Argon pharmacokinetics: measurements in pigs and analysis in humans using a physiologically based pharmacokinetics model

IF 4.7 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-03-28 DOI:10.4103/mgr.mgr_20_23
I. Katz, R. Tissier, M. Kohlhauer, Joël Lemaire, Arthur Hamlin, Matthieu Chalopin, Géraldine Farjot, A. Milet
{"title":"Argon pharmacokinetics: measurements in pigs and analysis in humans using a physiologically based pharmacokinetics model","authors":"I. Katz, R. Tissier, M. Kohlhauer, Joël Lemaire, Arthur Hamlin, Matthieu Chalopin, Géraldine Farjot, A. Milet","doi":"10.4103/mgr.mgr_20_23","DOIUrl":null,"url":null,"abstract":"The primary objective of this study was to investigate the pharmacokinetics of inhaled argon in young pigs using mechanical ventilation. Also a physiologically based model of argon pharmacokinetics (PBPK) is validated with human data for xenon from the literature and the new data from juvenile pigs. The inherent difficulty in performing pharmacokinetics studies of argon makes the use of the PBPK model especially relevant. The model is used to investigate argon pharmacokinetics for adult and neonate applications. Juvenile pigs (n = 4) were anesthetized, submitted to endotracheal intubation, and mechanical ventilation using a conventional ventilator. Argon inhalation was achieved by switching the animal from the first mechanical ventilator (with air/oxygen) to a second one that was supplied with 75% argon and 25% oxygen from premixed gas cylinders. This administration yielded blood samples that were analyzed using a quadrupole based technique for determining argon concentration. The range of blood:gas partition coefficient corresponding to the average measured Cmax of 190–872 μM is 0.005–0.022. Based on the average curve, T1/2= 75 seconds. The PBPK is shown to be in general agreement with the experimental data in pigs. Inhaled argon administration exhibited an on-off nature such that AUC was proportional to administration time. Confidence in the PBPK model and the remarkably robust and stable on-off nature of argon pharmacokinetics, notwithstanding intersubject variability and comorbidity, suggests that inhaled argon could readily be applied to any treatment regime.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"13 1","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/mgr.mgr_20_23","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The primary objective of this study was to investigate the pharmacokinetics of inhaled argon in young pigs using mechanical ventilation. Also a physiologically based model of argon pharmacokinetics (PBPK) is validated with human data for xenon from the literature and the new data from juvenile pigs. The inherent difficulty in performing pharmacokinetics studies of argon makes the use of the PBPK model especially relevant. The model is used to investigate argon pharmacokinetics for adult and neonate applications. Juvenile pigs (n = 4) were anesthetized, submitted to endotracheal intubation, and mechanical ventilation using a conventional ventilator. Argon inhalation was achieved by switching the animal from the first mechanical ventilator (with air/oxygen) to a second one that was supplied with 75% argon and 25% oxygen from premixed gas cylinders. This administration yielded blood samples that were analyzed using a quadrupole based technique for determining argon concentration. The range of blood:gas partition coefficient corresponding to the average measured Cmax of 190–872 μM is 0.005–0.022. Based on the average curve, T1/2= 75 seconds. The PBPK is shown to be in general agreement with the experimental data in pigs. Inhaled argon administration exhibited an on-off nature such that AUC was proportional to administration time. Confidence in the PBPK model and the remarkably robust and stable on-off nature of argon pharmacokinetics, notwithstanding intersubject variability and comorbidity, suggests that inhaled argon could readily be applied to any treatment regime.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氩的药代动力学:使用基于生理的药代动力学模型对猪进行测量和对人进行分析
本研究的主要目的是研究使用机械通气的幼猪吸入氩气的药代动力学。同时,基于生理的氩气药代动力学(PBPK)模型也通过文献中的人体氙气数据和幼猪的新数据进行了验证。进行氩的药代动力学研究本身就很困难,因此使用 PBPK 模型尤为重要。该模型用于研究成人和新生儿的氩气药代动力学。对幼年猪(n = 4)进行麻醉、气管插管并使用传统呼吸机进行机械通气。氩气吸入是通过将动物从第一个机械呼吸器(空气/氧气)切换到第二个机械呼吸器来实现的,第二个机械呼吸器由预混合气瓶提供 75% 的氩气和 25% 的氧气。使用四极杆技术对血液样本进行分析,以确定氩气浓度。与 190-872 μM 的平均测量 Cmax 值相对应的血气分配系数范围为 0.005-0.022。根据平均曲线,T1/2= 75 秒。PBPK 与猪的实验数据基本一致。吸入氩气的给药表现出一种开关性质,即 AUC 与给药时间成正比。尽管受试者之间存在差异和合并症,但 PBPK 模型的可信度以及氩气药代动力学的显著稳健和稳定的开关性质表明,吸入氩气可随时应用于任何治疗方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊介绍: ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric. Indexed/​Abstracted: Web of Science SCIE Scopus CAS INSPEC Portico
期刊最新文献
Issue Publication Information Issue Editorial Masthead High-Performance Humidity Sensor Based on Ion–Electron Synergistic Composite Gel Fabrication and Characterization of Piezoelectric Behaviors of Directionally Well-Aligned Chitosan/Glycine Biodegradable Composite Fiber Sensors Tailoring Crystalline Morphology in Polypropylene via Ethylene Sequence Engineering for Enhanced DC Breakdown Strength
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1