Therapeutic Drug Monitoring of 6 New-Generation Antiseizure Medications Using a Mass Spectrometry Method: Analysis of 2-Year Experience in a Large Cohort of Korean Epilepsy Patients.
Sang-Mi Kim, Won Young Heo, Hyeonju Oh, Eun Yeon Joo, Young-Min Shon, S. Hong, Soo-Youn Lee, Dae-Won Seo
{"title":"Therapeutic Drug Monitoring of 6 New-Generation Antiseizure Medications Using a Mass Spectrometry Method: Analysis of 2-Year Experience in a Large Cohort of Korean Epilepsy Patients.","authors":"Sang-Mi Kim, Won Young Heo, Hyeonju Oh, Eun Yeon Joo, Young-Min Shon, S. Hong, Soo-Youn Lee, Dae-Won Seo","doi":"10.5858/arpa.2023-0386-OA","DOIUrl":null,"url":null,"abstract":"CONTEXT.—\nNew-generation antiseizure medications (ASMs) are increasingly prescribed, and therapeutic drug monitoring (TDM) has been proposed to improve clinical outcome. However, clinical TDM data on new-generation ASMs are scarce.\n\n\nOBJECTIVE.—\nTo develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for therapeutic drug monitoring (TDM) of 6 new-generation ASMs in serum and analyze the clinical TDM data from a large cohort of Korean patients with epilepsy.\n\n\nDESIGN.—\nStable isotope-labeled internal standards were added to protein precipitations of serum. One microliter of sample was separated on Agilent Poroshell EC-C18 column, and lacosamide, perampanel, gabapentin, pregabalin, vigabatrin, and rufinamide were simultaneously quantified by Agilent 6460 triple-quad mass spectrometer in multiple-reaction monitoring mode. Linearity, sensitivity, precision, accuracy, specificity, carryover, extraction recovery, and matrix effect were evaluated. TDM data of 458 samples from 363 Korean epilepsy patients were analyzed.\n\n\nRESULTS.—\nThe method was linear with limit of detection less than 0.05 μg/mL in all analytes. Intraassay and interassay imprecisions were less than 5% coefficient of variation. Accuracy was within ±15% bias. Extraction recovery ranged from 85.9% to 98.8%. A total of 88% (403 of 458) were on polypharmacy, with 29% (118 of 403) using concomitant enzyme inducers. Only 38% (175 of 458) of the concentrations were therapeutic, with 53% (244 of 458) being subtherapeutic. Drug concentration and concentration-to-dose ratio were highly variable among individuals in all 6 ASMs.\n\n\nCONCLUSIONS.—\nA simple and rapid LC-MS/MS method for TDM of 6 ASMs was developed and successfully applied to clinical practice. This large-scale TDM data could help establish an effective monitoring strategy for these drugs.","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":"5 3","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5858/arpa.2023-0386-OA","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
CONTEXT.—
New-generation antiseizure medications (ASMs) are increasingly prescribed, and therapeutic drug monitoring (TDM) has been proposed to improve clinical outcome. However, clinical TDM data on new-generation ASMs are scarce.
OBJECTIVE.—
To develop and validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for therapeutic drug monitoring (TDM) of 6 new-generation ASMs in serum and analyze the clinical TDM data from a large cohort of Korean patients with epilepsy.
DESIGN.—
Stable isotope-labeled internal standards were added to protein precipitations of serum. One microliter of sample was separated on Agilent Poroshell EC-C18 column, and lacosamide, perampanel, gabapentin, pregabalin, vigabatrin, and rufinamide were simultaneously quantified by Agilent 6460 triple-quad mass spectrometer in multiple-reaction monitoring mode. Linearity, sensitivity, precision, accuracy, specificity, carryover, extraction recovery, and matrix effect were evaluated. TDM data of 458 samples from 363 Korean epilepsy patients were analyzed.
RESULTS.—
The method was linear with limit of detection less than 0.05 μg/mL in all analytes. Intraassay and interassay imprecisions were less than 5% coefficient of variation. Accuracy was within ±15% bias. Extraction recovery ranged from 85.9% to 98.8%. A total of 88% (403 of 458) were on polypharmacy, with 29% (118 of 403) using concomitant enzyme inducers. Only 38% (175 of 458) of the concentrations were therapeutic, with 53% (244 of 458) being subtherapeutic. Drug concentration and concentration-to-dose ratio were highly variable among individuals in all 6 ASMs.
CONCLUSIONS.—
A simple and rapid LC-MS/MS method for TDM of 6 ASMs was developed and successfully applied to clinical practice. This large-scale TDM data could help establish an effective monitoring strategy for these drugs.
期刊介绍:
ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric.
Indexed/Abstracted:
Web of Science SCIE
Scopus
CAS
INSPEC
Portico