Ensuring uniformity of measurements in the European Metrology Cloud

IF 0.1 Q4 INSTRUMENTS & INSTRUMENTATION Ukrainian Metrological Journal Pub Date : 2024-03-28 DOI:10.24027/2306-7039.1.2024.300869
T. Bubela, V. Yatsuk, M. Mykyjchuk, O. Kochan, Y. Yatsuk
{"title":"Ensuring uniformity of measurements in the European Metrology Cloud","authors":"T. Bubela, V. Yatsuk, M. Mykyjchuk, O. Kochan, Y. Yatsuk","doi":"10.24027/2306-7039.1.2024.300869","DOIUrl":null,"url":null,"abstract":"The main requirements for the calibration of measuring channels of distributed measuring instruments at the operation site are described. When preparing for calibration, the use of portable discharge working measurement standards, which consist of a reference voltage source and a divider, is substantiated. The proposed structure of the device for calibration is based on a divider of single-nominal resistors and corresponding algorithms for processing the conversion results. The feasibility of using a divider in which the resistors are closed in a ring is substantiated. To ensure the invariance to residual parameters of switching elements when implementing several evenly spaced calibration points in the conversion range, a potential-current switching of both the input reference voltage and the output converted voltage is proposed. In addition, a method to correct the equivalent additive error component of the entire measuring channel during its calibration is proposed. The expediency of the studied measuring channels to obtain intermediate conversion results is shown. An algorithm and method of processing intermediate conversion results to obtain code values at all calibration points are proposed. To process these results, it is advisable to apply an additional software in the European Metrology Cloud. It is shown that the calibration error of the measuring channels at the operation site is determined by the error of the reference voltage source.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Metrological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24027/2306-7039.1.2024.300869","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

The main requirements for the calibration of measuring channels of distributed measuring instruments at the operation site are described. When preparing for calibration, the use of portable discharge working measurement standards, which consist of a reference voltage source and a divider, is substantiated. The proposed structure of the device for calibration is based on a divider of single-nominal resistors and corresponding algorithms for processing the conversion results. The feasibility of using a divider in which the resistors are closed in a ring is substantiated. To ensure the invariance to residual parameters of switching elements when implementing several evenly spaced calibration points in the conversion range, a potential-current switching of both the input reference voltage and the output converted voltage is proposed. In addition, a method to correct the equivalent additive error component of the entire measuring channel during its calibration is proposed. The expediency of the studied measuring channels to obtain intermediate conversion results is shown. An algorithm and method of processing intermediate conversion results to obtain code values at all calibration points are proposed. To process these results, it is advisable to apply an additional software in the European Metrology Cloud. It is shown that the calibration error of the measuring channels at the operation site is determined by the error of the reference voltage source.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
确保欧洲计量云测量的统一性
介绍了在操作现场校准分布式测量仪器测量通道的主要要求。在准备校准时,使用由基准电压源和分压器组成的便携式放电工作测量标准是有根据的。校准设备的拟议结构基于单标称电阻器分压器和处理转换结果的相应算法。使用将电阻器封闭成环形的分压器的可行性已得到证实。为了确保在转换范围内实施多个均匀分布的校准点时开关元件残余参数的不变性,提出了输入参考电压和输出转换电压的电位电流开关。此外,还提出了一种在校准过程中修正整个测量通道等效附加误差分量的方法。所研究的测量通道对获得中间转换结果的便利性得到了证明。提出了一种处理中间转换结果的算法和方法,以获得所有校准点的代码值。为了处理这些结果,建议在欧洲计量云中应用一个附加软件。结果表明,操作现场测量通道的校准误差由基准电压源的误差决定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ukrainian Metrological Journal
Ukrainian Metrological Journal INSTRUMENTS & INSTRUMENTATION-
自引率
0.00%
发文量
21
期刊最新文献
A statistical method for the assessment of metrological characteristics of reference materials Study of metrological characteristics of the state primary measurement standard of volume flow and mass consumption of liquid in preparation for participation in international comparisons The estimation of the long-term drift of the inductance measurement standards Study of reading errors when calibrating analog ohmmeters Modern approaches to studying the accuracy of determination of deformation values in geodesic monitoring of crane equipment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1