Hai Zhou, Liang Fang, Ming Zhang, Gangyi Cao, Jianyang Su
{"title":"Study of the Effect of Static Eccentricity on Vibration Damping Properties of Squeeze Film Dampers Considering the Two-Phase Flow Case","authors":"Hai Zhou, Liang Fang, Ming Zhang, Gangyi Cao, Jianyang Su","doi":"10.3390/lubricants12030075","DOIUrl":null,"url":null,"abstract":"To analyze the effect of static eccentricity on the air ingestion distribution and vibration damping properties of the SFD, a numerical simulation study of SFDs considering two-phase flow was carried out based on CFD using a transient solution method and dynamic mesh technique. The results show that the angle between the static eccentricity direction and the circumferential direction of the oil supply hole increases and the air ingestion area in the oil film expands. In contrast, the oil film damping decreases, and the larger the static eccentricity distance, the greater its effect on the air ingestion area in the oil film. When the circumferential angle is small, the oil film damping increases with the increase of static eccentricity distance, and when the circumferential angle is large, the oil film damping decreases with the increase of static eccentricity distance and then increases. With the increase of static eccentricity distance, the air ingestion area at both ends of the oil film increases. At the same time, studying the effect of dynamic eccentricity shows that as the dynamic eccentricity increases, the oil film damping first decreases and then increases, and the air ingestion area increases. Comparing the 1 hole, the 2 hole, and the 3 hole oil supplies, the air ingestion area is significantly larger in the 1 hole oil supply than in the 2 hole or the 3 hole oil supplies, and the oil film damping of the 1 hole oil supply is smaller than the oil film damping of the 2 hole or the 3 hole oil supplies. It can be seen from the present study that in the actual installation of the SFD, when the circumferential angle is less than 60°, the static eccentricity can be increased appropriately. When the circumferential angle is greater than 60°, the static eccentricity can be appropriately reduced.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"23 2","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/lubricants12030075","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
To analyze the effect of static eccentricity on the air ingestion distribution and vibration damping properties of the SFD, a numerical simulation study of SFDs considering two-phase flow was carried out based on CFD using a transient solution method and dynamic mesh technique. The results show that the angle between the static eccentricity direction and the circumferential direction of the oil supply hole increases and the air ingestion area in the oil film expands. In contrast, the oil film damping decreases, and the larger the static eccentricity distance, the greater its effect on the air ingestion area in the oil film. When the circumferential angle is small, the oil film damping increases with the increase of static eccentricity distance, and when the circumferential angle is large, the oil film damping decreases with the increase of static eccentricity distance and then increases. With the increase of static eccentricity distance, the air ingestion area at both ends of the oil film increases. At the same time, studying the effect of dynamic eccentricity shows that as the dynamic eccentricity increases, the oil film damping first decreases and then increases, and the air ingestion area increases. Comparing the 1 hole, the 2 hole, and the 3 hole oil supplies, the air ingestion area is significantly larger in the 1 hole oil supply than in the 2 hole or the 3 hole oil supplies, and the oil film damping of the 1 hole oil supply is smaller than the oil film damping of the 2 hole or the 3 hole oil supplies. It can be seen from the present study that in the actual installation of the SFD, when the circumferential angle is less than 60°, the static eccentricity can be increased appropriately. When the circumferential angle is greater than 60°, the static eccentricity can be appropriately reduced.
期刊介绍:
ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric.
Indexed/Abstracted:
Web of Science SCIE
Scopus
CAS
INSPEC
Portico