Combined ns pulsed-RF excitation and impedance matching considerations for the production of moderate E/n atmospheric pressure discharges for gas conversion

Dante Filice, Sylvain Coulombe
{"title":"Combined ns pulsed-RF excitation and impedance matching considerations for the production of moderate E/n atmospheric pressure discharges for gas conversion","authors":"Dante Filice, Sylvain Coulombe","doi":"10.1088/1361-6595/ad42d0","DOIUrl":null,"url":null,"abstract":"\n Sub-breakdown radiofrequency (RF) discharges enabled by a nanosecond (ns) pulse ignition source are studied at atmospheric pressure in a range of gas mixtures from completely inert (in Ar) to completely reactive (in CO2). An electrical characterisation of the continuous wave (CW) RF discharge (13.56MHz) is performed to determine plasma impedance and plasma power dissipation. Two different measurement methods to electrically characterize the system are described and compared. One method uses in-situ measurements of discharge parameters (voltage, current and the phase angle), and the other method performs ex-situ measurements of the load circuit using a vector network analyser. It was found that RF plasma power deposition depended on the applied RF power as well as the gas mixture composition. Using the in-situ voltage, current and phase angle measurements, plasma power deposition was calculated to be as much as 85% and 76% of the applied RF power for the pure Ar and pure CO2 cases, respectively. A preliminary qualitative assessment of the plasma composition was performed by optical emission spectroscopy, and CO2 conversion by mass spectrometry. CO2 to CO conversions of 11.2% and 5.5% in a 20:80 (CO2:Ar) mixture and in 100% CO2, respectively, were observed. This study demonstrates a RF plasma source for gas conversion applications at atmospheric pressure in a completely reactive gas.","PeriodicalId":508056,"journal":{"name":"Plasma Sources Science and Technology","volume":"10 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Sources Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1361-6595/ad42d0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sub-breakdown radiofrequency (RF) discharges enabled by a nanosecond (ns) pulse ignition source are studied at atmospheric pressure in a range of gas mixtures from completely inert (in Ar) to completely reactive (in CO2). An electrical characterisation of the continuous wave (CW) RF discharge (13.56MHz) is performed to determine plasma impedance and plasma power dissipation. Two different measurement methods to electrically characterize the system are described and compared. One method uses in-situ measurements of discharge parameters (voltage, current and the phase angle), and the other method performs ex-situ measurements of the load circuit using a vector network analyser. It was found that RF plasma power deposition depended on the applied RF power as well as the gas mixture composition. Using the in-situ voltage, current and phase angle measurements, plasma power deposition was calculated to be as much as 85% and 76% of the applied RF power for the pure Ar and pure CO2 cases, respectively. A preliminary qualitative assessment of the plasma composition was performed by optical emission spectroscopy, and CO2 conversion by mass spectrometry. CO2 to CO conversions of 11.2% and 5.5% in a 20:80 (CO2:Ar) mixture and in 100% CO2, respectively, were observed. This study demonstrates a RF plasma source for gas conversion applications at atmospheric pressure in a completely reactive gas.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
生产用于气体转换的中等 E/n 常压放电的 ns 脉冲射频激励和阻抗匹配组合考虑因素
研究了在大气压力下,从完全惰性(在氩气中)到完全反应性(在二氧化碳中)的一系列气体混合物中,由纳秒(ns)脉冲点火源产生的次击穿射频(RF)放电。对连续波(CW)射频放电(13.56MHz)进行了电学表征,以确定等离子体阻抗和等离子体功率耗散。文中介绍了两种不同的测量方法,并对其进行了比较。一种方法是对放电参数(电压、电流和相位角)进行现场测量,另一种方法是使用矢量网络分析仪对负载电路进行现场测量。结果发现,射频等离子体功率沉积取决于应用的射频功率和气体混合物成分。通过原位电压、电流和相位角测量,计算出纯 Ar 和纯 CO2 的等离子功率沉积分别为应用射频功率的 85% 和 76%。通过光学发射光谱对等离子体的成分进行了初步定性评估,并通过质谱法对二氧化碳的转化率进行了评估。在 20:80(CO2:Ar)混合物和 100% CO2 中,CO2 对 CO 的转化率分别为 11.2% 和 5.5%。这项研究展示了一种射频等离子体源,可用于在常压下完全反应气体中的气体转化应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Generation of high-density plasma via transparent electrode in capacitively coupled plasma Variations of plasma potential in RF discharges with DC-grounded electrode In situ measurement of electron emission yield at Si and SiO2 surfaces exposed to Ar/CF4 plasmas Study of atoms and multiply charged ions features in the nanosecond laser produced Mo plasma in vacuum using optical emission spectroscopy and time-of-flight electrostatic energy analyzer Ozone production by an He+O2 radio-frequency atmospheric pressure plasma jet driven by tailored voltage waveforms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1