Intra- and Inter-Rater Reliability of Magnetic Resonance Imaging Measurements of Supraspinatus Muscle Thickness, Acromiohumeral Distance, and Coracohumeral Distance in Patients with Shoulder Pain

B. Dede
{"title":"Intra- and Inter-Rater Reliability of Magnetic Resonance Imaging Measurements of Supraspinatus Muscle Thickness, Acromiohumeral Distance, and Coracohumeral Distance in Patients with Shoulder Pain","authors":"B. Dede","doi":"10.30733/std.2023.01702","DOIUrl":null,"url":null,"abstract":"Aim: The aim of this study was to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus muscle thickness (SMT ), \nacromiohumeral distance (AHD), and coracohumeral distance (CHD) in patients with shoulder pain. \nMaterials and Methods: This retrospective study included 80 patients who presented with complaints of shoulder pain at a single centre \nbetween January 2023 and January 2024. The supraspinatus muscle thickness, acromiohumeral distance, and coracohumeral distance \nmeasurements were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and \nstandard error of measurement were subsequently calculated. \nResults: AHD intra-rater reliability results evaluated on coronal sections were excellent (Rater 1, ICC=0.96; 95% CI, 0.94-0.97; Rater 2 ICC=0.75; \n95% CI, 0.61-0.84). AHD intra-rater reliability results evaluated on sagittal sections were excellent (Rater 1, ICC=0.94; 95% CI; 0.91-0.96; Rater 2 \nICC=0.77; 95% CI, 0.64-0.85). The results of CHD measured using coronal sections were good (Rater 1, ICC=0.85; 95% CI, 0.76-0.90; Rater 2 ICC=0.82; \n95% CI, 0.71-0.88). SMT measurement results measured using coronal sections were excellent (Rater 1, ICC=0.98; CI, 0.98-0.99; Rater 2, ICC=0.89; \n95% CI, 0.82-0.93).The inter-rater reliability values were good for AHD-Coronal (ICC= 0.75; 95% CI, 0.61-0.84) and AHD-Sagittal (ICC=0.86; 95% \nCI, 0.79-0.91), were fair for CHD evaluated on coronal sections (ICC=0.74; %95 CI, 0.58-0.83), and were excellent for SMT evaluated on \ncoronal sections (ICC=0.92; 95% CI, 0.87-0.95). \nConclusion: These results suggest that magnetic resonance imaging measurements of the supraspinatus muscle thickness and acromiohumeral \ndistance can be reliable and consistent for the clinical evaluation of patients with shoulder pain. \nKeywords: Reliability, shoulder measurement, magnetic resonance imaging","PeriodicalId":332557,"journal":{"name":"Selcuk Tip Dergisi","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Selcuk Tip Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30733/std.2023.01702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to evaluate the intra- and inter-rater reliability coefficients of the supraspinatus muscle thickness (SMT ), acromiohumeral distance (AHD), and coracohumeral distance (CHD) in patients with shoulder pain. Materials and Methods: This retrospective study included 80 patients who presented with complaints of shoulder pain at a single centre between January 2023 and January 2024. The supraspinatus muscle thickness, acromiohumeral distance, and coracohumeral distance measurements were obtained one week apart by two observers. The intraclass correlation coefficient (ICC), minimum detectable change, and standard error of measurement were subsequently calculated. Results: AHD intra-rater reliability results evaluated on coronal sections were excellent (Rater 1, ICC=0.96; 95% CI, 0.94-0.97; Rater 2 ICC=0.75; 95% CI, 0.61-0.84). AHD intra-rater reliability results evaluated on sagittal sections were excellent (Rater 1, ICC=0.94; 95% CI; 0.91-0.96; Rater 2 ICC=0.77; 95% CI, 0.64-0.85). The results of CHD measured using coronal sections were good (Rater 1, ICC=0.85; 95% CI, 0.76-0.90; Rater 2 ICC=0.82; 95% CI, 0.71-0.88). SMT measurement results measured using coronal sections were excellent (Rater 1, ICC=0.98; CI, 0.98-0.99; Rater 2, ICC=0.89; 95% CI, 0.82-0.93).The inter-rater reliability values were good for AHD-Coronal (ICC= 0.75; 95% CI, 0.61-0.84) and AHD-Sagittal (ICC=0.86; 95% CI, 0.79-0.91), were fair for CHD evaluated on coronal sections (ICC=0.74; %95 CI, 0.58-0.83), and were excellent for SMT evaluated on coronal sections (ICC=0.92; 95% CI, 0.87-0.95). Conclusion: These results suggest that magnetic resonance imaging measurements of the supraspinatus muscle thickness and acromiohumeral distance can be reliable and consistent for the clinical evaluation of patients with shoulder pain. Keywords: Reliability, shoulder measurement, magnetic resonance imaging
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肩痛患者冈上肌厚度、肱骨距离和肱骨角距离的磁共振成像测量结果的内部和相互之间的可靠性
目的:本研究旨在评估肩痛患者冈上肌厚度(SMT)、肩峰距离(AHD)和肱骨角距离(CHD)在评分者内部和评分者之间的可靠性系数。材料和方法:这项回顾性研究纳入了 2023 年 1 月至 2024 年 1 月期间在一个中心就诊的 80 名肩部疼痛患者。由两名观察者对冈上肌厚度、肩峰距离和肱冠距离进行测量,测量时间间隔为一周。随后计算了类内相关系数(ICC)、最小可检测变化和测量标准误差。结果:在冠状切片上评估的AHD评分者内部可靠性结果非常好(评分者1,ICC=0.96;95% CI,0.94-0.97;评分者2,ICC=0.75;95% CI,0.61-0.84)。在矢状切面上评估的急性心肌梗死评分者内部信度结果非常好(评分者1,ICC=0.94;95% CI;0.91-0.96;评分者2,ICC=0.77;95% CI,0.64-0.85)。使用冠状切片测量 CHD 的结果良好(评分者 1,ICC=0.85;95% CI,0.76-0.90;评分者 2,ICC=0.82;95% CI,0.71-0.88)。使用冠状切片测量的 SMT 测量结果非常好(评分者 1,ICC=0.98;CI,0.98-0.99;评分者 2,ICC=0.89;95% CI,0.82-0.93)。AHD-冠状切片(ICC=0.75;95% CI,0.61-0.84)和AHD-矢状切片(ICC=0.86;95% CI,0.79-0.91)的评分者间信度值良好,冠状切片评估CHD的评分者间信度值尚可(ICC=0.74;95% CI,0.58-0.83),冠状切片评估SMT的评分者间信度值极佳(ICC=0.92;95% CI,0.87-0.95)。结论这些结果表明,冈上肌厚度和肩峰距离的磁共振成像测量结果在肩痛患者的临床评估中具有可靠性和一致性。关键词可靠性 肩部测量 磁共振成像
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Extensive Ultrasonic Liposuction in Gynecomastia: An Alternative Approach without Surgical Gland Excision A Rare Case of Multicentric Reticulohistiocytosis in An Elderly Male Patient Monocyte/High-Density Lipoprotein Ratio: An Indicator of Oxidative Stress and Disease Severity in Lichen Planus Patients Evaluation of Attitudes and Knowledge Levels of Medical Faculty Students about Probiotics Is Being an Emergency Service Professional a Risk Factor for Violence in Healthcare
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1