{"title":"Feasibility of increasing calcium content of drinking tap water following quality regulations to improve calcium intake at population level","authors":"Natalia Matamoros, M. Puchulu, Jorge E Coleman, Eduard Maury-Sintjago, Jorge L López, Verónica Sosio, J. Belizán, Andrés Porta, G. Cormick","doi":"10.12688/gatesopenres.15184.1","DOIUrl":null,"url":null,"abstract":"Background Calcium intake is below recommendations in several parts of the world. Improving calcium intake has benefits not only for bone health but also helps to prevent pregnancy hypertension disorders. Calcium concentration of tap water is usually low The aim of the present study was to determine the maximum amount of calcium that can be added to tap water while complying with drinking water local regulations. Methods Tap water samples were collected from the Province of Buenos Aires (Argentina). Physicochemical properties and saturation index were measured. Different incremental concentrations of calcium chloride were added to the experimental aliquots. Results Baseline water had a mean calcium concentration of 22.00 ± 2.54 mg/L, water hardness of 89.9 ± 6.4 mg/L CaCO3, and a saturation index of -1.50 ± 0.11. After the addition of 0.4554 ± 0.0071 g of salt, water hard-ness reached 355.0 ± 7.1 mg/L CaCO3, a calcium concentration of 140.50 ± 2.12 mg/L, and a saturation index -0.53 ± 0.02. Conclusions This study shows that at laboratory level it is feasible to increase calcium concentration of drinking water by adding calcium chloride while complying with national standards. Calcium concentration of drinking tap water could be evaluated and minimum calcium concentration of tap water regulated so as to improve calcium intake in populations with low calcium intake.","PeriodicalId":504483,"journal":{"name":"Gates Open Research","volume":"128 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gates Open Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/gatesopenres.15184.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background Calcium intake is below recommendations in several parts of the world. Improving calcium intake has benefits not only for bone health but also helps to prevent pregnancy hypertension disorders. Calcium concentration of tap water is usually low The aim of the present study was to determine the maximum amount of calcium that can be added to tap water while complying with drinking water local regulations. Methods Tap water samples were collected from the Province of Buenos Aires (Argentina). Physicochemical properties and saturation index were measured. Different incremental concentrations of calcium chloride were added to the experimental aliquots. Results Baseline water had a mean calcium concentration of 22.00 ± 2.54 mg/L, water hardness of 89.9 ± 6.4 mg/L CaCO3, and a saturation index of -1.50 ± 0.11. After the addition of 0.4554 ± 0.0071 g of salt, water hard-ness reached 355.0 ± 7.1 mg/L CaCO3, a calcium concentration of 140.50 ± 2.12 mg/L, and a saturation index -0.53 ± 0.02. Conclusions This study shows that at laboratory level it is feasible to increase calcium concentration of drinking water by adding calcium chloride while complying with national standards. Calcium concentration of drinking tap water could be evaluated and minimum calcium concentration of tap water regulated so as to improve calcium intake in populations with low calcium intake.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据质量法规提高自来水钙含量以改善居民钙摄入量的可行性
背景 在世界一些地区,钙的摄入量低于推荐值。提高钙的摄入量不仅有利于骨骼健康,还有助于预防妊娠高血压疾病。自来水中的钙浓度通常较低。本研究的目的是确定在符合当地饮用水法规的前提下,自来水中可添加的最大钙量。方法 从布宜诺斯艾利斯省(阿根廷)采集自来水样本。测量了水的理化性质和饱和指数。在实验等分中加入不同浓度的氯化钙。结果 基准水的平均钙浓度为 22.00 ± 2.54 mg/L,水硬度为 89.9 ± 6.4 mg/L CaCO3,饱和指数为 -1.50 ± 0.11。添加 0.4554 ± 0.0071 克食盐后,水硬度达到 355.0 ± 7.1 mg/L CaCO3,钙浓度为 140.50 ± 2.12 mg/L,饱和指数为 -0.53 ± 0.02。结论 本研究表明,在实验室水平上,通过添加氯化钙来提高饮用水的钙浓度是可行的,同时也符合国家标准。可对饮用自来水的钙浓度进行评估,并对自来水的最低钙浓度进行调节,以提高低钙摄入人群的钙摄入量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
"Life mapping" exploring the lived experience of COVID-19 on access to HIV treatment and care in Malawi Contraceptive access and use before and during the COVID-19 pandemic: a mixed-methods study in South Africa and Zambia Unpacking WHO and CDC Bottle Bioassay Methods: A Comprehensive Literature Review and Protocol Analysis Revealing Key Outcome Predictors Strengthening district health management and planning: an evaluation of a multi-country initiative in Eastern and Southern Africa Identification of latent contraceptive ideational profiles among urban women in Senegal: Transitions and implications for family planning programs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1