Behavior of Fire-damaged RC Beams After Strengthening with Various Techniques

Asser M. Elsheikh, H. H. Alzamili
{"title":"Behavior of Fire-damaged RC Beams After Strengthening with Various Techniques","authors":"Asser M. Elsheikh, H. H. Alzamili","doi":"10.28991/cej-2024-010-01-012","DOIUrl":null,"url":null,"abstract":"High temperatures during a fire can significantly degrade the structural capacity of concrete. However, in many cases, it is possible to restore and strengthen fire-damaged concrete rather than completely rebuild damaged structures. The study considered two types of concrete (normal 25 MPa and high-strength 65 MPa) with two types of strengthening techniques: carbon-fiber-reinforced polymers (CFRP) sheets with different thicknesses of 1.5 and 2.5 mm and slurry-infiltrated fibrous concrete (SIFCON) jacketing with different fiber sizes of 20 and 30 mm. The numerical simulations and analyses were conducted to capture the complex behavior of fire-damaged concrete members (beams). A fire-damaged concrete beam subjected to an extreme or critical fire Exposure time (2 hours) was evaluated and modified using a finite element simulation approach. The simulation process included three stages: the first, subjecting the concrete beam to thermal loading; the second, reflecting the fire distribution map to another model of applying mechanical loading; and the third, involving the application of strengthening to the damaged model. The results showed that the strengthening using CFRP with a thickness of 2.5 improved the load-carrying capacity compared with SIFCON in both types of concrete. 200% improvement for the normal-strength concrete beam and a 136% improvement for the high-strength concrete beam, compared to the damaged beams. Doi: 10.28991/CEJ-2024-010-01-012 Full Text: PDF","PeriodicalId":10233,"journal":{"name":"Civil Engineering Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.28991/cej-2024-010-01-012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High temperatures during a fire can significantly degrade the structural capacity of concrete. However, in many cases, it is possible to restore and strengthen fire-damaged concrete rather than completely rebuild damaged structures. The study considered two types of concrete (normal 25 MPa and high-strength 65 MPa) with two types of strengthening techniques: carbon-fiber-reinforced polymers (CFRP) sheets with different thicknesses of 1.5 and 2.5 mm and slurry-infiltrated fibrous concrete (SIFCON) jacketing with different fiber sizes of 20 and 30 mm. The numerical simulations and analyses were conducted to capture the complex behavior of fire-damaged concrete members (beams). A fire-damaged concrete beam subjected to an extreme or critical fire Exposure time (2 hours) was evaluated and modified using a finite element simulation approach. The simulation process included three stages: the first, subjecting the concrete beam to thermal loading; the second, reflecting the fire distribution map to another model of applying mechanical loading; and the third, involving the application of strengthening to the damaged model. The results showed that the strengthening using CFRP with a thickness of 2.5 improved the load-carrying capacity compared with SIFCON in both types of concrete. 200% improvement for the normal-strength concrete beam and a 136% improvement for the high-strength concrete beam, compared to the damaged beams. Doi: 10.28991/CEJ-2024-010-01-012 Full Text: PDF
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用各种技术加固后受火灾损坏的 RC 梁的行为
火灾期间的高温会大大降低混凝土的结构承载能力。不过,在许多情况下,可以修复和加固被火损坏的混凝土,而不是完全重建受损结构。研究考虑了两种类型的混凝土(普通 25 兆帕和高强度 65 兆帕)和两种类型的加固技术:不同厚度(1.5 毫米和 2.5 毫米)的碳纤维增强聚合物(CFRP)片材和不同纤维尺寸(20 毫米和 30 毫米)的浆液渗透纤维混凝土(SIFCON)护套。进行数值模拟和分析的目的是捕捉受火灾破坏的混凝土构件(梁)的复杂行为。采用有限元模拟方法对遭受极端或临界火灾暴露时间(2 小时)的火灾损坏混凝土梁进行了评估和修改。模拟过程包括三个阶段:第一阶段,对混凝土梁施加热荷载;第二阶段,将火灾分布图反映到另一个施加机械荷载的模型上;第三阶段,对受损模型进行加固。结果表明,与 SIFCON 相比,使用厚度为 2.5 的 CFRP 加固可提高两种类型混凝土的承载能力。与受损梁相比,普通强度混凝土梁提高了 200%,高强度混凝土梁提高了 136%。Doi: 10.28991/CEJ-2024-010-012 全文:PDF
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Eco-friendly 3D Printing Mortar with Low Cement Content: Investigation on Printability and Mechanical Properties Response Reduction Factor for Structures with Significant Irregularities on Different Soil Stratum Assessment of Ground Penetrating Radar for Pyrite Swelling Detection in Soils Strength and Deformability of Structural Steel for Use in Construction Effect of Non-Class Fly Ash on Strength Properties of Concrete
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1