{"title":"A meta-analysis of expressive prosody in cochlear implant users","authors":"Kara Hawthorne","doi":"10.1016/j.jcomdis.2024.106431","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Prosody is used to express indexical (identifying the talker), linguistic (e.g., question intonation, lexical stress), pragmatic (e.g., contrastive stress, sarcasm), and emotional/affective functions. It is manifested through changes in fundamental frequency (<em>f</em><sub>0</sub>), intensity, and duration. <em>F</em><sub>0</sub> and intensity are degraded when perceived through a cochlear implant (CI). The purpose of this meta-analysis is to compare expressive prosody in speech produced by CI users versus normal hearing peers.</p></div><div><h3>Methods</h3><p>A systematic search of the literature found 25 articles that met all inclusion criteria. These articles were assessed for quality, and data pertaining to the expression of <em>f</em><sub>0</sub>, intensity, and duration, as well as classification accuracy and appropriateness ratings from normal hearing listeners, were extracted and meta-analyzed using random effects models.</p></div><div><h3>Results</h3><p>The articles included in the meta-analysis were generally of acceptable or high quality. Meta-analyses revealed significant differences between individuals with CIs vs. normal hearing on all measures except mean <em>f</em><sub>0</sub>, mean intensity, and rhythm. Effect sizes were generally medium to large. There was significant heterogeneity across studies, but little evidence of publication bias.</p></div><div><h3>Conclusions</h3><p>CI users speak with less variable <em>f</em><sub>0</sub>, smaller <em>f</em><sub>0</sub> contours, more variable intensity, a slower speech rate, and reduced final lengthening at syntactic boundaries. These acoustic differences are reflected in significantly poorer ratings of speech produced by CI users compared to their normal hearing peers, as assessed by groups of normal hearing listeners. Because atypical expressive prosody is associated with negative outcomes, clinicians should consider targeting prosody when working with individuals who use CIs.</p></div>","PeriodicalId":49175,"journal":{"name":"Journal of Communication Disorders","volume":"110 ","pages":"Article 106431"},"PeriodicalIF":1.8000,"publicationDate":"2024-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Communication Disorders","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021992424000273","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Prosody is used to express indexical (identifying the talker), linguistic (e.g., question intonation, lexical stress), pragmatic (e.g., contrastive stress, sarcasm), and emotional/affective functions. It is manifested through changes in fundamental frequency (f0), intensity, and duration. F0 and intensity are degraded when perceived through a cochlear implant (CI). The purpose of this meta-analysis is to compare expressive prosody in speech produced by CI users versus normal hearing peers.
Methods
A systematic search of the literature found 25 articles that met all inclusion criteria. These articles were assessed for quality, and data pertaining to the expression of f0, intensity, and duration, as well as classification accuracy and appropriateness ratings from normal hearing listeners, were extracted and meta-analyzed using random effects models.
Results
The articles included in the meta-analysis were generally of acceptable or high quality. Meta-analyses revealed significant differences between individuals with CIs vs. normal hearing on all measures except mean f0, mean intensity, and rhythm. Effect sizes were generally medium to large. There was significant heterogeneity across studies, but little evidence of publication bias.
Conclusions
CI users speak with less variable f0, smaller f0 contours, more variable intensity, a slower speech rate, and reduced final lengthening at syntactic boundaries. These acoustic differences are reflected in significantly poorer ratings of speech produced by CI users compared to their normal hearing peers, as assessed by groups of normal hearing listeners. Because atypical expressive prosody is associated with negative outcomes, clinicians should consider targeting prosody when working with individuals who use CIs.
期刊介绍:
The Journal of Communication Disorders publishes original articles on topics related to disorders of speech, language and hearing. Authors are encouraged to submit reports of experimental or descriptive investigations (research articles), review articles, tutorials or discussion papers, or letters to the editor ("short communications"). Please note that we do not accept case studies unless they conform to the principles of single-subject experimental design. Special issues are published periodically on timely and clinically relevant topics.