Shedding Light on the Failure Factors of Subsea Critical Fastener Bolts

O. Medlinsky, Constantinos Hadjistassou, Amir Eliezer
{"title":"Shedding Light on the Failure Factors of Subsea Critical Fastener Bolts","authors":"O. Medlinsky, Constantinos Hadjistassou, Amir Eliezer","doi":"10.1149/2754-2734/ad3a7c","DOIUrl":null,"url":null,"abstract":"\n Offshore facilities, such as oil and gas rigs, wind turbines, and related subsea equipment, typically use flanges fastened using bolts and nuts as the main connectors. In this study, multidisciplinary parameters, namely the preload torque used to tighten bolts, simulated subsea water currents, water temperature, and impressed current cathodic protection, were applied to ASTM A193 B7 bolts. An experimental supervisory control and data acquisition system was designed to obtain measurements every 5 min throughout a 21-day experiment. Finite element analysis was performed to predict the structurally vulnerable areas of the bolts. A strong correlation was found between the reference electrode readings and the measured electrical current, tightening torque, and water temperature. As the water temperature rises during the day, the reference electrode reading becomes less negative and the electrical current decreases. Subsea water currents cause about a four-time increase in the bolt corrosion rate, with unprotected bolts suffering a nine-time-higher corrosion rate than protected bolts. A unique supply–demand interaction is observed; less protection is supplied to areas with lower corrosion rates (lower demand for protection). Finally, scanning electron microscopy examination reveals new insights into the failure mechanisms of subsea bolts.","PeriodicalId":489350,"journal":{"name":"ECS advances","volume":"31 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS advances","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.1149/2754-2734/ad3a7c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Offshore facilities, such as oil and gas rigs, wind turbines, and related subsea equipment, typically use flanges fastened using bolts and nuts as the main connectors. In this study, multidisciplinary parameters, namely the preload torque used to tighten bolts, simulated subsea water currents, water temperature, and impressed current cathodic protection, were applied to ASTM A193 B7 bolts. An experimental supervisory control and data acquisition system was designed to obtain measurements every 5 min throughout a 21-day experiment. Finite element analysis was performed to predict the structurally vulnerable areas of the bolts. A strong correlation was found between the reference electrode readings and the measured electrical current, tightening torque, and water temperature. As the water temperature rises during the day, the reference electrode reading becomes less negative and the electrical current decreases. Subsea water currents cause about a four-time increase in the bolt corrosion rate, with unprotected bolts suffering a nine-time-higher corrosion rate than protected bolts. A unique supply–demand interaction is observed; less protection is supplied to areas with lower corrosion rates (lower demand for protection). Finally, scanning electron microscopy examination reveals new insights into the failure mechanisms of subsea bolts.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
揭示海底关键紧固件螺栓的失效因素
石油和天然气钻井平台、风力涡轮机和相关海底设备等海上设施通常使用螺栓和螺母作为主要连接件紧固法兰。在本研究中,对 ASTM A193 B7 螺栓采用了多学科参数,即拧紧螺栓时使用的预紧扭矩、模拟海底水流、水温和冲击电流阴极保护。设计了一个实验监督控制和数据采集系统,以便在 21 天的实验中每 5 分钟获得一次测量结果。通过有限元分析预测螺栓的结构脆弱区域。结果发现,参比电极读数与测得的电流、拧紧扭矩和水温之间存在很强的相关性。随着白天水温的升高,参比电极读数的负值减小,电流也随之减小。海底水流导致螺栓腐蚀率增加约四倍,未受保护螺栓的腐蚀率比受保护螺栓高出九倍。观察到了一种独特的供需互动现象;向腐蚀率较低的区域提供的保护较少(对保护的需求较低)。最后,扫描电子显微镜检查揭示了海底螺栓失效机制的新见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Communication — The Impact of Co-solvent Selection for Dimethyl-2,5-dioxahexane carboxylate in Sodium Ion Batteries La-based Transition Metal Oxide Perovskites as Electrocatalysts for Electrochemical Carbon Dioxide Reduction Exhaustive Study of Electrical Conductivity in the MNb2-xTixO6-0.5x (M = Mg, Ca, Zn; x = 0, 0.1, 0.2) Columbites Oscillating Oxygen Concentration Transport through PEM Fuel Cell Gas Diffusion Layer: Variation of the Phase Angle Shedding Light on the Failure Factors of Subsea Critical Fastener Bolts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1