Postoperative complications in cochlear implant surgery and their possible risk factors

IF 1.7 4区 医学 Q2 OTORHINOLARYNGOLOGY Brazilian Journal of Otorhinolaryngology Pub Date : 2024-03-25 DOI:10.1016/j.bjorl.2024.101428
Vanessa Ribeiro Orlando , Oswaldo Laércio Mendonça Cruz
{"title":"Postoperative complications in cochlear implant surgery and their possible risk factors","authors":"Vanessa Ribeiro Orlando ,&nbsp;Oswaldo Laércio Mendonça Cruz","doi":"10.1016/j.bjorl.2024.101428","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>This is a retrospective analysis of the major and minor complications of cochlear implants, as well as the Risk Factors (RF) involved.</p></div><div><h3>Methods</h3><p>We analyzed the medical records of patients submitted to cochlear implants at public University from 2006 to July 2019, and list here the major and minor complications found, and their risk factors.</p></div><div><h3>Results</h3><p>There were 193 ears, 100 (51.3%) from females and 93 (48.2%) from males, with a mean age of 23.63 years. In 54 of them (28%), there were alterations seen in the Temporal Bone CT scan, and 44 (22.8%) in the brain MRI. There were 158 (81.9%) insertions performed; 127 (65.8%) of them through the round window. There were 78 complications: 19 (9.8%) major and 56 (29%) minor complications. Among the major complications, there were 3 (1.6%) Surgical Site infections (SS); 5 (2.6%) hematomas/seromas; 5 (2.6%) electrode extrusion; 5 (2.6%) device faults; 1 (0.5%) wrong path. Among the minor complications, there were 6 (3.1%) Acute Otitis Media (AOM); 9 (4.7%) SS infections; 4 (2.1%) facial paresis; 17 (8.8%) vertigos; 9 (4.7%) with tinnitus. The most important RF was age. Patients younger than 2.5 years had more major complications: SS infection (<em>p</em> = 0.018) and electrode extrusion (<em>p</em> = 0.017). There was a higher rate of vertigo in adults (<em>p</em> = 0.003), and it was more often associated with comorbidities (<em>p</em> = 0.008). The insertion route, the presence of changes in CT and MRI and the CI brand used did not impact the number of complications.</p></div><div><h3>Conclusion</h3><p>Among the minor complications, those involving the vestibular system were the most common, especially in adults with comorbidities. Regarding major complications, there was an emphasis on SS infections, hematomas, seromas, electrode extrusion, especially in children under two years of age. There were implanted device faults (2.6%), with none of the brands evaluated standing out.</p></div>","PeriodicalId":49099,"journal":{"name":"Brazilian Journal of Otorhinolaryngology","volume":"90 4","pages":"Article 101428"},"PeriodicalIF":1.7000,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1808869424000430/pdfft?md5=6d46d624c937e8dae924abf3cbec6d91&pid=1-s2.0-S1808869424000430-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Otorhinolaryngology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1808869424000430","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

This is a retrospective analysis of the major and minor complications of cochlear implants, as well as the Risk Factors (RF) involved.

Methods

We analyzed the medical records of patients submitted to cochlear implants at public University from 2006 to July 2019, and list here the major and minor complications found, and their risk factors.

Results

There were 193 ears, 100 (51.3%) from females and 93 (48.2%) from males, with a mean age of 23.63 years. In 54 of them (28%), there were alterations seen in the Temporal Bone CT scan, and 44 (22.8%) in the brain MRI. There were 158 (81.9%) insertions performed; 127 (65.8%) of them through the round window. There were 78 complications: 19 (9.8%) major and 56 (29%) minor complications. Among the major complications, there were 3 (1.6%) Surgical Site infections (SS); 5 (2.6%) hematomas/seromas; 5 (2.6%) electrode extrusion; 5 (2.6%) device faults; 1 (0.5%) wrong path. Among the minor complications, there were 6 (3.1%) Acute Otitis Media (AOM); 9 (4.7%) SS infections; 4 (2.1%) facial paresis; 17 (8.8%) vertigos; 9 (4.7%) with tinnitus. The most important RF was age. Patients younger than 2.5 years had more major complications: SS infection (p = 0.018) and electrode extrusion (p = 0.017). There was a higher rate of vertigo in adults (p = 0.003), and it was more often associated with comorbidities (p = 0.008). The insertion route, the presence of changes in CT and MRI and the CI brand used did not impact the number of complications.

Conclusion

Among the minor complications, those involving the vestibular system were the most common, especially in adults with comorbidities. Regarding major complications, there was an emphasis on SS infections, hematomas, seromas, electrode extrusion, especially in children under two years of age. There were implanted device faults (2.6%), with none of the brands evaluated standing out.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人工耳蜗植入手术的术后并发症及其可能的风险因素
方法我们分析了2006年至2019年7月在公立大学接受人工耳蜗植入术的患者病历,并在此列出了发现的主要和次要并发症及其风险因素。其中 54 人(28%)在颞骨 CT 扫描中发现异常,44 人(22.8%)在脑磁共振成像中发现异常。共进行了 158 例(81.9%)植入手术,其中 127 例(65.8%)通过圆窗植入。共出现 78 例并发症:19例(9.8%)为严重并发症,56例(29%)为轻微并发症。在主要并发症中,有 3 例(1.6%)手术部位感染(SS);5 例(2.6%)血肿/血丝瘤;5 例(2.6%)电极挤出;5 例(2.6%)设备故障;1 例(0.5%)路径错误。在轻微并发症中,急性中耳炎(AOM)6 例(3.1%);SS 感染 9 例(4.7%);面瘫 4 例(2.1%);眩晕 17 例(8.8%);耳鸣 9 例(4.7%)。最重要的病因是年龄。年龄小于 2.5 岁的患者有更多的主要并发症:SS 感染(p = 0.018)和电极挤压(p = 0.017)。成人的眩晕发生率更高(p = 0.003),而且更常见于合并症(p = 0.008)。在轻微并发症中,涉及前庭系统的并发症最为常见,尤其是在有合并症的成年人中。关于主要并发症,重点是 SS 感染、血肿、血清肿、电极挤出,尤其是两岁以下儿童。植入设备出现故障(2.6%),所评估的品牌无一突出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
205
审稿时长
4-8 weeks
期刊介绍: Brazilian Journal of Otorhinolaryngology publishes original contributions in otolaryngology and the associated areas (cranio-maxillo-facial surgery and phoniatrics). The aim of this journal is the national and international divulgation of the scientific production interesting to the otolaryngology, as well as the discussion, in editorials, of subjects of scientific, academic and professional relevance. The Brazilian Journal of Otorhinolaryngology is born from the Revista Brasileira de Otorrinolaringologia, of which it is the English version, created and indexed by MEDLINE in 2005. It is the official scientific publication of the Brazilian Association of Otolaryngology and Cervicofacial Surgery. Its abbreviated title is Braz J Otorhinolaryngol., which should be used in bibliographies, footnotes and bibliographical references and strips.
期刊最新文献
Impact of smoking and alcohol drinking on the prognosis of 721 nasopharyngeal carcinoma Rehabilitation after supracricoid partial laryngectomy: cohort study Validation and reproducibility of the International Study of Asthma and Allergies in Childhood (ISAAC) Written Allergic Rhinitis Questionnaire for phone survey in children aged 6‒7 years Can anatomy-based fitting improve musical perception in adult cochlear implant users? Development and internal validation of risk stratification tool for lymph node metastasis in pT3-4 laryngeal squamous cell carcinoma patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1