{"title":"Improved sieving coefficient in perfusion cell culture with reduced effective filtration length of hollow fibers","authors":"Jimmy Vu, J. Alex Gadberry, Jon Coffman, Ken Lee","doi":"10.1002/btpr.3472","DOIUrl":null,"url":null,"abstract":"<p>The hollow fiber filter is the primary cell-retention device used in high-density perfusion cell culture and often used in an alternating tangential flow (ATF) configuration. The limited commercially available diaphragm pumps for ATF prevent utilization of vertical space when scaling beyond 500 L. Stacking hollow fiber filters coupled with viscous cell culture imposes vacuum pressure exceeding facility capabilities. Additionally, the longer filter assembly increases the hold-up volume and exceeds the diaphragm pump's fluid exchange capacity. The conventional tangential flow filtration (TFF) configuration circumvents this issue by exchanging culture from the bioreactor and cell-retention device in a unidirectional recirculation loop; however, the increased filter length when scaled up exacerbates the TFF's inherent issue with product retention from Starling flow. Stacking commercially available 20 cm TFF filters to make up the similar single-module length TFF used for the platform 3 and 50 L perfusion process at 41.5 and 65 cm, respectively, attempts to reduce fouling caused by Starling flow. The permeate of a single-module filter is partitioned into short independent segments through serially stacked filters, each harvested separately. By partitioning the permeate, the sieving coefficient increased for both 3 and 50 L scales. Reduction of Starling flow was confirmed with lower total hydraulic membrane resistance throughout the culture. This work demonstrates a method for increasing sieving coefficient and filter capacity by stacking TFF filters with independent permeate streams.</p>","PeriodicalId":8856,"journal":{"name":"Biotechnology Progress","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/btpr.3472","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotechnology Progress","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/btpr.3472","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The hollow fiber filter is the primary cell-retention device used in high-density perfusion cell culture and often used in an alternating tangential flow (ATF) configuration. The limited commercially available diaphragm pumps for ATF prevent utilization of vertical space when scaling beyond 500 L. Stacking hollow fiber filters coupled with viscous cell culture imposes vacuum pressure exceeding facility capabilities. Additionally, the longer filter assembly increases the hold-up volume and exceeds the diaphragm pump's fluid exchange capacity. The conventional tangential flow filtration (TFF) configuration circumvents this issue by exchanging culture from the bioreactor and cell-retention device in a unidirectional recirculation loop; however, the increased filter length when scaled up exacerbates the TFF's inherent issue with product retention from Starling flow. Stacking commercially available 20 cm TFF filters to make up the similar single-module length TFF used for the platform 3 and 50 L perfusion process at 41.5 and 65 cm, respectively, attempts to reduce fouling caused by Starling flow. The permeate of a single-module filter is partitioned into short independent segments through serially stacked filters, each harvested separately. By partitioning the permeate, the sieving coefficient increased for both 3 and 50 L scales. Reduction of Starling flow was confirmed with lower total hydraulic membrane resistance throughout the culture. This work demonstrates a method for increasing sieving coefficient and filter capacity by stacking TFF filters with independent permeate streams.
期刊介绍:
Biotechnology Progress , an official, bimonthly publication of the American Institute of Chemical Engineers and its technological community, the Society for Biological Engineering, features peer-reviewed research articles, reviews, and descriptions of emerging techniques for the development and design of new processes, products, and devices for the biotechnology, biopharmaceutical and bioprocess industries.
Widespread interest includes application of biological and engineering principles in fields such as applied cellular physiology and metabolic engineering, biocatalysis and bioreactor design, bioseparations and downstream processing, cell culture and tissue engineering, biosensors and process control, bioinformatics and systems biology, biomaterials and artificial organs, stem cell biology and genetics, and plant biology and food science. Manuscripts concerning the design of related processes, products, or devices are also encouraged. Four types of manuscripts are printed in the Journal: Research Papers, Topical or Review Papers, Letters to the Editor, and R & D Notes.