Characterization of thin carbonated LGADs after irradiation up to 2.5· 1015 n1 Mev eq./cm2

R. Mulargia, R. Arcidiacono, G. Borghi, M. Boscardin, N. Cartiglia, M. Centis Vignalis, M. Costa, T. Croci, M. Ferrero, F. Ficorella, A. Fondacci, S. Giordanengo, O. Hammad Ali, C. Hanna, L. Lanteri, L. Menzio, V. Monaco, A. Morozzi, F. Moscatelli, D. Passeri, N. Pastrone, G. Paternoster, F. Siviero, R.S. White, V. Sola
{"title":"Characterization of thin carbonated LGADs after irradiation up to 2.5· 1015 n1 Mev eq./cm2","authors":"R. Mulargia, R. Arcidiacono, G. Borghi, M. Boscardin, N. Cartiglia, M. Centis Vignalis, M. Costa, T. Croci, M. Ferrero, F. Ficorella, A. Fondacci, S. Giordanengo, O. Hammad Ali, C. Hanna, L. Lanteri, L. Menzio, V. Monaco, A. Morozzi, F. Moscatelli, D. Passeri, N. Pastrone, G. Paternoster, F. Siviero, R.S. White, V. Sola","doi":"10.1088/1748-0221/19/04/c04022","DOIUrl":null,"url":null,"abstract":"\n EXFLU1 is a new batch of radiation-resistant silicon sensors manufactured at Fondazione Bruno Kessler (FBK, Italy).\nThe EXFLU1 sensors utilize thin substrates that remain operable even after extensive irradiation. They incorporate Low-Gain Avalanche Diode (LGAD) technology, enabling internal multiplication of charge carriers to boost the small signal produced by a particle crossing their thin active thicknesses, ranging from 15 to 45 μ m.\nTo address current challenges related to acceptor removal, the EXFLU1 production incorporates improved defect engineering techniques. This includes the so called carbonated LGADs, where carbon doping is implanted alongside boron in the gain layer. This contribution focuses on evaluating the performances of thin sensors with carbonated gain layer from the EXFLU1 production, before and after irradiation up to 2.5· 1015 n1 Mev eq./cm2.\nThe conducted tests involve static and transient characterizations, including I-V and C-V measurements, as well as laser and β-source tests.\nThis work aims to present the state of the art in LGAD sensor technology with a carbonated gain layer and shows the characterization of the most radiation-resistant LGAD sensors produced to date.","PeriodicalId":507814,"journal":{"name":"Journal of Instrumentation","volume":"283 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/19/04/c04022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

EXFLU1 is a new batch of radiation-resistant silicon sensors manufactured at Fondazione Bruno Kessler (FBK, Italy). The EXFLU1 sensors utilize thin substrates that remain operable even after extensive irradiation. They incorporate Low-Gain Avalanche Diode (LGAD) technology, enabling internal multiplication of charge carriers to boost the small signal produced by a particle crossing their thin active thicknesses, ranging from 15 to 45 μ m. To address current challenges related to acceptor removal, the EXFLU1 production incorporates improved defect engineering techniques. This includes the so called carbonated LGADs, where carbon doping is implanted alongside boron in the gain layer. This contribution focuses on evaluating the performances of thin sensors with carbonated gain layer from the EXFLU1 production, before and after irradiation up to 2.5· 1015 n1 Mev eq./cm2. The conducted tests involve static and transient characterizations, including I-V and C-V measurements, as well as laser and β-source tests. This work aims to present the state of the art in LGAD sensor technology with a carbonated gain layer and shows the characterization of the most radiation-resistant LGAD sensors produced to date.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经过高达 2.5- 1015 n1 Mev eq./cm2 的辐照后碳化 LGAD 薄层的表征
EXFLU1 是布鲁诺-凯斯勒基金会(FBK,意大利)生产的一批新型抗辐射硅传感器。它们采用了低增益雪崩二极管(LGAD)技术,实现了电荷载流子的内部倍增,以增强粒子穿过其薄薄的活性厚度(15 至 45 μ m)时产生的微小信号。这包括所谓的碳化 LGAD,即在增益层中掺入碳和硼。这项研究的重点是评估 EXFLU1 生产的带有碳化增益层的薄型传感器在 2.5- 1015 n1 Mev eq./cm2 辐照前后的性能。所进行的测试包括静态和瞬态表征,包括 I-V 和 C-V 测量,以及激光和 β 源测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identification of material by X-ray fluorescence analysis with a pyroelectric X-ray generator Quasi-continuous re-binning of measured spectra and associated uncertainties Implementation of energy reduced 90Sr/90Y radiation fields, or: Propagation of beta radiation, a case study Evaluation of the activation of the radiation shielding of the LaDiff neutron triple-axis-spectrometer at FRM-II by simulation/calculation Calculation of efficiency and resolution of a hexagonal NaI(Tl) detector as a function of source position
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1