The effect of orthodontic bracket base shape on shear bond strength to human enamel, an in vitro study

Ziana Esmail, William Wiltshire, Fabio H. S. L. Pinheiro, C. M. Frota, Rodrigo França
{"title":"The effect of orthodontic bracket base shape on shear bond strength to human enamel, an in vitro study","authors":"Ziana Esmail, William Wiltshire, Fabio H. S. L. Pinheiro, C. M. Frota, Rodrigo França","doi":"10.2340/biid.v11.40585","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to evaluate the in vitro effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel and assess the nature of debonding fractures using the Adhesive Remnant Index (ARI). Orthodontic brackets with different-shaped bases (flower, heart, rectangle) were bonded to 120 extracted human third molars. Shear bond strength was measured using a Servohydraulic Test System at 24 h and 2 months after bonding. Adhesive Remnant Index scores were evaluated under 10x magnification to assess the amount of resin left on the tooth. The control bracket (rectangular base shape) had the highest mean SBS (26.8 ± 8.2 megapascals [MPa]), and significantly differed from the flower (17.2 ± 4.4 MPa) and heart (18.9 ± 3.5 MPa) base shapes (p < 0.001). The mean SBS between debonding times at 24 h (21.5 ± 7.4 MPa) and 2 months (20.4 ± 6.7 MPa) were not statistically significant (p > 0.05). Analysis of ARI scores showed a significant difference between flower-24 h versus heart-2 months (p = 0.039), flower-24 h versus heart-24 h (p = 0.004), and control-2 months versus heart-24 h (p = 0.015). Bracket base shape influenced SBS, with the rectangular base shape having a higher mean SBS compared to flower and heart base shapes. Variations in ARI scores occurred based on bracket shape and were of a mixed adhesive-cohesive nature. All bracket shapes had bond strengths above the clinically acceptable range of 6–8 MPa, and may thus provide adequate SBS in a clinical situation. ","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2340/biid.v11.40585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study was to evaluate the in vitro effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel and assess the nature of debonding fractures using the Adhesive Remnant Index (ARI). Orthodontic brackets with different-shaped bases (flower, heart, rectangle) were bonded to 120 extracted human third molars. Shear bond strength was measured using a Servohydraulic Test System at 24 h and 2 months after bonding. Adhesive Remnant Index scores were evaluated under 10x magnification to assess the amount of resin left on the tooth. The control bracket (rectangular base shape) had the highest mean SBS (26.8 ± 8.2 megapascals [MPa]), and significantly differed from the flower (17.2 ± 4.4 MPa) and heart (18.9 ± 3.5 MPa) base shapes (p < 0.001). The mean SBS between debonding times at 24 h (21.5 ± 7.4 MPa) and 2 months (20.4 ± 6.7 MPa) were not statistically significant (p > 0.05). Analysis of ARI scores showed a significant difference between flower-24 h versus heart-2 months (p = 0.039), flower-24 h versus heart-24 h (p = 0.004), and control-2 months versus heart-24 h (p = 0.015). Bracket base shape influenced SBS, with the rectangular base shape having a higher mean SBS compared to flower and heart base shapes. Variations in ARI scores occurred based on bracket shape and were of a mixed adhesive-cohesive nature. All bracket shapes had bond strengths above the clinically acceptable range of 6–8 MPa, and may thus provide adequate SBS in a clinical situation. 
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正畸托槽基底形状对人体珐琅质剪切粘接强度的影响,体外研究
本研究旨在体外评估正畸托槽基底形状对人体珐琅质剪切粘结强度(SBS)的影响,并使用粘合剂残留指数(ARI)评估脱粘断裂的性质。在 120 颗拔出的人类第三磨牙上粘结了不同形状基托(花、心、矩形)的正畸托槽。粘结后 24 小时和 2 个月时,使用伺服液压测试系统测量剪切粘结强度。在 10 倍放大镜下评估粘合剂残留指数,以评估牙齿上残留的树脂量。对照托槽(矩形基底形状)的平均 SBS(26.8 ± 8.2 兆帕 [MPa])最高,与花形(17.2 ± 4.4 MPa)和心形(18.9 ± 3.5 MPa)基底形状有显著差异(p < 0.001)。24 小时(21.5 ± 7.4 兆帕)和 2 个月(20.4 ± 6.7 兆帕)脱粘时间之间的平均 SBS 没有统计学意义(p > 0.05)。对 ARI 分数的分析表明,花朵-24 小时与心脏-2 个月相比(p = 0.039)、花朵-24 小时与心脏-24 小时相比(p = 0.004)以及对照-2 个月与心脏-24 小时相比(p = 0.015)差异显著。支架底座形状对 SBS 有影响,矩形底座形状的平均 SBS 高于花形和心形底座形状的平均 SBS。支架形状不同,ARI 分数也不同,而且粘附性和粘合性参差不齐。所有支架形状的粘接强度都高于临床可接受的 6-8 兆帕的范围,因此在临床情况下可以提供足够的 SBS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
期刊最新文献
Recipient of Biomaterial Investigations in Dentistry's Young Author Award 2023. Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction. The sealing ability of different endodontic biomaterials as an intra-orifice barrier: evaluation with high-performance liquid chromatography. An in vitro study on the influence of laser-activated irrigation on infiltration and leakage of a dual curing-resin cement as an endodontic sealer Accumulation and removal of Streptococcus mutans biofilm on enamel and root surfaces in vitro
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1