{"title":"Intraoperative changes to the components planned preoperatively do not affect short-term, postoperative clinical outcomes after reverse total shoulder arthroplasty","authors":"","doi":"10.1053/j.sart.2024.03.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Three-dimensional, computed tomography<span> preoperative planning has been increasingly adopted among shoulder arthroplasty<span> surgeons. Prior studies have not examined outcomes in patients undergoing reverse total shoulder arthroplasty in which the surgeon implanted prostheses that deviated from the preoperative plan compared to patients in which the surgeon followed the preoperative plan. The hypothesis of this study was that clinical outcomes would not be different between patients in which the surgeon utilized components that deviated from those predicted in the preoperative plan and patients in which the surgeon followed the preoperative plan.</span></span></p></div><div><h3>Methods</h3><p>A retrospective review of patients that had preoperative planning for reverse total shoulder arthroplasty<span> from April 2017 through February 2022 was performed. Patients were stratified into two groups: patients in which the surgeon utilized components that deviated from those anticipated by the preoperative plan (changed group), and patients in which the surgeon utilized all of the components anticipated by the preoperative plan (as planned group). Patient-reported outcomes including the Western Ontario Osteoarthritis<span> Index, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Shoulder Activity Level were recorded preoperatively, at one year, and at two years. Preoperative and one-year postoperative range of motion was recorded.</span></span></p></div><div><h3>Results</h3><p>One hundred and eighty-nine patients were included in this study. One hundred forty-seven patients had intraoperative changes to their preoperative plan and 42 patients underwent reverse total arthroplasty without changes to their preoperative plan. There was no difference determined between any patient-reported outcome score at the one- and two-year postoperative time points between the as planned group and the changed group. No differences were found in range of motion between groups. Patients initially planned to undergo anatomic total shoulder arthroplasty that were intraoperatively converted to a reverse total shoulder arthroplasty had equivalent outcomes compared to those that had 1) other intraoperative deviations or 2) had no changes to their original preoperative plan.</p></div><div><h3>Conclusion</h3><p>Patients undergoing reverse total shoulder arthroplasty that had an intraoperative deviation to the components utilized in the preoperative plan had equivalent 1) patient-reported outcomes at one and two years after surgery and 2) range of motion one year after surgery compared to those that did not change from the preoperative plan. This study suggests it is safe to make intraoperative changes to the components utilized in the preoperative plan without concern for inferior postoperative outcomes when performing reverse total shoulder arthroplasty.</p></div>","PeriodicalId":39885,"journal":{"name":"Seminars in Arthroplasty","volume":"34 3","pages":"Pages 585-592"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1045452724000397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Three-dimensional, computed tomography preoperative planning has been increasingly adopted among shoulder arthroplasty surgeons. Prior studies have not examined outcomes in patients undergoing reverse total shoulder arthroplasty in which the surgeon implanted prostheses that deviated from the preoperative plan compared to patients in which the surgeon followed the preoperative plan. The hypothesis of this study was that clinical outcomes would not be different between patients in which the surgeon utilized components that deviated from those predicted in the preoperative plan and patients in which the surgeon followed the preoperative plan.

Methods

A retrospective review of patients that had preoperative planning for reverse total shoulder arthroplasty from April 2017 through February 2022 was performed. Patients were stratified into two groups: patients in which the surgeon utilized components that deviated from those anticipated by the preoperative plan (changed group), and patients in which the surgeon utilized all of the components anticipated by the preoperative plan (as planned group). Patient-reported outcomes including the Western Ontario Osteoarthritis Index, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Shoulder Activity Level were recorded preoperatively, at one year, and at two years. Preoperative and one-year postoperative range of motion was recorded.

Results

One hundred and eighty-nine patients were included in this study. One hundred forty-seven patients had intraoperative changes to their preoperative plan and 42 patients underwent reverse total arthroplasty without changes to their preoperative plan. There was no difference determined between any patient-reported outcome score at the one- and two-year postoperative time points between the as planned group and the changed group. No differences were found in range of motion between groups. Patients initially planned to undergo anatomic total shoulder arthroplasty that were intraoperatively converted to a reverse total shoulder arthroplasty had equivalent outcomes compared to those that had 1) other intraoperative deviations or 2) had no changes to their original preoperative plan.

Conclusion

Patients undergoing reverse total shoulder arthroplasty that had an intraoperative deviation to the components utilized in the preoperative plan had equivalent 1) patient-reported outcomes at one and two years after surgery and 2) range of motion one year after surgery compared to those that did not change from the preoperative plan. This study suggests it is safe to make intraoperative changes to the components utilized in the preoperative plan without concern for inferior postoperative outcomes when performing reverse total shoulder arthroplasty.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
术中更改术前计划的组件不会影响反向全肩关节置换术后的短期临床效果
背景肩关节置换外科医生越来越多地采用三维计算机断层扫描术前计划。与按照术前计划植入假体的患者相比,接受反向全肩关节置换术的外科医生植入了偏离术前计划的假体,而接受全肩关节置换术的患者接受了术前计划植入的假体。本研究的假设是,如果外科医生使用的组件偏离术前计划中预测的组件,那么患者的临床结果与外科医生遵循术前计划的患者没有差异。方法对2017年4月至2022年2月期间进行反向全肩关节置换术术前计划的患者进行回顾性研究。患者被分为两组:外科医生使用的组件偏离术前计划预期的患者(改变组)和外科医生使用术前计划预期的所有组件的患者(按计划组)。患者报告的结果包括西安大略骨关节炎指数、美国肩肘外科医生评分、单次评估数字评价、简单肩关节测试和肩关节活动水平,分别在术前、术后一年和两年进行记录。记录了术前和术后一年的活动范围。147名患者在术中对术前计划进行了更改,42名患者在未更改术前计划的情况下接受了反向全关节成形术。在术后一年和两年的时间点上,按计划组和改变计划组的患者报告结果评分均无差异。两组患者的活动范围也没有差异。最初计划接受解剖型全肩关节置换术的患者在术中转为反向全肩关节置换术,与1)术中出现其他偏差或2)术前未改变原计划的患者相比,结果相当。结论与未改变术前计划的患者相比,接受反向全肩关节置换术的患者在术中偏离了术前计划中使用的组件,1)术后一年和两年的患者报告结果与2)术后一年的活动范围与未改变术前计划的患者结果相当。这项研究表明,在进行反向全肩关节置换术时,对术前计划中使用的组件进行术中更改是安全的,无需担心术后效果不佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Seminars in Arthroplasty
Seminars in Arthroplasty Medicine-Surgery
CiteScore
1.00
自引率
0.00%
发文量
104
期刊介绍: Each issue of Seminars in Arthroplasty provides a comprehensive, current overview of a single topic in arthroplasty. The journal addresses orthopedic surgeons, providing authoritative reviews with emphasis on new developments relevant to their practice.
期刊最新文献
Editorial Board Table of Contents Comparing comorbidity burden between patients undergoing ambulatory rotator cuff repair vs. inpatient anatomic total shoulder arthroplasty Reaching MCID, SCB, and PASS for ASES, SANE, SST, and VAS following shoulder arthroplasty does not correlate with patient satisfaction Anatomic total shoulder arthroplasty using hybrid glenoid fixation with a porous-coated titanium post. Two- to ten-year follow-up of 256 cases with primary glenohumeral osteoarthritis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1