% used no dressing. The use of no additional coverage after initial dressing removal was significantly associated with a later dressing change (p < 0.001). Significant differences emerged after comparing dressing management among different AO Spine regions (p < 0.001). Conclusion Most spine surgeons utilized a dry or plastic occlusive dressing initially applied after surgery. The first dressing was more frequently changed during the first 3 postoperative days and replaced with the same type of dressing. While dressing policies tended not to vary according to the type of surgery, regional differences suggest that actual practice may be based on personal experience rather than available evidence.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"100 12","pages":"204 - 211"},"PeriodicalIF":4.3000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14245/ns.2347168.584","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Objective To evaluate the global practice pattern of wound dressing use after lumbar fusion for degenerative conditions. Methods A survey issued by AO Spine Knowledge Forums Deformity and Degenerative was sent out to AO Spine members. The type of postoperative dressing employed, timing of initial dressing removal, and type of subsequent dressing applied were investigated. Differences in the type of surgery and regional distribution of surgeons’ preferences were analyzed. Results Right following surgery, 60.6% utilized a dry dressing, 23.2% a plastic occlusive dressing, 5.7% glue, 6% a combination of glue and polyester mesh, 2.6% a wound vacuum, and 1.2% other dressings. The initial dressing was removed on postoperative day 1 (11.6%), 2 (39.2%), 3 (20.3%), 4 (1.7%), 5 (4.3%), 6 (0.4%), 7 or later (12.5%), or depending on drain removal (9.9%). Following initial dressing removal, 75.9% applied a dry dressing, 17.7% a plastic occlusive dressing, and 1.3% glue, while 12.1% used no dressing. The use of no additional coverage after initial dressing removal was significantly associated with a later dressing change (p < 0.001). Significant differences emerged after comparing dressing management among different AO Spine regions (p < 0.001). Conclusion Most spine surgeons utilized a dry or plastic occlusive dressing initially applied after surgery. The first dressing was more frequently changed during the first 3 postoperative days and replaced with the same type of dressing. While dressing policies tended not to vary according to the type of surgery, regional differences suggest that actual practice may be based on personal experience rather than available evidence.
期刊介绍:
ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric.
Indexed/Abstracted:
Web of Science SCIE
Scopus
CAS
INSPEC
Portico