{"title":"Characterisation of Redlen HF-CdZnTe at > 106 ph s-1 mm-2 using HEXITECMHz","authors":"B. Cline, D. Banks, S. Bell, I. Church, A. Davis, T. Gardiner, J. Harris, M. Hart, L. Jones, T. Nicholls, J. Nobes, S. Pradeep, M. Roberts, D. Sole, M. C. Veale, M. Wilson, V. Dhamgaye, O. Fox, K. Sawhney","doi":"10.1088/1748-0221/19/04/p04028","DOIUrl":null,"url":null,"abstract":"\n In this paper, results are presented from the\n characterisation of Redlen Technologies high-flux-capable Cadmium\n Zinc Telluride (HF-CZT) hybridised to the HEXITECMHz \n ASIC, a novel 1 MHz continuous X-ray imaging system. A 2 mm thick\n HF-CZT HEXITECMHz detector was characterised on the B16\n Test Beamline at the Diamond Light Source and displayed an average\n FWHM of 850 eV for monochromatic X-rays of energy\n 20 keV. Measurements revealed a shift in the baseline of\n irradiated pixels that results in a movement of the entire spectrum\n to higher ADU values. Datasets taken to analyse the effect's\n dynamics showed it to be highly localised and flux-dependent, with\n the excess leakage current generated equivalent to per-pixel shifts\n of ∼ 543 pA (8.68 nA mm-2) at a flux of\n 1.26×107 ph s-1 mm-2. Comparison to results\n from a p-type Si HEXITECMHz device indicate this `excess\n leakage-current' effect is unique to HF-CZT and it is hypothesised\n that it originates from trapping at the electrode-CZT interface and\n a temporary modification of the potential barrier between the CZT\n and metal electrode.","PeriodicalId":507814,"journal":{"name":"Journal of Instrumentation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/19/04/p04028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, results are presented from the characterisation of Redlen Technologies high-flux-capable Cadmium Zinc Telluride (HF-CZT) hybridised to the HEXITECMHz  ASIC, a novel 1 MHz continuous X-ray imaging system. A 2 mm thick HF-CZT HEXITECMHz detector was characterised on the B16 Test Beamline at the Diamond Light Source and displayed an average FWHM of 850 eV for monochromatic X-rays of energy 20 keV. Measurements revealed a shift in the baseline of irradiated pixels that results in a movement of the entire spectrum to higher ADU values. Datasets taken to analyse the effect's dynamics showed it to be highly localised and flux-dependent, with the excess leakage current generated equivalent to per-pixel shifts of ∼ 543 pA (8.68 nA mm-2) at a flux of 1.26×107 ph s-1 mm-2. Comparison to results from a p-type Si HEXITECMHz device indicate this `excess leakage-current' effect is unique to HF-CZT and it is hypothesised that it originates from trapping at the electrode-CZT interface and a temporary modification of the potential barrier between the CZT and metal electrode.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 HEXITECMHz 在大于 106 ph s-1 mm-2 的条件下对 Redlen HF-CdZnTe 进行表征
本文介绍了与新型 1 MHz 连续 X 射线成像系统 HEXITECMHz ASIC 相结合的 Redlen Technologies 高通量碲锌镉(HF-CZT)的鉴定结果。钻石光源的 B16 测试光束线对厚度为 2 毫米的 HF-CZT HEXITECMHz 探测器进行了鉴定,结果表明,对于能量为 20 千伏的单色 X 射线,其平均焦距为 850 eV。测量结果显示,辐照像素的基线发生了移动,导致整个光谱向更高的 ADU 值移动。用于分析该效应动态的数据集显示,该效应具有高度局部性和通量依赖性,当通量为 1.26×107 ph s-1 mm-2 时,产生的过量泄漏电流相当于每个像素移动 ∼ 543 pA(8.68 nA mm-2)。与 p 型硅 HEXITECMHz 器件的结果比较表明,这种 "过量漏电流 "效应是高频-CZT 所独有的,并假设它源于电极-CZT 接口处的捕获以及 CZT 与金属电极之间势垒的暂时改变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identification of material by X-ray fluorescence analysis with a pyroelectric X-ray generator Quasi-continuous re-binning of measured spectra and associated uncertainties Implementation of energy reduced 90Sr/90Y radiation fields, or: Propagation of beta radiation, a case study Evaluation of the activation of the radiation shielding of the LaDiff neutron triple-axis-spectrometer at FRM-II by simulation/calculation Calculation of efficiency and resolution of a hexagonal NaI(Tl) detector as a function of source position
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1