Evaluation of consumer digital radon measurement devices: a comparative analysis.

IF 1.4 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES Journal of Radiological Protection Pub Date : 2024-05-24 DOI:10.1088/1361-6498/ad4bf1
Alexandra Bahadori, Brian Hanson
{"title":"Evaluation of consumer digital radon measurement devices: a comparative analysis.","authors":"Alexandra Bahadori, Brian Hanson","doi":"10.1088/1361-6498/ad4bf1","DOIUrl":null,"url":null,"abstract":"<p><p>Kansas State University (KSU) Engineering Extension conducted an abridged evaluation of eight consumer grade digital radon monitors. Using the KSU secondary radon chamber, these devices were exposed to three different radon concentrations for 7 d in average household temperature and relative humidity conditions. The three different radon concentration ranges used were: 12.8 pCi L<sup>-1</sup>to 15.5 pCi L<sup>-1</sup>(473.6 Bq m<sup>-3</sup>-573.5 Bq m<sup>-3</sup>), 27.7 pCi L<sup>-1</sup>to 29.4 pCi L<sup>-1</sup>(1024.9-10 857.8 Bq m<sup>-3</sup>), and ambient room level average radon concentration of 0.6 pCi L<sup>-1</sup>(22.2 Bq m<sup>-3</sup>). The American National Standards Institute/American Academy of Radon Scientists and Technologists Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air (ANSI/AARST MS-PC) (ANSI/AARST MS-PC 2022<i>Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air</i>(AARST Radon Standards)) minimum performance metrics were used to evaluate the accuracy and precision of each model type for each radon concentration tested. The eight different device models performed within the 0 ± 25% requirement for the individual percent error (IPE) for radon concentrations between 27.7 pCi L<sup>-1</sup>and 29.4 pCi L<sup>-1</sup>(1024.9-10 857.8 Bq m<sup>-3</sup>). For radon concentrations between 12.8 pCi L<sup>-1</sup>and 15.5 pCi L<sup>-1</sup>(444-592 Bq m<sup>-3</sup>) seven of the eight monitors fell within the IPE requirement and for ambient room radon concentrations six of the eight monitors fell within the IPE requirement for the ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022<i>Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air</i>(AARST Radon Standards)) ranges. All eight device models fell within the ± 15% ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022<i>Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air</i>(AARST Radon Standards)) coefficient of variation (CV) range for radon concentrations between 12.8 pCi L<sup>-1</sup>and 15.5 pCi L<sup>-1</sup>(444-592 Bq m<sup>-3</sup>) and for radon concentrations between 27.7 pCi L<sup>-1</sup>and 29.4 pCi L<sup>-1</sup>(1024.9-10 857.8 Bq m<sup>-3</sup>). In the future, evaluating the performance of these models over time to observe their long term accuracy and precision is anticipated.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad4bf1","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Kansas State University (KSU) Engineering Extension conducted an abridged evaluation of eight consumer grade digital radon monitors. Using the KSU secondary radon chamber, these devices were exposed to three different radon concentrations for 7 d in average household temperature and relative humidity conditions. The three different radon concentration ranges used were: 12.8 pCi L-1to 15.5 pCi L-1(473.6 Bq m-3-573.5 Bq m-3), 27.7 pCi L-1to 29.4 pCi L-1(1024.9-10 857.8 Bq m-3), and ambient room level average radon concentration of 0.6 pCi L-1(22.2 Bq m-3). The American National Standards Institute/American Academy of Radon Scientists and Technologists Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air (ANSI/AARST MS-PC) (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) minimum performance metrics were used to evaluate the accuracy and precision of each model type for each radon concentration tested. The eight different device models performed within the 0 ± 25% requirement for the individual percent error (IPE) for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). For radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) seven of the eight monitors fell within the IPE requirement and for ambient room radon concentrations six of the eight monitors fell within the IPE requirement for the ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) ranges. All eight device models fell within the ± 15% ANSI/AARST MS-PC minimum performance requirement (ANSI/AARST MS-PC 2022Performance Specifications for Instrumentation Systems Designed to Measure Radon Gas in Air(AARST Radon Standards)) coefficient of variation (CV) range for radon concentrations between 12.8 pCi L-1and 15.5 pCi L-1(444-592 Bq m-3) and for radon concentrations between 27.7 pCi L-1and 29.4 pCi L-1(1024.9-10 857.8 Bq m-3). In the future, evaluating the performance of these models over time to observe their long term accuracy and precision is anticipated.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
消费者数字氡测量设备的评估:比较分析。
堪萨斯州立大学 (KSU) 工程推广部门对八种消费级数字氡监测仪进行了简略评估。利用堪萨斯州立大学的二级氡室,在平均家庭温度和相对湿度条件下,将这些设备暴露在三种不同的氡浓度范围内 7 天。使用的三种不同氡浓度范围是12.8 pCi/L 至 15.5 pCi/L(473.6 Bq m-3-573.5 Bq m-3),27.7 pCi/L 至 29.4 pCi/L(1024.9 至 10857.8 Bq m-3),以及 0.6 pCi/L (22.2 Bq m-3)的室内环境水平平均氡浓度。美国国家标准学会/美国氡科学家和技术专家学会设计用于测量空气中氡气的仪器系统性能规范(ANSI/AARST MS-PC)[7] 最低性能指标被用来评估每种型号在每种氡浓度测试中的准确度和精确度。对于氡浓度介于 27.7 pCi/L 和 29.4 pCi/L(1024.9 至 10857.8 Bq m-3)之间的情况,八种不同设备型号的个别百分比误差 (IPE) 均在 0 ± 25% 的要求范围内。对于 12.8 pCi/L 至 15.5 pCi/L(444 至 592 Bq m-3)之间的氡浓度和室内环境氡浓度,八个监测仪中有七个在 IPE ANSI/AARST MS-PC 最低性能要求[7] 范围之内。对于氡浓度介于 12.8 pCi/L 和 15.5 pCi/L(444 至 592 Bq m-3)之间,以及氡浓度介于 27.7 pCi/L 和 29.4 pCi/L(1024.9 至 10857.8 Bq m-3)之间的情况,所有八个设备型号的变异系数 (CV) 都在 ± 15% ANSI/AARST MS-PC 最低性能要求 [7] 范围之内。今后,预计将对这些模型的性能进行长期评估,以观察其长期准确性和精确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Radiological Protection
Journal of Radiological Protection 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
2.60
自引率
26.70%
发文量
137
审稿时长
18-36 weeks
期刊介绍: Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments. The journal encourages publication of data and code as well as results.
期刊最新文献
Chronic bronchitis and bronchial asthma: the impact of chronic occupational radiation exposure on incidence and mortality of Mayak nuclear workers. Obituary for Professor Peter Cole. Factors associated with radiation risk perception among Japanese university students. What about the workers? An update. Book Review: Farr's physics for medical imaging (3rd edition).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1