Quality control charts for short or long runs without a training phase. Part 1. Performances in state of control and in the presence of outliers

IF 0.8 4区 工程技术 Q4 CHEMISTRY, ANALYTICAL Accreditation and Quality Assurance Pub Date : 2024-03-27 DOI:10.1007/s00769-024-01584-z
Manuel Alvarez-Prieto, Ricardo S. Páez-Montero
{"title":"Quality control charts for short or long runs without a training phase. Part 1. Performances in state of control and in the presence of outliers","authors":"Manuel Alvarez-Prieto,&nbsp;Ricardo S. Páez-Montero","doi":"10.1007/s00769-024-01584-z","DOIUrl":null,"url":null,"abstract":"<div><p>Sometimes analytical laboratories receive requests with a small number of determinations and/or a small number of samples, or outside the typical scope of analytical services. As a result, they may not have historical data on the performance of analytical processes and/or appropriate reference materials. Under these conditions it is difficult or uneconomical to use traditional or classic quality control charts. This is the so-called start-up problem of these charts. The Q charts seem appropriate charts under these conditions because they do not need any prior training or study phase. The fundamentals and the algebraic expressions of Q charts for the mean (four cases) and for the variance (two cases) are offered. This experimental study of Q charts for individual measurements was done with data from quality control for the evaluation of mass fraction of Ni and Al<sub>2</sub>O<sub>3</sub> in a laterite CRM by ICP-OES. The performance of these Q charts is discussed where the analytical process is in the state of statistical control and in the presence of outliers at the start-up. In the first situation performance of Q charts are quite satisfactory and they behave properly. When outliers are collected at the beginning, the deformation of some charts is evident or the charts become useless. Severe outliers will corrupt the parameter estimates and the subsequent plotted points, or the charts will become insensitive and useless. The practitioner should take extreme care to assure that the initial values are obtained in the state of statistical control to have adequate sensitivity to detect parameter shifts.</p></div>","PeriodicalId":454,"journal":{"name":"Accreditation and Quality Assurance","volume":"29 3","pages":"231 - 242"},"PeriodicalIF":0.8000,"publicationDate":"2024-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accreditation and Quality Assurance","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s00769-024-01584-z","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Sometimes analytical laboratories receive requests with a small number of determinations and/or a small number of samples, or outside the typical scope of analytical services. As a result, they may not have historical data on the performance of analytical processes and/or appropriate reference materials. Under these conditions it is difficult or uneconomical to use traditional or classic quality control charts. This is the so-called start-up problem of these charts. The Q charts seem appropriate charts under these conditions because they do not need any prior training or study phase. The fundamentals and the algebraic expressions of Q charts for the mean (four cases) and for the variance (two cases) are offered. This experimental study of Q charts for individual measurements was done with data from quality control for the evaluation of mass fraction of Ni and Al2O3 in a laterite CRM by ICP-OES. The performance of these Q charts is discussed where the analytical process is in the state of statistical control and in the presence of outliers at the start-up. In the first situation performance of Q charts are quite satisfactory and they behave properly. When outliers are collected at the beginning, the deformation of some charts is evident or the charts become useless. Severe outliers will corrupt the parameter estimates and the subsequent plotted points, or the charts will become insensitive and useless. The practitioner should take extreme care to assure that the initial values are obtained in the state of statistical control to have adequate sensitivity to detect parameter shifts.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无训练阶段短跑或长跑的质量控制图。第 1 部分。控制状态下和出现异常值时的性能
有时,分析实验室会收到少量测定和/或少量样品的请求,或超出典型分析服务范围的请求。因此,他们可能没有关于分析过程性能和/或适当参考材料的历史数据。在这种情况下,使用传统或经典的质量控制图很困难或不经济。这就是所谓的这些图表的启动问题。在这些条件下,Q 图表似乎是合适的图表,因为它们不需要任何事先培训或学习阶段。本文介绍了 Q 值表的基本原理以及平均值(四种情况)和方差(两种情况)的代数表达式。这项针对单个测量的 Q 值图的实验研究是通过 ICP-OES 评估红土 CRM 中 Ni 和 Al2O3 质量分数的质量控制数据完成的。我们讨论了在分析过程处于统计控制状态和启动时存在异常值的情况下这些 Q 值表的性能。在第一种情况下,Q 图的性能相当令人满意,表现正常。如果一开始就收集到异常值,一些图表就会明显变形,或者变得毫无用处。严重的异常值会破坏参数估计和随后绘制的点,或者图表变得不敏感和无用。实践者应格外小心,确保初始值是在统计控制状态下获得的,以便有足够的灵敏度来检测参数的偏移。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accreditation and Quality Assurance
Accreditation and Quality Assurance 工程技术-分析化学
CiteScore
1.80
自引率
22.20%
发文量
39
审稿时长
6-12 weeks
期刊介绍: Accreditation and Quality Assurance has established itself as the leading information and discussion forum for all aspects relevant to quality, transparency and reliability of measurement results in chemical and biological sciences. The journal serves the information needs of researchers, practitioners and decision makers dealing with quality assurance and quality management, including the development and application of metrological principles and concepts such as traceability or measurement uncertainty in the following fields: environment, nutrition, consumer protection, geology, metallurgy, pharmacy, forensics, clinical chemistry and laboratory medicine, and microbiology.
期刊最新文献
Correction: Certification of the total element mass fractions in UME EnvCRM 03 soil sample via a joint research project Association between blood lead levels and socio-demographic factors among outpatient children in Ningbo, China Proficiency tests for analysis of pesticide residues in kimchi cabbage and ginseng in South Korea from 2008 to 2020 Points to consider when establishing an equipment calibration programme in a conventional food microbiology laboratory for ISO/IEC 17025:2017 accreditation purpose Approaches for the production of reference materials with qualitative properties—The new International Standard ISO 33406
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1