Comparación de medios de cultivo para la detección de Legionella spp. en muestras de agua sanitaria: adaptación a la norma ISO 11731:2017

IF 2.6 4区 医学 Q3 INFECTIOUS DISEASES Enfermedades infecciosas y microbiologia clinica Pub Date : 2024-08-01 DOI:10.1016/j.eimc.2024.03.013
{"title":"Comparación de medios de cultivo para la detección de Legionella spp. en muestras de agua sanitaria: adaptación a la norma ISO 11731:2017","authors":"","doi":"10.1016/j.eimc.2024.03.013","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Water sample culturing is the reference method to detect <em>Legionella</em> spp. in sanitary facilities. Until 2017, UNE-EN ISO 11731 only included the GVPC medium, which inhibits interfering microbiota but hinders the growth of <em>Legionella</em> spp. To improve its recovery, the new standard incorporates the BCYE medium into the working protocol.</p></div><div><h3>Methods</h3><p>We inoculated 1,306 sanitary water samples onto BCYE and GVPC according to an accredited internal procedure. We compared the number of cfu/L of <em>Legionella</em> spp. detected in both media.</p></div><div><h3>Results</h3><p>The median in BCYE was 2,000<!--> <!-->cfu/L higher than in GVPC (p<!--> <!-->=<!--> <!-->0.000). In the presence of high amounts of interfering microbiota, both media were similar; in the absence or low interfering microbiota BCYE was four times more sensitive than GVPC (p<!--> <!-->=<!--> <!-->0.000).</p></div><div><h3>Conclusion</h3><p>Including BCYE in the analysis of sanitary water significantly improves the recovery of <em>Legionella</em> spp. in low contaminated samples.</p></div>","PeriodicalId":11608,"journal":{"name":"Enfermedades infecciosas y microbiologia clinica","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enfermedades infecciosas y microbiologia clinica","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0213005X24002295","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Water sample culturing is the reference method to detect Legionella spp. in sanitary facilities. Until 2017, UNE-EN ISO 11731 only included the GVPC medium, which inhibits interfering microbiota but hinders the growth of Legionella spp. To improve its recovery, the new standard incorporates the BCYE medium into the working protocol.

Methods

We inoculated 1,306 sanitary water samples onto BCYE and GVPC according to an accredited internal procedure. We compared the number of cfu/L of Legionella spp. detected in both media.

Results

The median in BCYE was 2,000 cfu/L higher than in GVPC (p = 0.000). In the presence of high amounts of interfering microbiota, both media were similar; in the absence or low interfering microbiota BCYE was four times more sensitive than GVPC (p = 0.000).

Conclusion

Including BCYE in the analysis of sanitary water significantly improves the recovery of Legionella spp. in low contaminated samples.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于检测卫生水样中军团菌属的培养基比较:ISO 11731:2017 适应版
引言水样培养是检测卫生设施中军团菌属的参考方法。在 2017 年之前,UNE-EN ISO 11731 仅包括 GVPC 培养基,该培养基可抑制干扰微生物群,但阻碍军团菌的生长。为了提高其回收率,新标准将 BCYE 培养基纳入了工作方案。结果 BCYE 中的中位数比 GVPC 中高 2000 cfu/L(p = 0.000)。在存在大量干扰微生物群的情况下,两种培养基的灵敏度相似;在没有干扰微生物群或干扰微生物群较少的情况下,BCYE 的灵敏度是 GVPC 的四倍(p = 0.000)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.10
自引率
8.00%
发文量
194
审稿时长
29 days
期刊介绍: Hoy está universalmente reconocida la renovada y creciente importancia de la patología infecciosa: aparición de nuevos agentes patógenos, de cepas resistentes, de procesos con expresión clínica hasta ahora desconocida, de cuadros de una gran complejidad. Paralelamente, la Microbiología y la Infectología Clínicas han experimentado un gran desarrollo como respuesta al reto planteado por la actual patología infecciosa. Enfermedades Infecciosas y Microbiología Clínica es la Publicación Oficial de la Sociedad Española SEIMC. Cumple con la garantía científica de esta Sociedad, la doble función de difundir trabajos de investigación, tanto clínicos como microbiológicos, referidos a la patología infecciosa, y contribuye a la formación continuada de los interesados en aquella patología mediante artículos orientados a ese fin y elaborados por autores de la mayor calificación invitados por la revista.
期刊最新文献
Consideraciones sobre la aplicación del plan formativo de Microbiología y Parasitología clínica en los hospitales de España: una encuesta nacional Caracterización de la reinfección de prótesis articular tras recambio en 2 tiempos (infección de la prótesis del 2.o tiempo). Un estudio multicéntrico Tendencia en la vacunación en personas con infección por VIH participantes en la Encuesta Hospitalaria de pacientes con VIH, 2006-2021 Drug burden index in people living with HIV over 50 years of age in a real clinical practice cohort Intertrigo inguinal: ¿infeccioso o inflamatorio?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1