Martin Aman, Fabian Preisner, Maximilian Mayrhofer-Schmid, Amr Eisa, Daniel Schwarz, Ulrich Kneser, Leila Harhaus, Arne H Boecker
{"title":"Inferior Long-Term Results of a Randomized Controlled Trial Initially Demonstrating Enhanced Sensory Nerve Recovery Using a Chitosan Nerve Tube.","authors":"Martin Aman, Fabian Preisner, Maximilian Mayrhofer-Schmid, Amr Eisa, Daniel Schwarz, Ulrich Kneser, Leila Harhaus, Arne H Boecker","doi":"10.1097/PRS.0000000000011526","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Traumatic peripheral nerve injuries can result in significant functional impairments and long-term sequelae. This study evaluated the long-term outcomes of a chitosan tube implant to protect epineural coaptation after peripheral nerve injuries using 2 different tube versions (different wall thicknesses and resorption characteristics), compared with a control group. The study focused on pain levels, sensory function, and overall functional outcomes.</p><p><strong>Methods: </strong>Patients who received a tube implant around direct coaptation sites of digital nerves were randomized and compared with control patients with no additional tube protection. Pain levels, sensory function, grip force, and functional scores were assessed at time points ranging from 3 months to 5 years postoperatively. Tube biodegradation was measured using high-resolution magnetic resonance neurography and categorized.</p><p><strong>Results: </strong>Patients with the first tube version had higher pain levels compared with the control group after 5 years, and reported more symptoms of numbness and hypersensitivity. Patients with the second version exhibited higher pain levels at 3 months that did not persist at 6 months, but they showed compromised sensory function, with higher 2-point discrimination values compared with the first and control groups. No differences were found in grip force or functional scores between the groups. Magnetic resonance imaging displayed remnants of implants even at long-term follow-up.</p><p><strong>Conclusions: </strong>The findings suggest potential limitations attributable to increased pain and impaired sensory function associated with tube implantation in the long term. In the short term, however, the material seemed to have a protective effect (as published previously). The resorption process was not complete at the end of the 5-year observation period. This might explain the prolonged scarring and inferior long-term results. Future research should focus on improving tube materials and design to minimize adverse effects and enhance functional outcomes.</p>","PeriodicalId":20128,"journal":{"name":"Plastic and reconstructive surgery","volume":" ","pages":"364-373"},"PeriodicalIF":3.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plastic and reconstructive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PRS.0000000000011526","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Traumatic peripheral nerve injuries can result in significant functional impairments and long-term sequelae. This study evaluated the long-term outcomes of a chitosan tube implant to protect epineural coaptation after peripheral nerve injuries using 2 different tube versions (different wall thicknesses and resorption characteristics), compared with a control group. The study focused on pain levels, sensory function, and overall functional outcomes.
Methods: Patients who received a tube implant around direct coaptation sites of digital nerves were randomized and compared with control patients with no additional tube protection. Pain levels, sensory function, grip force, and functional scores were assessed at time points ranging from 3 months to 5 years postoperatively. Tube biodegradation was measured using high-resolution magnetic resonance neurography and categorized.
Results: Patients with the first tube version had higher pain levels compared with the control group after 5 years, and reported more symptoms of numbness and hypersensitivity. Patients with the second version exhibited higher pain levels at 3 months that did not persist at 6 months, but they showed compromised sensory function, with higher 2-point discrimination values compared with the first and control groups. No differences were found in grip force or functional scores between the groups. Magnetic resonance imaging displayed remnants of implants even at long-term follow-up.
Conclusions: The findings suggest potential limitations attributable to increased pain and impaired sensory function associated with tube implantation in the long term. In the short term, however, the material seemed to have a protective effect (as published previously). The resorption process was not complete at the end of the 5-year observation period. This might explain the prolonged scarring and inferior long-term results. Future research should focus on improving tube materials and design to minimize adverse effects and enhance functional outcomes.
期刊介绍:
For more than 70 years Plastic and Reconstructive Surgery® has been the one consistently excellent reference for every specialist who uses plastic surgery techniques or works in conjunction with a plastic surgeon. Plastic and Reconstructive Surgery® , the official journal of the American Society of Plastic Surgeons, is a benefit of Society membership, and is also available on a subscription basis.
Plastic and Reconstructive Surgery® brings subscribers up-to-the-minute reports on the latest techniques and follow-up for all areas of plastic and reconstructive surgery, including breast reconstruction, experimental studies, maxillofacial reconstruction, hand and microsurgery, burn repair, cosmetic surgery, as well as news on medicolegal issues. The cosmetic section provides expanded coverage on new procedures and techniques and offers more cosmetic-specific content than any other journal. All subscribers enjoy full access to the Journal''s website, which features broadcast quality videos of reconstructive and cosmetic procedures, podcasts, comprehensive article archives dating to 1946, and additional benefits offered by the newly-redesigned website.