Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database

Yazan Almomani, Roaa Alawadi, Ahmad N. Tarawneh, Abdullah Alghossoon, Ahmad Aldiabat
{"title":"Punching Shear of FRP-RC Slab–Column Connections: A Comprehensive Database","authors":"Yazan Almomani, Roaa Alawadi, Ahmad N. Tarawneh, Abdullah Alghossoon, Ahmad Aldiabat","doi":"10.3390/jcs8040145","DOIUrl":null,"url":null,"abstract":"Several design standards have been developed in the last two decades to estimate the punching capacity of two-way reinforced concrete (RC) slabs reinforced with fiber-reinforced polymer (FRP) reinforcement. FRP-RC design standards include the recently published ACI 440.11-22, CSA/S806-12, and JSCE-2007. These models are either based on empirical data or semi-empirical methods and calibrated using different databases. Additionally, these standards do not have provisions for connections with shear reinforcement. Therefore, a reliable worldwide database for developing and assessing the applicability of such provisions with test results is vital. This study presents a worldwide and up-to-date database for punching shear of FRP-RC slabs. The database includes 197 tested connections, comprising interior and edge connections, with and without shear reinforcement, and a wide range of materials and cross-sectional properties. The database was used to evaluate the accuracy of the mentioned standards in predicting the punching shear capacity. For connections without shear reinforcement, it was determined that the three design standards yielded similar performance with different conservatism levels. ACI 440.11-22 yielded the most conservative results, with average Vexp/Vpred ratios of 2.04 compared to 1.28 and 1.3 for other models. For connection with shear reinforcement, specimens with Evf> 100 GPa resulted in Vexp/Vpred ratios less than 1.0 for ACI and CSA standards.","PeriodicalId":502935,"journal":{"name":"Journal of Composites Science","volume":"6 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Composites Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jcs8040145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Several design standards have been developed in the last two decades to estimate the punching capacity of two-way reinforced concrete (RC) slabs reinforced with fiber-reinforced polymer (FRP) reinforcement. FRP-RC design standards include the recently published ACI 440.11-22, CSA/S806-12, and JSCE-2007. These models are either based on empirical data or semi-empirical methods and calibrated using different databases. Additionally, these standards do not have provisions for connections with shear reinforcement. Therefore, a reliable worldwide database for developing and assessing the applicability of such provisions with test results is vital. This study presents a worldwide and up-to-date database for punching shear of FRP-RC slabs. The database includes 197 tested connections, comprising interior and edge connections, with and without shear reinforcement, and a wide range of materials and cross-sectional properties. The database was used to evaluate the accuracy of the mentioned standards in predicting the punching shear capacity. For connections without shear reinforcement, it was determined that the three design standards yielded similar performance with different conservatism levels. ACI 440.11-22 yielded the most conservative results, with average Vexp/Vpred ratios of 2.04 compared to 1.28 and 1.3 for other models. For connection with shear reinforcement, specimens with Evf> 100 GPa resulted in Vexp/Vpred ratios less than 1.0 for ACI and CSA standards.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
FRP-RC 板柱连接的冲剪力:综合数据库
在过去的二十年中,已经制定了多个设计标准来估算用纤维增强聚合物(FRP)加固的双向钢筋混凝土(RC)板的抗冲击能力。FRP-RC 设计标准包括最近出版的 ACI 440.11-22、CSA/S806-12 和 JSCE-2007。这些模型或基于经验数据,或基于半经验方法,并使用不同的数据库进行校准。此外,这些标准中没有关于剪力加固连接的规定。因此,建立一个可靠的全球数据库,以便根据测试结果制定和评估这些规定的适用性至关重要。本研究为 FRP-RC 板的冲剪提供了一个全球性的最新数据库。该数据库包含 197 个经过测试的连接,包括内部连接和边缘连接、有剪力加固和无剪力加固,以及各种材料和截面特性。该数据库用于评估上述标准在预测冲剪能力方面的准确性。对于无剪力加固的连接,三种设计标准的性能相似,但保守程度不同。ACI 440.11-22 的结果最为保守,平均 Vexp/Vpred 比率为 2.04,而其他模型的平均 Vexp/Vpred 比率分别为 1.28 和 1.3。对于带剪力加固的连接,Evf> 100 GPa 的试样导致 ACI 和 CSA 标准的 Vexp/Vpred 比值小于 1.0。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of the Incorporation of Olive Tree Pruning Sawdust in the Production of Lightweight Mortars Properties of Composites Based on Polylactide Filled with Cork Filler Influence of Silica Nanoparticles on the Physical Properties of Random Polypropylene Analytical and Experimental Behaviour of GFRP-Reinforced Concrete Columns under Fire Loading Mechanical Characterization of Hybrid Steel Wire Mesh/Basalt/Epoxy Fiber-Reinforced Polymer Composite Laminates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1