{"title":"Candidate reference measurement procedure for serum 17-hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry","authors":"Ji Zhang,&nbsp;Yang Jiang,&nbsp;Ting Liu,&nbsp;Xiongwei Liu,&nbsp;Hui Huang,&nbsp;Yanxiang Cheng,&nbsp;Jieyan Li,&nbsp;Bangning Cheng,&nbsp;Chungen Qian,&nbsp;Xufu Xiang,&nbsp;Jun-Fa Xu","doi":"10.1002/ila2.39","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Accurate quantification of 17-hydroxyprogesterone (17-OHP) in serum is vital for clinical and research applications. However, inter-laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure (RMP). Therefore, in this study, we developed a highly accurate, cost-effective, and user-friendly candidate RMP (cRMP) for analyzing 17-OHP in serum.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>We quantified 17-OHP in serum using a one-step liquid–liquid extraction method with the addition of 17-OHP-<sup>13</sup>C<sub>3</sub>, followed by liquid chromatography–tandem mass spectrometry. The ability of these methods to suppress interference was evaluated by chromatographic analysis. We assessed accuracy, specificity, the lower limit of quantitation, linearity, and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute. The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The developed cRMP required only 8 min for accurate quantification of serum 17-OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents. The method exhibited favorable measurement performance, with a quantitation limit of 0.086 ng/mL, linear range of 0.1–400 ng/mL, a total imprecision of ≤2.90%, spike recovery of 100.1%–100.6%, and relative deviations from assigned target values (RfB Institution) of −2.91% to 1.10%. The cRMP demonstrated good consistency with the conventional assay (chemiluminescence method), with a correlation coefficient <i>R</i> of 0.96977.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>A cRMP with high accuracy, cost-effectiveness, and convenient operation was developed for quantifying 17-OHP in serum. Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories. This method can enhance the accuracy and reliability of 17-OHP measurements across various laboratories.</p>\n </section>\n </div>","PeriodicalId":100656,"journal":{"name":"iLABMED","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ila2.39","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"iLABMED","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ila2.39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Accurate quantification of 17-hydroxyprogesterone (17-OHP) in serum is vital for clinical and research applications. However, inter-laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure (RMP). Therefore, in this study, we developed a highly accurate, cost-effective, and user-friendly candidate RMP (cRMP) for analyzing 17-OHP in serum.

Methods

We quantified 17-OHP in serum using a one-step liquid–liquid extraction method with the addition of 17-OHP-13C3, followed by liquid chromatography–tandem mass spectrometry. The ability of these methods to suppress interference was evaluated by chromatographic analysis. We assessed accuracy, specificity, the lower limit of quantitation, linearity, and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute. The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.

Results

The developed cRMP required only 8 min for accurate quantification of serum 17-OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents. The method exhibited favorable measurement performance, with a quantitation limit of 0.086 ng/mL, linear range of 0.1–400 ng/mL, a total imprecision of ≤2.90%, spike recovery of 100.1%–100.6%, and relative deviations from assigned target values (RfB Institution) of −2.91% to 1.10%. The cRMP demonstrated good consistency with the conventional assay (chemiluminescence method), with a correlation coefficient R of 0.96977.

Conclusion

A cRMP with high accuracy, cost-effectiveness, and convenient operation was developed for quantifying 17-OHP in serum. Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories. This method can enhance the accuracy and reliability of 17-OHP measurements across various laboratories.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过同位素稀释液相色谱-串联质谱法定量血清 17-羟孕酮的候选参考测量程序
血清中 17- 羟孕酮(17-OHP)的准确定量对于临床和研究应用至关重要。然而,由于缺乏标准化的参考测量程序(RMP),实验室间的检测结果存在差异。因此,在本研究中,我们开发了一种高度准确、经济高效、操作简便的候选参考测量程序(cRMP),用于分析血清中的 17-OHP。我们采用添加 17-OHP-13C3 的一步式液液萃取法,然后用液相色谱-串联质谱法定量检测血清中的 17-OHP。通过色谱分析评估了这些方法抑制干扰的能力。我们按照临床和实验室标准协会规定的标准评估了准确性、特异性、定量下限、线性和基质效应。通过对 120 份临床样本的实验,评估了所开发的 cRMP 与化学发光法之间的一致性。所开发的 cRMP 只需 8 分钟就能准确定量血清中的 17-OHP,而不会受到基质效应的影响,也不会受到作为潜在干扰物加入的 19 种代谢物的干扰。该方法具有良好的测量性能,定量限为 0.086 ng/mL,线性范围为 0.1-400 ng/mL,总不精密度≤2.90%,加标回收率为 100.1%-100.6%,与指定目标值的相对偏差(RfB 机构)为-2.91%-1.10%。cRMP 与传统检测方法(化学发光法)具有良好的一致性,相关系数 R 为 0.96977。该方法简便易行、性能稳定,是实验室分析工具库中的宝贵补充。该方法可提高不同实验室测定 17-OHP 的准确性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Issue Information Regulatory factors of ILC2 are therapeutic targets for lung inflammation Etiology, clinical features, and epidemiological analysis of diarrhea patients visiting a gastrointestinal clinic in a comprehensive hospital in Beijing, China, in 2023 A retrospective analysis of the relationship between dermatomyositis-associated interstitial lung disease and disease duration, age, arterial blood gas pH, and serum Cl− levels Ginkgo biloba active compounds can modulate the development of acute mountain sickness and ischemic stroke as discovered by network pharmacology and molecular docking
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1