Effects of transpalatal arch wire dimension and temporary skeletal anchorage device position on maxillary molar intrusion

Xiaoting Wang, Yi-chen Zhao, Mingyue Fan, Ting Zhou, Bing Fang, Niansong Ye
{"title":"Effects of transpalatal arch wire dimension and temporary skeletal anchorage device position on maxillary molar intrusion","authors":"Xiaoting Wang, Yi-chen Zhao, Mingyue Fan, Ting Zhou, Bing Fang, Niansong Ye","doi":"10.2319/102423-721.1","DOIUrl":null,"url":null,"abstract":"\n \n \n To investigate the effects of transpalatal (TPA) wire dimension and temporary skeletal anchorage device (TSAD) position on maxillary molar intrusion.\n \n \n \n The maxillary molar intrusion measurement system included a maxillary acrylic model, TPA, TSADs, and a three-dimensional Force/Moment (F/M) sensor. The intrusion patterns were categorized into six groups: buccal-mesial, buccal-distal, buccal-mesiodistal, palatal-mesial, palatal-distal, and palatal-mesiodistal. TPA wire dimensions were designed to be 0.7 mm, 0.9 mm, and 1.2 mm. The force and moment loads of the maxillary first molar were measured by the F/M sensor.\n \n \n \n Single buccal or palatal TSADs induced torquing movement, and single mesial or distal TSADs tended to promote tipping movement. Mesiodistal TSADs would have eliminated tipping, but accentuated torquing movement. The TPA significantly reduced the force and moment experienced by the maxillary first molar along three-dimensional axes. The thicker the TPA wire, the smaller the force and moment to which the maxillary first molar was subjected.\n \n \n \n Precise placement of TSADs might have a substantial influence on tooth movement and should be determined in accordance with specific clinical requirements. Increasing the TPA wire dimension could diminish the tipping, torquing, and rotation during TSAD-assisted maxillary molar intrusion, but these tendencies could not be completely eliminated.\n","PeriodicalId":94224,"journal":{"name":"The Angle orthodontist","volume":"53 14","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Angle orthodontist","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.2319/102423-721.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To investigate the effects of transpalatal (TPA) wire dimension and temporary skeletal anchorage device (TSAD) position on maxillary molar intrusion. The maxillary molar intrusion measurement system included a maxillary acrylic model, TPA, TSADs, and a three-dimensional Force/Moment (F/M) sensor. The intrusion patterns were categorized into six groups: buccal-mesial, buccal-distal, buccal-mesiodistal, palatal-mesial, palatal-distal, and palatal-mesiodistal. TPA wire dimensions were designed to be 0.7 mm, 0.9 mm, and 1.2 mm. The force and moment loads of the maxillary first molar were measured by the F/M sensor. Single buccal or palatal TSADs induced torquing movement, and single mesial or distal TSADs tended to promote tipping movement. Mesiodistal TSADs would have eliminated tipping, but accentuated torquing movement. The TPA significantly reduced the force and moment experienced by the maxillary first molar along three-dimensional axes. The thicker the TPA wire, the smaller the force and moment to which the maxillary first molar was subjected. Precise placement of TSADs might have a substantial influence on tooth movement and should be determined in accordance with specific clinical requirements. Increasing the TPA wire dimension could diminish the tipping, torquing, and rotation during TSAD-assisted maxillary molar intrusion, but these tendencies could not be completely eliminated.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
腭侧弓丝尺寸和临时骨骼锚定装置位置对上颌磨牙内陷的影响
研究经腭裂(TPA)钢丝尺寸和临时骨骼锚定装置(TSAD)位置对上颌臼齿内陷的影响。 上颌臼齿内侵测量系统包括上颌丙烯酸模型、TPA、TSAD 和三维力/力矩(F/M)传感器。入侵模式分为六组:颊-颊面、颊-远侧、颊-密-密侧、腭-颊面、腭-远侧和腭-密-密侧。TPA 线的尺寸设计为 0.7 毫米、0.9 毫米和 1.2 毫米。上颌第一磨牙的力和力矩载荷由 F/M 传感器测量。 单个颊侧或腭侧 TSAD 引起扭转运动,而单个中侧或远侧 TSAD 则倾向于促进倾翻运动。中侧 TSAD 可消除倾倒,但会加剧扭转运动。TPA 能明显减少上颌第一磨牙沿三维轴线所受的力和力矩。TPA 金丝越粗,上颌第一磨牙受到的力和力矩就越小。 TSAD的精确放置可能会对牙齿移动产生重大影响,因此应根据具体的临床要求来确定。增加TPA钢丝的尺寸可以减少TSAD辅助上颌臼齿固位过程中的倾倒、扭转和旋转,但这些趋势并不能完全消除。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Eruptive path of maxillary canines in patients with lateral incisor agenesis: a longitudinal follow-up. Which orthodontic articles are accessed online the most? Exploring article usage metrics along with citations and altmetrics. Three-dimensional assessment of the nasopharyngeal airway in Down syndrome during the mixed dentition period: a case-control study. Efficacy of planned moderate to severe torque changes in mandibular central incisors with an initial series of Invisalign aligners: a retrospective cohort study. An in vitro study of a combined patient-specific device for safe and accurate insertion of infrazygomatic crest miniscrews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1