Hikari Fujii , Saeid Mohammadzadeh Bina , Nanami Sato , Takeshi Ishihara
{"title":"Evaluating tidal impact on ground source heat exchanger performance under fluctuating groundwater levels","authors":"Hikari Fujii , Saeid Mohammadzadeh Bina , Nanami Sato , Takeshi Ishihara","doi":"10.1016/j.geothermics.2024.103050","DOIUrl":null,"url":null,"abstract":"<div><p>Coastal regions undergo dynamic changes due to tidal forces, posing distinct challenges for groundwater management and utilization of ground source heat pump (GSHP) systems. This study examines the impact of tidal fluctuations on groundwater levels and the performance of ground heat exchangers (GHEs), specifically focusing on the suitability of horizontal directional drilling (HDD) technology in high-tidal zones. Itoman City in Okinawa Prefecture, Southern Japan, serves as an ideal location for this study due to its complex coastal hydrogeological conditions and increasing interest in renewable energy solutions. Employing a comprehensive approach involving field experiments, FEFLOW software simulations, and model validation, we aim to elucidate the intricate relationship between tidal dynamics, groundwater behavior, and GHE performance. Furthermore, our investigation assesses the effectiveness of HDD-GHEs installed in highly tidal-affected zones to determine the optimal installation depth for this type of GHE in coastal regions. According to our research, the layer at a depth of 30 m is most affected by tidal influence and fluctuations in groundwater levels in coastal regions. This layer is the most suitable for installing horizontal HDD-GHEs, with an average heat exchange rate of about 89 W/m. This rate is approximately four and two times higher than the depths above and below this layer, respectively, due to groundwater saturation and flow in the formation. Furthermore, we noticed that the heat exchange rate increases from the top to the bottom of this layer, but the extent of this increase diminishes as the depth increases. This is because deeper depths are less affected by tidal fluctuations in groundwater levels.</p></div>","PeriodicalId":55095,"journal":{"name":"Geothermics","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0375650524001391/pdfft?md5=62edd58cfd64a03e4767197d0a22e057&pid=1-s2.0-S0375650524001391-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geothermics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0375650524001391","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
Coastal regions undergo dynamic changes due to tidal forces, posing distinct challenges for groundwater management and utilization of ground source heat pump (GSHP) systems. This study examines the impact of tidal fluctuations on groundwater levels and the performance of ground heat exchangers (GHEs), specifically focusing on the suitability of horizontal directional drilling (HDD) technology in high-tidal zones. Itoman City in Okinawa Prefecture, Southern Japan, serves as an ideal location for this study due to its complex coastal hydrogeological conditions and increasing interest in renewable energy solutions. Employing a comprehensive approach involving field experiments, FEFLOW software simulations, and model validation, we aim to elucidate the intricate relationship between tidal dynamics, groundwater behavior, and GHE performance. Furthermore, our investigation assesses the effectiveness of HDD-GHEs installed in highly tidal-affected zones to determine the optimal installation depth for this type of GHE in coastal regions. According to our research, the layer at a depth of 30 m is most affected by tidal influence and fluctuations in groundwater levels in coastal regions. This layer is the most suitable for installing horizontal HDD-GHEs, with an average heat exchange rate of about 89 W/m. This rate is approximately four and two times higher than the depths above and below this layer, respectively, due to groundwater saturation and flow in the formation. Furthermore, we noticed that the heat exchange rate increases from the top to the bottom of this layer, but the extent of this increase diminishes as the depth increases. This is because deeper depths are less affected by tidal fluctuations in groundwater levels.
期刊介绍:
Geothermics is an international journal devoted to the research and development of geothermal energy. The International Board of Editors of Geothermics, which comprises specialists in the various aspects of geothermal resources, exploration and development, guarantees the balanced, comprehensive view of scientific and technological developments in this promising energy field.
It promulgates the state of the art and science of geothermal energy, its exploration and exploitation through a regular exchange of information from all parts of the world. The journal publishes articles dealing with the theory, exploration techniques and all aspects of the utilization of geothermal resources. Geothermics serves as the scientific house, or exchange medium, through which the growing community of geothermal specialists can provide and receive information.