{"title":"Comparación de medios de cultivo para la detección de Legionella spp. en muestras de agua sanitaria: adaptación a la norma ISO 11731:2017","authors":"","doi":"10.1016/j.eimc.2024.03.013","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Water sample culturing is the reference method to detect <em>Legionella</em> spp. in sanitary facilities. Until 2017, UNE-EN ISO 11731 only included the GVPC medium, which inhibits interfering microbiota but hinders the growth of <em>Legionella</em> spp. To improve its recovery, the new standard incorporates the BCYE medium into the working protocol.</p></div><div><h3>Methods</h3><p>We inoculated 1,306 sanitary water samples onto BCYE and GVPC according to an accredited internal procedure. We compared the number of cfu/L of <em>Legionella</em> spp. detected in both media.</p></div><div><h3>Results</h3><p>The median in BCYE was 2,000<!--> <!-->cfu/L higher than in GVPC (p<!--> <!-->=<!--> <!-->0.000). In the presence of high amounts of interfering microbiota, both media were similar; in the absence or low interfering microbiota BCYE was four times more sensitive than GVPC (p<!--> <!-->=<!--> <!-->0.000).</p></div><div><h3>Conclusion</h3><p>Including BCYE in the analysis of sanitary water significantly improves the recovery of <em>Legionella</em> spp. in low contaminated samples.</p></div>","PeriodicalId":11608,"journal":{"name":"Enfermedades infecciosas y microbiologia clinica","volume":"42 7","pages":"Pages 373-376"},"PeriodicalIF":2.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enfermedades infecciosas y microbiologia clinica","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0213005X24002295","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Water sample culturing is the reference method to detect Legionella spp. in sanitary facilities. Until 2017, UNE-EN ISO 11731 only included the GVPC medium, which inhibits interfering microbiota but hinders the growth of Legionella spp. To improve its recovery, the new standard incorporates the BCYE medium into the working protocol.
Methods
We inoculated 1,306 sanitary water samples onto BCYE and GVPC according to an accredited internal procedure. We compared the number of cfu/L of Legionella spp. detected in both media.
Results
The median in BCYE was 2,000 cfu/L higher than in GVPC (p = 0.000). In the presence of high amounts of interfering microbiota, both media were similar; in the absence or low interfering microbiota BCYE was four times more sensitive than GVPC (p = 0.000).
Conclusion
Including BCYE in the analysis of sanitary water significantly improves the recovery of Legionella spp. in low contaminated samples.
期刊介绍:
Hoy está universalmente reconocida la renovada y creciente importancia de la patología infecciosa: aparición de nuevos agentes patógenos, de cepas resistentes, de procesos con expresión clínica hasta ahora desconocida, de cuadros de una gran complejidad. Paralelamente, la Microbiología y la Infectología Clínicas han experimentado un gran desarrollo como respuesta al reto planteado por la actual patología infecciosa. Enfermedades Infecciosas y Microbiología Clínica es la Publicación Oficial de la Sociedad Española SEIMC. Cumple con la garantía científica de esta Sociedad, la doble función de difundir trabajos de investigación, tanto clínicos como microbiológicos, referidos a la patología infecciosa, y contribuye a la formación continuada de los interesados en aquella patología mediante artículos orientados a ese fin y elaborados por autores de la mayor calificación invitados por la revista.