{"title":"Sensitive assessment of bilirubin using various color space signals derived from captured images of microfluidic paper-based analytical devices","authors":"Mohamed Farag ,&nbsp;Ashraf A. Mohamed ,&nbsp;Souad A. Elfeky ,&nbsp;Abdelnaby M. Salem","doi":"10.1016/j.talo.2024.100323","DOIUrl":null,"url":null,"abstract":"<div><p>Many neonates’ manifest hyperbilirubinemia and jaundice during the first week following birth because of bilirubin accumulation in the blood. Newborns with severe hyperbilirubinemia develop neurotoxicity. Therefore, sensitive, accurate, cost-effective, and timely determination of bilirubin levels is highly desired. Herein, we present three simple systems of bilirubin assessment based on spectrophotometric, and digital imaging tools. Image-capturing devices pose a formidable challenge to sophisticated spectrophotometers and field-monitoring devices because of their simplicity and sensitivity. The first and second systems of bilirubin assessment, in solution, relied on spectrophotometric and conventional color responses of digital images collected with conventional or android smartphone camera, with LODs of 0.060–0.082 and LOQs of 0.200–0.273 ppm bilirubin. The third system utilized a microfluidic paper-based analytical device (μ-PAD) that is patterned with a wax printer on Whatman grade-1 chromatographic papers, with linear calibration graphs of up to 2.70,s and LODs of 0.035–0.040 and LOQs of 0.117–0.133 μg bilirubin/μ-PAD.</p></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"9 ","pages":"Article 100323"},"PeriodicalIF":4.1000,"publicationDate":"2024-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666831924000377/pdfft?md5=20c559fb17bc62b1413a08e77e46e90e&pid=1-s2.0-S2666831924000377-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831924000377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Many neonates’ manifest hyperbilirubinemia and jaundice during the first week following birth because of bilirubin accumulation in the blood. Newborns with severe hyperbilirubinemia develop neurotoxicity. Therefore, sensitive, accurate, cost-effective, and timely determination of bilirubin levels is highly desired. Herein, we present three simple systems of bilirubin assessment based on spectrophotometric, and digital imaging tools. Image-capturing devices pose a formidable challenge to sophisticated spectrophotometers and field-monitoring devices because of their simplicity and sensitivity. The first and second systems of bilirubin assessment, in solution, relied on spectrophotometric and conventional color responses of digital images collected with conventional or android smartphone camera, with LODs of 0.060–0.082 and LOQs of 0.200–0.273 ppm bilirubin. The third system utilized a microfluidic paper-based analytical device (μ-PAD) that is patterned with a wax printer on Whatman grade-1 chromatographic papers, with linear calibration graphs of up to 2.70,s and LODs of 0.035–0.040 and LOQs of 0.117–0.133 μg bilirubin/μ-PAD.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用从微流控纸质分析装置捕获的图像中提取的各种色彩空间信号灵敏评估胆红素
由于胆红素在血液中蓄积,许多新生儿在出生后一周内会出现高胆红素血症和黄疸。患有严重高胆红素血症的新生儿会出现神经中毒。因此,灵敏、准确、经济、及时地测定胆红素水平是非常必要的。在此,我们介绍三种基于分光光度法和数字成像工具的简单胆红素评估系统。图像捕捉设备因其简便性和灵敏度,对复杂的分光光度计和现场监测设备构成了巨大的挑战。第一套和第二套胆红素评估系统是在溶液中利用分光光度计和传统色彩反应对传统或安卓智能手机摄像头采集的数字图像进行评估,LOD 为 0.060-0.082,LOQ 为 0.200-0.273 ppm 胆红素。第三个系统采用了微流控纸质分析装置(μ-PAD),该装置用蜡打印机在 Whatman 1 级色谱纸上绘制图案,线性校准图高达 2.70,s,最低检测限为 0.035-0.040 微克胆红素/μ-PAD,最低检测限为 0.117-0.133 微克胆红素/μ-PAD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Ultra-sensitive refractive index detection with gold-coated PCF-based SPR sensor High-sensitive ethanol gas sensor using Ag modified ZnO nanosheets High-throughput detection of bottle materials of agave spirits using 3D-printed cartridges for paper-spray ionization mass spectrometry MCM-41 based dispersive micro-solid phase extraction of selected cephalosporin antibiotic residues from water samples prior to liquid chromatographic quantification Bone fragility in Type 2 Diabetes Mellitus. Influence of sex and cardiovascular disease in a pilot study using metabolomics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1