Reproducibility and sex differences in muscle oxygenation during brachial artery occlusion in healthy participants

IF 1.3 4区 医学 Q4 PHYSIOLOGY Clinical Physiology and Functional Imaging Pub Date : 2024-04-26 DOI:10.1111/cpf.12886
Tommi Jeskanen, Venla Ylinen, Rasmus I. P. Valtonen, Mikko P. Tulppo
{"title":"Reproducibility and sex differences in muscle oxygenation during brachial artery occlusion in healthy participants","authors":"Tommi Jeskanen,&nbsp;Venla Ylinen,&nbsp;Rasmus I. P. Valtonen,&nbsp;Mikko P. Tulppo","doi":"10.1111/cpf.12886","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Significance</h3>\n \n <p>Near-infrared spectroscopy (NIRS) measurement is a widely used technique to measure muscle oxygenation. A knowledge of the reproducibility of NIRS measurements is essential for the correct interpretation of data.</p>\n </section>\n \n <section>\n \n <h3> Aim</h3>\n \n <p>Our aim was to test the reproducibility and sex differences of NIRS measurements during brachial artery occlusion in healthy participants.</p>\n </section>\n \n <section>\n \n <h3> Approach</h3>\n \n <p>An NIRS device was used to measure muscle oxygenation and microvascular function during a 5 min brachial occlusion. Muscle oxygen consumption (mVO<sub>2</sub>) and tissue saturation index (TSI%) were used. The occlusion test was performed three times on separate days for males (<i>n</i> = 13, 28 ± 8 years) and females (<i>n</i> = 13, 29 ± 7 years).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>During the occlusion phase, the reproducibility of mVO<sub>2</sub> was excellent (intraclass correlation; ICC = 0.90). During the reperfusion phase, the maximal change in TSI% revealed the best reproducibility (ICC = 0.77). There were no sex differences in reproducibility. Male participants had higher muscle oxygenation during occlusion (mVO<sub>2</sub>, 0.054 ± 0.010 vs. 0.038 ± 0.012 mLO<sub>2</sub>/min/100 g, <i>p</i> = 0.001, male and female, respectively). There were no sex differences during the reperfusion phase.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The reproducibility of NIRS to measure muscle oxygenation and microvascular function during circulation occlusion and reperfusion is good to excellent. Muscle oxygen capacity measured during occlusion is higher in males compared to females, and there are no sex differences in microvascular function during the reperfusion phase.</p>\n </section>\n </div>","PeriodicalId":10504,"journal":{"name":"Clinical Physiology and Functional Imaging","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cpf.12886","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Physiology and Functional Imaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cpf.12886","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Significance

Near-infrared spectroscopy (NIRS) measurement is a widely used technique to measure muscle oxygenation. A knowledge of the reproducibility of NIRS measurements is essential for the correct interpretation of data.

Aim

Our aim was to test the reproducibility and sex differences of NIRS measurements during brachial artery occlusion in healthy participants.

Approach

An NIRS device was used to measure muscle oxygenation and microvascular function during a 5 min brachial occlusion. Muscle oxygen consumption (mVO2) and tissue saturation index (TSI%) were used. The occlusion test was performed three times on separate days for males (n = 13, 28 ± 8 years) and females (n = 13, 29 ± 7 years).

Results

During the occlusion phase, the reproducibility of mVO2 was excellent (intraclass correlation; ICC = 0.90). During the reperfusion phase, the maximal change in TSI% revealed the best reproducibility (ICC = 0.77). There were no sex differences in reproducibility. Male participants had higher muscle oxygenation during occlusion (mVO2, 0.054 ± 0.010 vs. 0.038 ± 0.012 mLO2/min/100 g, p = 0.001, male and female, respectively). There were no sex differences during the reperfusion phase.

Conclusion

The reproducibility of NIRS to measure muscle oxygenation and microvascular function during circulation occlusion and reperfusion is good to excellent. Muscle oxygen capacity measured during occlusion is higher in males compared to females, and there are no sex differences in microvascular function during the reperfusion phase.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
健康参与者肱动脉闭塞时肌肉氧合的可重复性和性别差异。
意义耳红外光谱(NIRS)测量是一种广泛用于测量肌肉氧合的技术。我们的目的是测试健康参与者在肱动脉闭塞期间进行近红外测量的可重复性和性别差异。方法使用近红外设备测量 5 分钟肱动脉闭塞期间的肌肉氧合和微血管功能。使用肌肉耗氧量(mVO2)和组织饱和度指数(TSI%)。男性(n = 13,28 ± 8 岁)和女性(n = 13,29 ± 7 岁)分别在不同的日期进行了三次闭塞测试。结果在闭塞阶段,mVO2 的重现性非常好(类内相关;ICC = 0.90)。在再灌注阶段,TSI% 的最大变化显示出最佳的再现性(ICC = 0.77)。重现性方面没有性别差异。男性参与者在闭塞期间的肌肉氧合较高(mVO2, 0.054 ± 0.010 vs. 0.038 ± 0.012 mLO2/min/100 g, p = 0.001,男性和女性分别如此)。结论 在循环闭塞和再灌注期间,近红外光谱测量肌肉氧合和微血管功能的重现性良好至极佳。闭塞期间测量的肌肉氧容量男性高于女性,再灌注阶段的微血管功能没有性别差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
5.60%
发文量
62
审稿时长
6-12 weeks
期刊介绍: Clinical Physiology and Functional Imaging publishes reports on clinical and experimental research pertinent to human physiology in health and disease. The scope of the Journal is very broad, covering all aspects of the regulatory system in the cardiovascular, renal and pulmonary systems with special emphasis on methodological aspects. The focus for the journal is, however, work that has potential clinical relevance. The Journal also features review articles on recent front-line research within these fields of interest. Covered by the major abstracting services including Current Contents and Science Citation Index, Clinical Physiology and Functional Imaging plays an important role in providing effective and productive communication among clinical physiologists world-wide.
期刊最新文献
Relationship between heart rate variability and echocardiography indices of cardiac function in healthy individuals. Plantar flexor strength and size decrease following single-leg disuse in uninjured adults: A meta-analysis. The effect of eccentric arm cycling on muscle damage and injury-related biomarkers. Issue Information COVID-19 is associated with cardiac structural and functional remodelling in healthy middle-aged and older individuals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1