Immediate versus early loading of immediately placed bone-level tapered dental implants with hydrophilic surface in full arch maxillary rehabilitation: A pilot randomized clinical trial with 2-year follow-up

IF 3.7 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Implant Dentistry and Related Research Pub Date : 2024-05-01 DOI:10.1111/cid.13334
Aleksa Marković, Ana Todorović, Mirko Glišić, Jovana Marković, Branislav Ilić, Bojan Janjić, Tijana Mišić, Branka Trifković, Uroš Vučić, Miodrag Šćepanović, Michel M. Dard
{"title":"Immediate versus early loading of immediately placed bone-level tapered dental implants with hydrophilic surface in full arch maxillary rehabilitation: A pilot randomized clinical trial with 2-year follow-up","authors":"Aleksa Marković,&nbsp;Ana Todorović,&nbsp;Mirko Glišić,&nbsp;Jovana Marković,&nbsp;Branislav Ilić,&nbsp;Bojan Janjić,&nbsp;Tijana Mišić,&nbsp;Branka Trifković,&nbsp;Uroš Vučić,&nbsp;Miodrag Šćepanović,&nbsp;Michel M. Dard","doi":"10.1111/cid.13334","DOIUrl":null,"url":null,"abstract":"<p>This study aimed to compare implant stabilities between the immediate and early loaded, immediately placed bone-level tapered dental implants in the maxilla and to evaluate marginal bone loss (MBL), oral health-related quality of life (OHRQoL), and patient satisfaction at a 2-year follow-up. A pilot, prospective, randomized, controlled clinical trial was conducted on 24 maxillary failing dentition patients. The bone-level tapered implants of 12 patients were immediately loaded with temporary restorations, while the other 12 patients did not receive any kind of temporization. Implant-supported screw-retained complete porcelain-fused-to-metal prostheses were delivered to all patients in the seventh postoperative week. The insertion torque values of implants assigned to the immediate and early loading groups were 33.0 ± 4.87 and 29.26 ± 8.31 Ncm, respectively. The dynamics of implant stability changes from implant placement up to a 2-year follow-up were similar for both groups (Penguin®, <i>p</i> = 0.268; Ostell®, <i>p</i> = 0.552), while the MBL was at submillimeter level. The cumulative implant survival rate was 91.80% for immediately loaded implants and 97.22% for early loaded implants, without significant difference (<i>p</i> = 0.162). The total score on the Oral Health Impact Profile questionnaire significantly decreased over time in both groups, indicating improvement in OHRQoL (<i>p</i> &lt; 0.001), and the high level of patient satisfaction remained after 2 years of function regardless of a loading protocol. Both loading protocols, immediate and early, of six immediately placed bone-level tapered dental implants are an adequate treatment choice for fixed rehabilitation of the maxillary failing dentition.</p>","PeriodicalId":50679,"journal":{"name":"Clinical Implant Dentistry and Related Research","volume":"26 4","pages":"688-703"},"PeriodicalIF":3.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Implant Dentistry and Related Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cid.13334","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

This study aimed to compare implant stabilities between the immediate and early loaded, immediately placed bone-level tapered dental implants in the maxilla and to evaluate marginal bone loss (MBL), oral health-related quality of life (OHRQoL), and patient satisfaction at a 2-year follow-up. A pilot, prospective, randomized, controlled clinical trial was conducted on 24 maxillary failing dentition patients. The bone-level tapered implants of 12 patients were immediately loaded with temporary restorations, while the other 12 patients did not receive any kind of temporization. Implant-supported screw-retained complete porcelain-fused-to-metal prostheses were delivered to all patients in the seventh postoperative week. The insertion torque values of implants assigned to the immediate and early loading groups were 33.0 ± 4.87 and 29.26 ± 8.31 Ncm, respectively. The dynamics of implant stability changes from implant placement up to a 2-year follow-up were similar for both groups (Penguin®, p = 0.268; Ostell®, p = 0.552), while the MBL was at submillimeter level. The cumulative implant survival rate was 91.80% for immediately loaded implants and 97.22% for early loaded implants, without significant difference (p = 0.162). The total score on the Oral Health Impact Profile questionnaire significantly decreased over time in both groups, indicating improvement in OHRQoL (p < 0.001), and the high level of patient satisfaction remained after 2 years of function regardless of a loading protocol. Both loading protocols, immediate and early, of six immediately placed bone-level tapered dental implants are an adequate treatment choice for fixed rehabilitation of the maxillary failing dentition.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在上颌全弓康复中,立即植入带亲水性表面的骨水平锥形种植体与提前植入种植体的比较:一项为期两年的随机临床试验
本研究旨在比较上颌即刻植入和早期植入、即刻植入骨水平锥形牙种植体之间的种植体稳定性,并评估两年随访期间的边缘骨损失(MBL)、口腔健康相关生活质量(OHRQoL)和患者满意度。我们对 24 名上颌失败牙患者进行了试点、前瞻性、随机对照临床试验。其中 12 名患者的骨水平锥形种植体立即装上了临时修复体,而另外 12 名患者没有接受任何形式的临时修复。所有患者都在术后第 7 周接受了种植体支持螺钉固位的全瓷融合金属修复体。即刻加载组和早期加载组的种植体植入扭矩值分别为(33.0 ± 4.87)和(29.26 ± 8.31)Ncm。从种植体植入到两年随访期间,两组的种植体稳定性变化动态相似(Penguin®,p = 0.268;Ostell®,p = 0.552),而 MBL 处于亚毫米水平。即刻植入种植体的累积存活率为 91.80%,早期植入种植体的累积存活率为 97.22%,无显著差异(p = 0.162)。随着时间的推移,两组患者的口腔健康影响档案问卷总分均显著下降,表明患者的口腔健康质量生活得到了改善(p <0.001)。六颗即刻植入的骨水平锥形牙种植体的即刻植入和早期植入两种植入方案都是上颌失败牙固定修复的适当治疗选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.00
自引率
13.90%
发文量
103
审稿时长
4-8 weeks
期刊介绍: The goal of Clinical Implant Dentistry and Related Research is to advance the scientific and technical aspects relating to dental implants and related scientific subjects. Dissemination of new and evolving information related to dental implants and the related science is the primary goal of our journal. The range of topics covered by the journals will include but be not limited to: New scientific developments relating to bone Implant surfaces and their relationship to the surrounding tissues Computer aided implant designs Computer aided prosthetic designs Immediate implant loading Immediate implant placement Materials relating to bone induction and conduction New surgical methods relating to implant placement New materials and methods relating to implant restorations Methods for determining implant stability A primary focus of the journal is publication of evidenced based articles evaluating to new dental implants, techniques and multicenter studies evaluating these treatments. In addition basic science research relating to wound healing and osseointegration will be an important focus for the journal.
期刊最新文献
Issue Information Featured Cover A transcrestal sinus floor elevation strategy based on a haptic robot system: An in vitro study Influence of repeated implant‐abutment manipulation on the prevalence of peri‐implant diseases in complete arch restorations. A retrospective analysis Biocompatibility and dimensional stability through the use of 3D‐printed scaffolds made by polycaprolactone and bioglass‐7: An in vitro and in vivo study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1