CPV Monitoring - Optimization of Control Chart Design by Reducing the False Alarm Rate and Nuisance Signal

Naveenganesh Muralidharan, Thatsinee Johnson, Leyla Rose, Mark Davis
{"title":"CPV Monitoring - Optimization of Control Chart Design by Reducing the False Alarm Rate and Nuisance Signal","authors":"Naveenganesh Muralidharan, Thatsinee Johnson, Leyla Rose, Mark Davis","doi":"10.11648/j.sjams.20241202.11","DOIUrl":null,"url":null,"abstract":"The Food and Drug Administration’s 2011 Process Validation Guidance and International Council for Harmonization Quality Guidelines recommend continued process verification (CPV) as a mandatory requirement for pharmaceutical, biopharmaceutical, and other regulated industries. As a part of product life cycle management, after process characterization in stage 1 and process qualification and validation in stage-2, CPV is performed as stage-3 validation during commercial manufacturing. CPV ensures that the process continues to remain within a validated state. CPV requires the collection and analysis of data related to critical quality attributes, critical material attributes, and critical process parameters on a minimum basis. Data is then used to elucidate process control regarding the capability to meet predefined specifications and stability via statistical process control (SPC) tools. In SPC, the control charts and Nelson rules are commonly used throughout the industry to monitor and trend data to ensure that a process remains in control. However, basic control charts are susceptible to false alarms and nuisance alarms. Therefore, it is imperative to understand the assumptions behind control charts and the inherent false alarm rates for different Nelson rules. In this article, the authors have detailed the assumptions behind the usage of control charts, the rate of false alarms for different Nelson rules, the impact of skewness and kurtosis of a data distribution on the false alarm rate, and methods for optimizing control chart design by reducing false alarm rates and nuisance signals.","PeriodicalId":422938,"journal":{"name":"Science Journal of Applied Mathematics and Statistics","volume":"82 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science Journal of Applied Mathematics and Statistics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/j.sjams.20241202.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Food and Drug Administration’s 2011 Process Validation Guidance and International Council for Harmonization Quality Guidelines recommend continued process verification (CPV) as a mandatory requirement for pharmaceutical, biopharmaceutical, and other regulated industries. As a part of product life cycle management, after process characterization in stage 1 and process qualification and validation in stage-2, CPV is performed as stage-3 validation during commercial manufacturing. CPV ensures that the process continues to remain within a validated state. CPV requires the collection and analysis of data related to critical quality attributes, critical material attributes, and critical process parameters on a minimum basis. Data is then used to elucidate process control regarding the capability to meet predefined specifications and stability via statistical process control (SPC) tools. In SPC, the control charts and Nelson rules are commonly used throughout the industry to monitor and trend data to ensure that a process remains in control. However, basic control charts are susceptible to false alarms and nuisance alarms. Therefore, it is imperative to understand the assumptions behind control charts and the inherent false alarm rates for different Nelson rules. In this article, the authors have detailed the assumptions behind the usage of control charts, the rate of false alarms for different Nelson rules, the impact of skewness and kurtosis of a data distribution on the false alarm rate, and methods for optimizing control chart design by reducing false alarm rates and nuisance signals.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CPV 监测 - 通过降低误报率和干扰信号优化控制图设计
美国食品和药物管理局 2011 年《工艺验证指南》和国际协调理事会《质量准则》建议将持续工艺验证 (CPV) 作为制药、生物制药和其他受监管行业的一项强制性要求。作为产品生命周期管理的一部分,在第一阶段的工艺特征描述和第二阶段的工艺鉴定和验证之后,CPV 作为第三阶段的验证在商业生产过程中执行。CPV 可确保工艺继续保持在验证状态。CPV 要求至少收集和分析与关键质量属性、关键材料属性和关键工艺参数有关的数据。然后,通过统计过程控制(SPC)工具,利用数据阐明与满足预定规格和稳定性的能力有关的过程控制。在 SPC 中,控制图和纳尔逊规则在整个行业中被普遍用于监测和趋势分析数据,以确保过程始终处于控制之中。然而,基本控制图容易出现误报和骚扰报警。因此,必须了解控制图背后的假设以及不同纳尔逊规则固有的误报率。在本文中,作者详细介绍了使用控制图背后的假设、不同纳尔逊规则的误报率、数据分布的偏度和峰度对误报率的影响,以及通过降低误报率和干扰信号来优化控制图设计的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimization of the Non-Linear Diffussion Equations CPV Monitoring - Optimization of Control Chart Design by Reducing the False Alarm Rate and Nuisance Signal On Different Extraction Methods of Factor Analysis Improvement of the Raabe-Duhamel Convergence Criterion Generalized Volatility Modelling of Stock Returns of Selected Nigerian Oil and Gas Companies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1