Multifunctional Thermal Biosensor Based on Silicon Thermocouple Junction and Suspended Microfluidic Channel

Tianxiang Liang, Zhen Peng, Chunyang Li, Cao Xia, Yuanlin Xia, Zhuqing Wang
{"title":"Multifunctional Thermal Biosensor Based on Silicon Thermocouple Junction and Suspended Microfluidic Channel","authors":"Tianxiang Liang, Zhen Peng, Chunyang Li, Cao Xia, Yuanlin Xia, Zhuqing Wang","doi":"10.1109/MEMS58180.2024.10439428","DOIUrl":null,"url":null,"abstract":"A multifunctional thermal biosensor based on a single thermocouple junction and suspended microfluidic multi-channels is presented in this paper. The thermal sensor was fabricated on silicon on insulator (SOI) wafers using a standard MEMS process. To minimize heat loss and increase sensitivity, suspended bridge structures were prepared on SOI substrates using a single SU8 polymer. The designed biosensor is capable of detecting multiple markers of multiple targets simultaneously, which solves the problem of low efficiency of single-channel detection and improves the detection efficiency and accuracy of biosensors. The biosensor designed for multifunctional detection exhibits an extremely high response level, with a response time of less than 100 ms and a highly linear relationship between the targets, characterized by a sensitivity of 0.5 V/W. This biosensor shows great potential for portable medical detection and Will further meet the needs of the people for modern home medical testing.","PeriodicalId":518439,"journal":{"name":"2024 IEEE 37th International Conference on Micro Electro Mechanical Systems (MEMS)","volume":"190 3","pages":"1126-1129"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2024 IEEE 37th International Conference on Micro Electro Mechanical Systems (MEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMS58180.2024.10439428","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A multifunctional thermal biosensor based on a single thermocouple junction and suspended microfluidic multi-channels is presented in this paper. The thermal sensor was fabricated on silicon on insulator (SOI) wafers using a standard MEMS process. To minimize heat loss and increase sensitivity, suspended bridge structures were prepared on SOI substrates using a single SU8 polymer. The designed biosensor is capable of detecting multiple markers of multiple targets simultaneously, which solves the problem of low efficiency of single-channel detection and improves the detection efficiency and accuracy of biosensors. The biosensor designed for multifunctional detection exhibits an extremely high response level, with a response time of less than 100 ms and a highly linear relationship between the targets, characterized by a sensitivity of 0.5 V/W. This biosensor shows great potential for portable medical detection and Will further meet the needs of the people for modern home medical testing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于硅热电偶结和悬浮微流控通道的多功能热敏生物传感器
本文介绍了一种基于单热电偶结和悬浮微流体多通道的多功能热敏生物传感器。该热传感器采用标准 MEMS 工艺在绝缘体上硅(SOI)晶片上制造而成。为了最大限度地减少热损失并提高灵敏度,在 SOI 基底上使用单一 SU8 聚合物制备了悬浮桥结构。所设计的生物传感器能够同时检测多个目标的多个标记物,解决了单通道检测效率低的问题,提高了生物传感器的检测效率和精度。为多功能检测而设计的生物传感器具有极高的响应水平,响应时间小于 100 毫秒,各目标之间呈高度线性关系,灵敏度为 0.5 V/W。这种生物传感器在便携式医疗检测方面显示出巨大潜力,将进一步满足人们对现代家庭医疗检测的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Enhanced Photodetection Capabilities of Smaller Size 2D Au/PtSi/P-Si Nanohole Array-Based MIR Schottky Detector Stretchable Fractal Electrodes Integrated on Miniature Semi-Expanded Microballoon Catheter for Directional Nerve Stimulation Mixing, Trapping, and Ejection of Single Microparticle with Size and Material Selectivity Using Acoustic Tweezers Polymethyl Methacrylate (PMMA) Pyrolysis Assisted Transfer of 2D Materials for Large-Scale Molybdenum Disulfide Nems Resonator Arrays DC Hot Switching Lifetime Study for Contact MEMS Switch by Weibull Distribution Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1